Mid-Term Results After Sternal Reconstruction Using Titanium Plates: Is It Worth It to Plate?

被引:9
作者
Voss, Stephanie
Will, Albrecht
Lange, Ruediger
Voss, Bernhard
机构
[1] Tech Univ Munich, German Heart Ctr Munich, Dept Cardiovasc Surg, Munich, Germany
[2] Tech Univ Munich, German Heart Ctr Munich, Dept Cardiovasc Surg, Insure Inst Translat Cardiac Surg, Munich, Germany
[3] Tech Univ Munich, German Heart Ctr Munich, Dept Radiol, Munich, Germany
关键词
MEDIAN STERNOTOMY; CARDIAC-SURGERY; WOUND-INFECTION; THORACIC-SURGERY; RIGID FIXATION; RISK-FACTORS; CHEST-PAIN; FOLLOW-UP; DEHISCENCE; CLOSURE;
D O I
10.1016/j.athoracsur.2018.01.057
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Sternal dehiscence after median sternotomy is a challenging problem in situations of frail bone, fractures, or complete sternectomy. Plate osteosynthesis offers a promising approach to restore sternal integrity. However, there is only scarce data on mid-term outcome. Methods. Mid-term data on 34 patients with unstable thorax after open heart operation, requiring sternal refixation with the Synthes Titanium Sternal Fixation System (Oberdorf, Switzerland) between 2005 and 2011, were analyzed. The Titanium Sternal Fixation System was used if conventional rewiring had failed or if failure of rewiring was expected because of risk factors. Follow-up examinations included clinical tests, computed tomographic scans, and pain assessment to evaluate sternal integrity and persistent pain. Results. Median follow-up time was 1.4 years (range, 0.3 to 6.6 years). Clinical examination showed thoracic stability in all patients. Computed tomographic scans demonstrated complete bone consolidation in 25.8%, nearly complete in 38.7%, partial in 9.7%, and missing in 25.8% of patients. Pain assessment revealed no sternal pain in 16 patients (48.5%), mild pain in 9 (27.3%), moderate pain in 3 (9.1%), and severe pain in 5 patients (15.1%). Pain on movement was reported in 12 patients and 5 patients had chronic pain. A total of 13 patients (38%) required plate removal due to pain (n = 8) or infection (n = 5) after a median of 10.9 and 2 months, respectively. Conclusions. With the use of plates, it was possible to achieve thoracic stabilization in complicated dehiscence. However, the rate of postoperative infection and pain is not negligible. Thus, we recommend plate reconstruction only in sternal high-risk patients, who are unsuitable for standard reclosure. (C) 2018 by The Society of Thoracic Surgeons
引用
收藏
页码:1640 / 1647
页数:8
相关论文
共 34 条
  • [11] Transverse sternal plating in secondary sternal reconstruction
    Huh, Joseph
    Bakaeen, Faisal
    Chu, Danny
    Wall, Matthew J., Jr.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 136 (06) : 1476 - 1480
  • [12] PAIN AFTER THORACIC-SURGERY
    KALSO, E
    PERTTUNEN, K
    KAASINEN, S
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1992, 36 (01) : 96 - 100
  • [13] STERNAL WOUND COMPLICATIONS AFTER ISOLATED CORONARY-ARTERY BYPASS-GRAFTING - EARLY AND LATE MORTALITY, MORBIDITY, AND COST OF CARE
    LOOP, FD
    LYTLE, BW
    COSGROVE, DM
    MAHFOOD, S
    MCHENRY, MC
    GOORMASTIC, M
    STEWART, RW
    GOLDING, LAR
    TAYLOR, PC
    [J]. ANNALS OF THORACIC SURGERY, 1990, 49 (02) : 179 - 187
  • [14] Primary closure of median sternotomy: techniques and principles
    Losanoff, JE
    Jones, JW
    Richman, BW
    [J]. CARDIOVASCULAR SURGERY, 2002, 10 (02): : 102 - 110
  • [15] Disruption and infection of median sternotomy: a comprehensive review
    Losanoff, JE
    Richman, BW
    Jones, JW
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 21 (05) : 831 - 839
  • [16] Chest wall resections and reconstruction: A 25-year experience
    Mansour, KA
    Thourani, VH
    Losken, A
    Reeves, JG
    Miller, JI
    Carlson, GW
    Jones, GE
    [J]. ANNALS OF THORACIC SURGERY, 2002, 73 (06) : 1720 - 1725
  • [17] Pain location, distribution, and intensity after cardiac surgery
    Mueller, XM
    Tinguely, F
    Tevaearai, HT
    Revelly, JP
    Chioléro, R
    von Segesser, LK
    [J]. CHEST, 2000, 118 (02) : 391 - 396
  • [18] Biomechanical study of sternal closure using rigid fixation techniques in human cadavers
    Ozaki, W
    Buchman, SR
    Iannettoni, MD
    Frankenburg, EP
    [J]. ANNALS OF THORACIC SURGERY, 1998, 65 (06) : 1660 - 1665
  • [19] In vitro comparison of wire and plate fixation for midline sternotomies
    Pai, S
    Gunja, NJ
    Dupak, EL
    McMahon, NL
    Roth, TP
    Lalikos, JF
    Dunn, RM
    Francalancia, N
    Pins, GD
    Billiar, KL
    [J]. ANNALS OF THORACIC SURGERY, 2005, 80 (03) : 962 - 968
  • [20] Chest Wall Reconstruction Using Sternal Plating in Patients With Complex Sternal Dehiscence
    Pancholy, Bharat
    Raman, Jai
    [J]. ANNALS OF THORACIC SURGERY, 2015, 99 (06) : 2228 - 2230