PRETREATMENT METHOD RESEARCH OF NEAR-INFRARED SPECTRA IN BLOOD COMPONENT NON-INVASIVE MEASUREMENT

被引:7
作者
Li, Li Na [1 ]
Zhang, Guang Jun [1 ]
Li, Qing Bo [1 ]
机构
[1] Beihang Univ, Precis Optomech Technol Key Lab Educ Minist, Beijing 100083, Peoples R China
来源
MODERN PHYSICS LETTERS B | 2009年 / 23卷 / 07期
关键词
Near-infrared spectroscopy; pretreatment; wavelet; blood component; non-invasive; UNINFORMATIVE VARIABLE ELIMINATION; CONTINUOUS WAVELET TRANSFORM; MULTIVARIATE CALIBRATION; SPECTROSCOPY; FOURIER;
D O I
10.1142/S0217984909019065
中图分类号
O59 [应用物理学];
学科分类号
摘要
Blood component non-invasive measurement based on near-infrared (NIR) spectroscopy has become a favorite topic in the field of biomedicine. However, the various noises from instrument measurement and the varying background from absorption of other components (except target analyte) in blood are the main causes, which influenced the prediction accuracy of multivariable calibration. Thinking of backgrounds and noises are always found in high-scale approximation and low-scale detail coefficients. It is possible to identify them by wavelet transform (WT), which has multi-resolution trait and can break spectral signals into different frequency components retaining the same resolution as the original signal. Meanwhile, associating with a criterion of uninformative variable elimination (UVE), it is better to eliminate backgrounds and noises simultaneously and visually. Basic principle and application technology of this pretreatment method, wavelet transform with UVE criterion, were presented in this paper. Three experimental near-infrared spectra data sets, including aqueous solution with four components data sets, plasma data sets, body oral glucose tolerance test (OGTT) data sets, which, including glucose (the target analyte in this study), have all been used in this paper as examples to explain this pretreatment method. The effect of selected wavelength bands in the pretreatment process were discussed, and then the adaptability of different pretreatment method for the uncertainty complex NIR spectra model in blood component non-invasive measurements were also analyzed. This research indicates that the pretreatment methods of wavelet transform with UVE criterion can be used to eliminate varying backgrounds and noises for experimental NIR spectra data directly. Under the spectra area of 1100 to 1700 nm, utilizing this pretreatment method is helpful for us to get a more simple and higher precision multivariable calibration for blood glucose non-invasive measurement. Furthermore, by comparing with some other pretreatment methods, the results imply that the method applied in this study has more adaptability for the complex NIR spectra model. This study gives us another path for improving the blood component non-invasive measurement technique based on NIR spectroscopy.
引用
收藏
页码:925 / 937
页数:13
相关论文
共 21 条
  • [1] [Anonymous], SHANGHAI J BIOMEDICA
  • [2] Burmeister J J, 2000, Diabetes Technol Ther, V2, P5, DOI 10.1089/152091500316683
  • [3] A variable selection method based on uninformative variable elimination for multivariate calibration of near-infrared spectra
    Cai, Wensheng
    Li, Yankun
    Shao, Xueguang
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2008, 90 (02) : 188 - 194
  • [4] Elimination of uninformative variables for multivariate calibration
    Centner, V
    Massart, DL
    deNoord, OE
    deJong, S
    Vandeginste, BM
    Sterna, C
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (21) : 3851 - 3858
  • [5] A Background and noise elimination method for quantitative calibration of near infrared spectra
    Chen, D
    Shao, XG
    Hu, B
    Su, QD
    [J]. ANALYTICA CHIMICA ACTA, 2004, 511 (01) : 37 - 45
  • [6] An application of derivative and continuous wavelet transforms to the overlapping ratio spectra for the quantitative multiresolution of a ternary mixture of paracetamol, acetylsalicylic acid and caffeine in tablets
    Dinç, E
    Özdemir, A
    Baleanu, D
    [J]. TALANTA, 2005, 65 (01) : 36 - 47
  • [7] Ding J. R., 1990, Modern Physics Letters B, V4, P1111, DOI 10.1142/S0217984990001409
  • [8] Quantification of components in overlapping peaks from capillary electrophoresis by using continues wavelet transform method
    Jiao, Long
    Gao, Suya
    Zhang, Fang
    Li, Hua
    [J]. TALANTA, 2008, 75 (04) : 1061 - 1067
  • [9] Application of wavelet transform to extract the relevant component from spectral data for multivariate calibration
    JouanRimbaud, D
    Walczak, B
    Poppi, RJ
    deNoord, OE
    Massart, DL
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (21) : 4317 - 4323
  • [10] Maximum spectrum of continuous wavelet transform and its application in resolving an overlapped signal
    Lu, XQ
    Liu, HD
    Xue, ZH
    Zhang, Q
    [J]. JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 2004, 44 (04): : 1228 - 1237