Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with 15O-H2O PET

被引:80
作者
Kikuchi, Yasuka [1 ]
Oyama-Manabe, Noriko [1 ]
Naya, Masanao [2 ]
Manabe, Osamu [3 ]
Tomiyama, Yuuki [3 ]
Sasaki, Tsukasa [4 ]
Katoh, Chietsugu [5 ]
Kudo, Kohsuke [1 ]
Tamaki, Nagara [3 ]
Shirato, Hiroki [6 ]
机构
[1] Hokkaido Univ Hosp, Dept Diagnost & Intervent Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Dept Cardiovasc Med, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Grad Sch Med, Dept Nucl Med, Sapporo, Hokkaido, Japan
[4] Hokkaido Univ Hosp, Dept Radiol, Sapporo, Hokkaido 0608638, Japan
[5] Hokkaido Univ, Fac Hlth Sci, Sapporo, Hokkaido, Japan
[6] Hokkaido Univ, Grad Sch Med, Dept Radiat Med, Sapporo, Hokkaido, Japan
关键词
MDCT; Cardiac; Perfusion; Myocardium blood flow; Coronary flow reserve; TRANSTHORACIC DOPPLER-ECHOCARDIOGRAPHY; CORONARY-ARTERY-DISEASE; POSITRON-EMISSION-TOMOGRAPHY; COMPUTED-TOMOGRAPHY; DIAGNOSTIC PERFORMANCE; CORE320; MULTICENTER; VELOCITY RESERVE; DOSE REDUCTION; VOLUME CT; PERFUSION;
D O I
10.1007/s00330-014-3164-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against O-15-H2O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P < 0.0001). CFR showed good correlation between dynamic CTP and PET (r = 0.67, P = 0.0126). CFRCT in the CAD group (2.3 +/- 0.8) was significantly lower than that in the validation group (5.2 +/- 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. aEuro cent MBF and CFR can be calculated using dynamic CTP with 320-row MDCT. aEuro cent MBF and CFR showed good correlation between dynamic CTP and PET. aEuro cent Lower CFR was well demonstrated in CAD patients by dynamic CTP.
引用
收藏
页码:1547 / 1556
页数:10
相关论文
共 35 条
[1]   Direct Comparison of Cardiac Magnetic Resonance and Multidetector Computed Tomography Stress-Rest Perfusion Imaging for Detection of Coronary Artery Disease [J].
Bettencourt, Nuno ;
Chiribiri, Amedeo ;
Schuster, Andreas ;
Ferreira, Nuno ;
Sampaio, Francisco ;
Pires-Morais, Gustavo ;
Santos, Lino ;
Melica, Bruno ;
Rodrigues, Alberto ;
Braga, Pedro ;
Azevedo, Luis ;
Teixeira, Madalena ;
Leite-Moreira, Adelino ;
Silva-Cardoso, Jose ;
Nagel, Eike ;
Gama, Vasco .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) :1099-1107
[2]   Medical progress - Coronary microvascular dysfunction [J].
Camici, Paolo G. ;
Crea, Filippo .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (08) :830-840
[3]   Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose [J].
Chen, Chien-Ming ;
Chu, Sung-Yu ;
Hsu, Ming-Yi ;
Liao, Ying-Lan ;
Tsai, Hui-Yu .
EUROPEAN RADIOLOGY, 2014, 24 (02) :460-468
[4]   Submillisievert Median Radiation Dose for Coronary Angiography with a Second-Generation 320-Detector Row CT Scanner in 107 Consecutive Patients [J].
Chen, Marcus Y. ;
Shanbhag, Sujata M. ;
Arai, Andrew E. .
RADIOLOGY, 2013, 267 (01) :76-85
[5]  
Cousins C., 2013, Annals of the ICRP, V42, P9, DOI 10.1016/j.icrp.2012.09.001
[6]   PERMEABILITY OF CAPILLARIES IN VARIOUS ORGANS AS DETERMINED BY USE OF INDICATOR DIFFUSION METHOD [J].
CRONE, C .
ACTA PHYSIOLOGICA SCANDINAVICA, 1963, 58 (04) :292-&
[7]   Physiologic assessment of coronary artery stenosis by coronary flow reserve measurements with transthoracic Doppler echocardiography: Comparison with exercise thallium-201 single-photon emission computed tomography [J].
Daimon, M ;
Watanabe, H ;
Yamagishi, H ;
Muro, T ;
Akioka, K ;
Hirata, K ;
Takeuchi, K ;
Yoshikawa, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) :1310-1315
[8]   Will 3-dimensional PET-CT enable the routine quantification of myocardial blood flow? [J].
dekemp, Robert A. ;
Yoshinaga, Keiichiro ;
Beanlands, Rob S. B. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (03) :380-397
[9]   Dose reduction in dynamic CT stress myocardial perfusion imaging: comparison of 80-kV/370-mAs and 100-kV/300-mAs protocols [J].
Fujita, Makiko ;
Kitagawa, Kakuya ;
Ito, Tatsuro ;
Shiraishi, Yasuyuki ;
Kurobe, Yusuke ;
Nagata, Motonori ;
Ishida, Masaki ;
Sakuma, Hajime .
EUROPEAN RADIOLOGY, 2014, 24 (03) :748-755
[10]   Altered myocardial flow reserve and endothelial function late after Kawasaki disease [J].
Furuyama, H ;
Odagawa, Y ;
Katoh, C ;
Iwado, Y ;
Ito, Y ;
Noriyasu, K ;
Mabuchi, M ;
Yoshinaga, K ;
Kuge, Y ;
Kobayashi, K ;
Tamaki, N .
JOURNAL OF PEDIATRICS, 2003, 142 (02) :149-154