Mini-beam collimator enables microcrystallography experiments on standard beamlines

被引:71
作者
Fischetti, Robert F. [1 ]
Xu, Shenglan [1 ]
Yoder, Derek W. [1 ]
Becker, Michael [1 ]
Nagarajan, Venugopalan [1 ]
Sanishvili, Ruslan [1 ]
Hilgart, Mark C. [1 ]
Stepanov, Sergey [1 ]
Makarov, Oleg [1 ]
Smith, Janet L. [1 ,2 ]
机构
[1] Argonne Natl Lab, Adv Photon Source, GM CA CAT, Biosci Div, Argonne, IL 60439 USA
[2] Univ Michigan, Dept Biol Chem, Inst Life Sci, Ann Arbor, MI 48109 USA
关键词
mini-beam; microbeam; microdiffraction; macromolecular crystallography; PROTEIN-COUPLED RECEPTOR; CRYSTAL-STRUCTURE; SYNCHROTRON-RADIATION; CRYSTALLOGRAPHY; MICRODIFFRACTION;
D O I
10.1107/S0909049508040612
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The high-brilliance X-ray beams from undulator sources at third-generation synchrotron facilities are excellent tools for solving crystal structures of important and challenging biological macromolecules and complexes. However, many of the most important structural targets yield crystals that are too small or too inhomogeneous for a 'standard' beam from an undulator source, similar to 25-50 mu m (FWHM) in the vertical and 50-100 mu m in the horizontal direction. Although many synchrotron facilities have microfocus beamlines for other applications, this capability for macromolecular crystallography was pioneered at ID-13 of the ESRF. The National Institute of General Medical Sciences and National Cancer Institute Collaborative Access Team (GM/CA-CAT) dual canted undulator beamlines at the APS deliver high-intensity focused beams with a minimum focal size of 20 mu m x 65 mu m at the sample position. To meet growing user demand for beams to study samples of 10 mu m or less, a 'mini-beam' apparatus was developed that conditions the focused beam to either 5 mu m or 10 mu m (FWHM) diameter with high intensity. The mini-beam has a symmetric Gaussian shape in both the horizontal and vertical directions, and reduces the vertical divergence of the focused beam by 25%. Significant reduction in background was achieved by implementation of both forward- and back-scatter guards. A unique triple-collimator apparatus, which has been in routine use on both undulator beamlines since February 2008, allows users to rapidly interchange the focused beam and conditioned mini-beams of two sizes with a single mouse click. The device and the beam are stable over many hours of routine operation. The rapid-exchange capability has greatly facilitated sample screening and resulted in several structures that could not have been obtained with the larger focused beam.
引用
收藏
页码:217 / 225
页数:9
相关论文
共 29 条
[1]   High-resolution crystal structure of an engineered human β2-adrenergic G protein-coupled receptor [J].
Cherezov, Vadim ;
Rosenbaum, Daniel M. ;
Hanson, Michael A. ;
Rasmussen, Soren G. F. ;
Thian, Foon Sun ;
Kobilka, Tong Sun ;
Choi, Hee-Jung ;
Kuhn, Peter ;
Weis, William I. ;
Kobilka, Brian K. ;
Stevens, Raymond C. .
SCIENCE, 2007, 318 (5854) :1258-1265
[2]  
CIPRIANI F, 2007, 9 INT C SYNCHR RAD I, P1928
[3]   The molecular organization of cypovirus polyhedra [J].
Coulibaly, Fasseli ;
Chiu, Elaine ;
Ikeda, Keiko ;
Gutmann, Sascha ;
Haebel, Peter W. ;
Schulze-Briese, Clemens ;
Mori, Hajime ;
Metcalf, Peter .
NATURE, 2007, 446 (7131) :97-101
[4]  
DECKER G, 2005, P 2005 PART ACC C KN, P3268
[5]   The crystal structure of tetanus toxin Hc fragment complexed with a synthetic GT1b analogue suggests cross-linking between ganglioside receptors and the toxin [J].
Fotinou, C ;
Emsley, P ;
Black, I ;
Ando, H ;
Ishida, H ;
Kiso, M ;
Sinha, KA ;
Fairweather, NF ;
Isaacs, NW .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2001, 276 (34) :32274-32281
[6]   An optimal exposure strategy for cryoprotected virus crystals with lattice constants greater than 1000Å [J].
Gan, Lu ;
Johnson, John E. .
JOURNAL OF SYNCHROTRON RADIATION, 2008, 15 :223-226
[7]   Single-bounce monocapillaries for focusing synchrotron radiation: modeling, measurements and theoretical limits [J].
Huang, R ;
Bilderback, DH .
JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 :74-84
[8]   Structural basis for translation termination on the 70S ribosome [J].
Laurberg, Martin ;
Asahara, Haruichi ;
Korostelev, Andrei ;
Zhu, Jianyu ;
Trakhanov, Sergei ;
Noller, Harry F. .
NATURE, 2008, 454 (7206) :852-857
[9]   Blu-Ice and the Distributed Control System:: software for data acquisition and instrument control at macromolecular crystallography beamlines [J].
McPhillips, TM ;
McPhillips, SE ;
Chiu, HJ ;
Cohen, AE ;
Deacon, AM ;
Ellis, PJ ;
Garman, E ;
Gonzalez, A ;
Sauter, NK ;
Phizackerley, RP ;
Soltis, SM ;
Kuhn, P .
JOURNAL OF SYNCHROTRON RADIATION, 2002, 9 :401-406
[10]   Protein crystallography with a micrometre-sized synchrotron-radiation beam [J].
Moukhametzianov, Rouslan ;
Burghammer, Manfred ;
Edwards, Patricia C. ;
Petitdemange, Sebastien ;
Popov, Dimitri ;
Fransen, Maikel ;
McMullan, Gregory ;
Schertler, Gebhard F. X. ;
Riekel, Christian .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2008, 64 :158-166