Automatic anatomy recognition in whole-body PET/CT images

被引:18
|
作者
Wang, Huiqian [1 ,2 ]
Udupa, Jayaram K. [2 ]
Odhner, Dewey [2 ]
Tong, Yubing [2 ]
Zhao, Liming [2 ,3 ]
Torigian, Drew A. [2 ]
机构
[1] Chongqing Univ, Coll Optoelect Engn, Chongqing 400044, Peoples R China
[2] Univ Penn, Dept Radiol, Med Image Proc Grp, Philadelphia, PA 19104 USA
[3] Chongqing Univ Posts & Telecommun, Res Ctr Intelligent Syst & Robot, Chongqing 400065, Peoples R China
关键词
image segmentation; PET/CT imaging; object recognition; texture; fuzzy models; POSITRON-EMISSION-TOMOGRAPHY; 3D CT IMAGES; THRESHOLD SEGMENTATION; REGRESSION FORESTS; NECK-CANCER; LOCALIZATION; HEAD; CLASSIFICATION; DELINEATION; SYSTEM;
D O I
10.1118/1.4939127
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., "Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images," Med. Image Anal. 18, 752-771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process, to bring performance to the level achieved on diagnostic CT and MR images in body-region-wise approaches. The intermodality approach fosters the use of already existing fuzzy models, previously created from diagnostic CT images, on PET/CT and other derived images, thus truly separating the modality-independent object assembly anatomy from modality-specific tissue property portrayal in the image. Results: Key ways of combining the above three basic ideas lead them to 15 different strategies for recognizing objects in PET/CT images. Utilizing 50 diagnostic CT image data sets from the thoracic and abdominal body regions and 16 whole-body PET/CT image data sets, the authors compare the recognition performance among these 15 strategies on 18 objects from the thorax, abdomen, and pelvis in object localization error and size estimation error. Particularly on texture membership images, object localization is within three voxels on whole-body low-dose CT images and 2 voxels on body-region-wise low-dose images of known true locations. Surprisingly, even on direct body-region-wise PET images, localization error within 3 voxels seems possible. Conclusions: The previous body-region-wise approach can be extended to whole-body torso with similar object localization performance. Combined use of image texture and intensity property yields the best object localization accuracy. In both body-region-wise and whole-body approaches, recognition performance on low-dose CT images reaches levels previously achieved on diagnostic CT images. The best object recognition strategy varies among objects; the proposed framework however allows employing a strategy that is optimal for each object. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:613 / 629
页数:17
相关论文
共 50 条
  • [1] Automatic bone segmentation in whole-body CT images
    André Klein
    Jan Warszawski
    Jens Hillengaß
    Klaus H. Maier-Hein
    International Journal of Computer Assisted Radiology and Surgery, 2019, 14 : 21 - 29
  • [2] Automatic bone segmentation in whole-body CT images
    Klein, Andre
    Warszawski, Jan
    Hillengass, Jens
    Maier-Hein, Klaus H.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2019, 14 (01) : 21 - 29
  • [3] Body-wide Anatomy Recognition in PET/CT Images
    Wang, Huiqian
    Udupa, Jayaram K.
    Odhner, Dewey
    Tong, Yubing
    Zhao, Liming
    Torigian, Drew A.
    MEDICAL IMAGING 2015: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2015, 9415
  • [4] Automatic tumour delineation in whole body PET/CT images
    Huang, Xiaolei
    Zhu, Yaoyao
    Li, Hongsheng
    Guan, Haiying
    Potesil, Vaclav
    Song, Yulin
    Kubota, Toshiro
    Zhou, Xiang Sean
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 8 (2-3) : 182 - 199
  • [5] Improved Alignment of PET and CT Images in Whole-Body PET/CT in Cases of Respiratory Motion During CT
    Hamill, James J.
    Meier, Joseph G.
    Cuellar, Sonia L. Betancourt
    Sabloff, Bradley
    Erasmus, Jeremy J.
    Mawlawi, Osama
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (09) : 1376 - 1380
  • [6] Whole-body PET angiography on semiconductor PET/CT
    Norikane, Takashi
    Yamamoto, Yuka
    Takami, Yasukage
    Mitamura, Katsuya
    Matsumoto, Keisuke
    Maeda, Yukito
    Yamashita, Yoichi
    Nishiyama, Yoshihiro
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (02) : 885 - 888
  • [7] Whole-body PET angiography on semiconductor PET/CT
    Takashi Norikane
    Yuka Yamamoto
    Yasukage Takami
    Katsuya Mitamura
    Keisuke Matsumoto
    Yukito Maeda
    Yoichi Yamashita
    Yoshihiro Nishiyama
    Journal of Nuclear Cardiology, 2022, 29 : 885 - 888
  • [8] Diagnostic accuracy of whole-body PET/MRI and whole-body PET/CT for TNM staging in oncology
    Philipp Heusch
    Felix Nensa
    Benedikt Schaarschmidt
    Rupika Sivanesapillai
    Karsten Beiderwellen
    Benedikt Gomez
    Jens Köhler
    Henning Reis
    Verena Ruhlmann
    Christian Buchbender
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 42 - 48
  • [9] Diagnostic accuracy of whole-body PET/MRI and whole-body PET/CT for TNM staging in oncology
    Heusch, Philipp
    Nensa, Felix
    Schaarschmidt, Benedikt
    Sivanesapillai, Rupika
    Beiderwellen, Karsten
    Gomez, Benedikt
    Koehler, Jens
    Reis, Henning
    Ruhlmann, Verena
    Buchbender, Christian
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (01) : 42 - 48
  • [10] Automatic Anatomy Recognition on CT Images with Pathology
    Huang, Lidong
    Udupa, Jayaram K.
    Tong, Yubing
    Odhner, Dewey
    Torigian, Drew A.
    MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS, 2015, 9785