Posterior Mini-Incision With Primary Total Hip Arthroplasty: A Nine to Ten Year Follow Up Study

被引:14
|
作者
Yukizawa, Yohei [1 ]
Dorr, Lawrence D. [1 ]
Ward, Jeri A. [1 ]
Wan, Zhinian [1 ]
机构
[1] Univ So Calif, Keck Med Ctr, Dept Orthoped Surg, Los Angeles, CA 90033 USA
来源
JOURNAL OF ARTHROPLASTY | 2016年 / 31卷 / 01期
关键词
posterior mini-incision; short incision; standard incision; ten year results; wear; imageless computer navigation; CROSS-LINKED POLYETHYLENE; ANTERIOR APPROACH; REPLACEMENT; DISLOCATION; STANDARD; COMPONENT; WEAR; THA;
D O I
10.1016/j.arth.2015.07.023
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The question has been raised as to whether small incision surgery will compromise long term results of total hip arthroplasty. We report nine to ten years' outcome with posterior mini-incision. Radiographs were measured for component position, polyethylene wear, fixation, and osteolysis. Sixty-two of the original 86 patients (76 of 100 hips) were alive and available for study with 17 patients deceased (with known results) and seven (8%) lost to follow-up. The result was rated as excellent in 70 of 75 remaining hips (93%). Eighty-nine of 93 hips (96%) with known results had the original implants. Radiographically, wear was a mean 0.015 +/- 0.009 mm/year, and no hip had impending failure. There were four revisions, 2 for dislocation, 1 for fracture, and 1 for loose cup. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:168 / 171
页数:4
相关论文
共 50 条
  • [41] Total knee arthroplasties performed with a mini-incision or a standard incision. Similar results at six months follow-up
    Hernandez-Vaquero, Daniel
    Noriega-Fernandez, Alfonso
    Suarez-Vazquez, Abelardo
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [42] Total knee arthroplasties performed with a mini-incision or a standard incision. Similar results at six months follow-up
    Daniel Hernandez-Vaquero
    Alfonso Noriega-Fernandez
    Abelardo Suarez-Vazquez
    BMC Musculoskeletal Disorders, 11
  • [43] The effect of the "mini" incision in total hip arthroplasty on component position
    Teet, Jaroslava Svoboda
    Skinner, Harry B.
    Khoury, Loren
    JOURNAL OF ARTHROPLASTY, 2006, 21 (04): : 503 - 507
  • [44] Total hip arthroplasty with use of the cementless Zweymuller alloclassic system - A ten to thirteen-year follow-up study
    Garcia-Cimbrelo, E
    Cruz-Pardos, A
    Madero, R
    Ortega-Andreu, M
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (02): : 296 - 303
  • [45] Mini-incision versus mini-incision and computer-assisted surgery in total knee replacement: A radiological prospective randomised study
    Confalonieni, Norberto
    Manzotti, Alfonso
    Pullen, Chris
    Ragone, Vincenza
    KNEE, 2007, 14 (06): : 443 - 447
  • [46] Total hip arthroplasty with an uncemented femoral component - Excellent results at ten-year follow-up
    McLaughlin, JR
    Lee, KR
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (06): : 900 - 907
  • [47] The mini postero-postero-lateral mini incision in total hip arthroplasty
    Jacquot, Frederic
    Mokhtar, Mokrane Ait
    Sautet, Alain
    Doursounian, Levon
    Masquelet, Alain-Charles
    Feron, Jean-Marc
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (10) : 1891 - 1895
  • [48] The mini postero-postero-lateral mini incision in total hip arthroplasty
    Frederic Jacquot
    Mokrane Ait Mokhtar
    Alain Sautet
    Levon Doursounian
    Alain-Charles Masquelet
    Jean-Marc Feron
    International Orthopaedics, 2013, 37 : 1891 - 1895
  • [49] Little Clinical Advantage of Modified Watson-Jones Approach Over Modified Mini-Incision Direct Lateral Approach in Primary Total Hip Arthroplasty
    Inaba, Yutaka
    Kobayashi, Naomi
    Yukizawa, Yohei
    Ishida, Takashi
    Iwamoto, Naoyuki
    Saito, Tomoyuki
    JOURNAL OF ARTHROPLASTY, 2011, 26 (07): : 1117 - 1122
  • [50] Mini-incision total knee arthroplasty can increase risk of component malalignment - Reply
    Dalury, David F.
    Dennis, Douglas A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (449) : 320 - 320