Model-Based Reconstruction for Real-Time Phase-Contrast Flow MRI: Improved Spatiotemporal Accuracy

被引:32
作者
Tan, Zhengguo [1 ]
Roeloffs, Volkert [1 ]
Voit, Dirk [1 ]
Joseph, Arun A. [1 ,2 ]
Untenberger, Markus [1 ]
Merboldt, K. Dietmar [1 ]
Frahm, Jens [1 ,2 ]
机构
[1] Biomed NMR Forsch GmbH, Max Planck Inst Biophys Chem, D-37070 Gottingen, Germany
[2] German Ctr Cardiovasc Res, DZHK, Partner Site Gottingen, Berlin, Germany
关键词
nonlinear inverse reconstruction; model-based reconstruction; cardiovascular blood flow; phase-contrast flow MRI; radial MRI; real-time MRI; NONLINEAR INVERSE RECONSTRUCTION; SPIN-ECHO MRI; CARDIOVASCULAR MAGNETIC-RESONANCE; IMAGE-RECONSTRUCTION; RADIAL FLASH; RESOLUTION; VELOCITY; SENSE; MS;
D O I
10.1002/mrm.26192
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a model-based reconstruction technique for real-time phase-contrast flow MRI with improved spatiotemporal accuracy in comparison to methods using phase differences of two separately reconstructed images with differential flow encodings. Methods: The proposed method jointly computes a common image, a phase-contrast map, and a set of coil sensitivities from every pair of flow-compensated and flow-encoded datasets obtained by highly undersampled radial FLASH. Real-time acquisitions with five and seven radial spokes per image resulted in 25.6 and 35.7 ms measuring time per phase-contrast map, respectively. The signal model for phase-contrast flow MRI requires the solution of a nonlinear inverse problem, which is accomplished by an iteratively regularized Gauss-Newton method. Aspects of regularization and scaling are discussed. The model-based reconstruction was validated for a numerical and experimental flow phantom and applied to real-time phase-contrast MRI of the human aorta for 10 healthy subjects and 2 patients. Results: Under all conditions, and compared with a previously developed real-time flow MRI method, the proposed method yields quantitatively accurate phase-contrast maps (i.e., flow velocities) with improved spatial acuity, reduced phase noise and reduced streaking artifacts. Conclusion: This novel model-based reconstruction technique may become a new tool for clinical flow MRI in real time. (C) 2016 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1082 / 1093
页数:12
相关论文
共 37 条
  • [1] [Anonymous], 1996, REGULARIZATION INVER
  • [2] [Anonymous], 2004, HDB MRI PULSE SEQUEN, DOI 10.1016/B978-0-12-092861-3.X5000-6
  • [3] Bakushinsky AB, 2004, Iterative Methods for Approximate solution of Inverse Problems
  • [4] Accelerating cine phase-contrast flow measurements using k-t BLAST and k-t SENSE
    Baltes, C
    Kozerke, S
    Hansen, MS
    Pruessmann, KP
    Tsao, J
    Boesiger, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) : 1430 - 1438
  • [5] Model-Based Iterative Reconstruction for Radial Fast Spin-Echo MRI
    Block, Kai Tobias
    Uecker, Martin
    Frahm, Jens
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) : 1759 - 1769
  • [6] MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE
    BRYANT, DJ
    PAYNE, JA
    FIRMIN, DN
    LONGMORE, DB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) : 588 - 593
  • [7] Chitiboi T, 2014, I S BIOMED IMAGING, P943, DOI 10.1109/ISBI.2014.6868027
  • [8] Model-Based Image Reconstruction for MRI
    Fessler, Jeffrey A.
    [J]. IEEE SIGNAL PROCESSING MAGAZINE, 2010, 27 (04) : 81 - 89
  • [9] Applications of phase-contrast flow and velocity imaging in cardiovascular MRI
    Gatehouse, PD
    Keegan, J
    Crowe, LA
    Masood, S
    Mohiaddin, RH
    Kreitner, KF
    Firmin, DN
    [J]. EUROPEAN RADIOLOGY, 2005, 15 (10) : 2172 - 2184
  • [10] Realistic Analytical Phantoms for Parallel Magnetic Resonance Imaging
    Guerquin-Kern, M.
    Lejeune, L.
    Pruessmann, K. P.
    Unser, M.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (03) : 626 - 636