Simultaneous voltammetry detection of dopamine and uric acid in human serum and urine with a poly(procaterol hydrochloride) modified glassy carbon electrode

被引:36
作者
Kong, Dexian [1 ,2 ]
Zhuang, Qizhao [1 ]
Han, Yejian [1 ]
Xu, Lanping [1 ]
Wang, Zeming [1 ]
Jiang, Lili [2 ]
Su, Jinwei [1 ]
Lu, Chun-Hua [2 ]
Chi, Yuwu [2 ]
机构
[1] Fujian Agr & Forestry Univ, Coll Life Sci, Fuzhou 350002, Fujian, Peoples R China
[2] Fuzhou Univ, Coll Chem, Fuzhou 350108, Fujian, Peoples R China
关键词
Poly(procaterol hydrochloride); Dopamine; Uric acid; Electrochemical; Biological samples; ASCORBIC-ACID; ELECTROCHEMICAL SENSOR; CAPILLARY-ELECTROPHORESIS; LIQUID-CHROMATOGRAPHY; OXIDE NANOCOMPOSITE; SELECTIVE DETECTION; PASTE ELECTRODE; NANOPARTICLES; FACILE; GOLD;
D O I
10.1016/j.talanta.2018.03.078
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present study, procaterol hydrochloride (ProH) was successfully electropolymerized onto a glass carbon electrode (GCE) with simply cyclic voltammetry scans to construct a poly(procaterol hydrochloride) (p-ProH) membrane modified electrode. Compared with the bare GCE, much higher oxidation peak current responses and better peak potentials separation could be obtained for the simultaneous oxidation of dopamine (DA) and uric acid (UA), owning to the excellent electrocatalytic ability of the p-ProH membrane. And it's based on that a square wave voltammetry (SWV) method was developed to selective and simultaneous measurement of DA and UA. Under the optimum conditions, the linear dependence of oxidation peak current on analyte concentrations were found to be 1.0-100 mu mol/L and 2-100 mu mol/L, giving detection limits of 0.3 mu mol/L and 0.5 mu mol/L for DA and UA, separately. The as prepared modified electrode shows simplicity in construction with the merits of good reproducibility, high stability, passable selectivity and nice sensitivity. Finally, the proposed p-ProH membrane modified electrode was successfully devoted to the detection of DA and UA in biological fluids such as human serum and urine with acceptable results.
引用
收藏
页码:203 / 212
页数:10
相关论文
共 55 条
[1]  
Bard A. J., 1980, ELECTROCHEMICAL METH
[2]   Determination of L-ascorbic acid in human serum by chemiluminescence based on hydrogen peroxide-sodium hydrogen carbonate-CdSe/CdS quantum dots system [J].
Chen, Hui ;
Li, Ruibo ;
Lin, Ling ;
Guo, Guangsheng ;
Lin, Jin-Ming .
TALANTA, 2010, 81 (4-5) :1688-1696
[3]  
Chen T, 1987, J Pharm Sci, V76, P703, DOI 10.1002/jps.2600760907
[4]   A facile water-stable MOF-based "off-on'' fluorescent switch for label-free detection of dopamine in biological fluid [J].
Cheng, Yue ;
Wu, Jie ;
Guo, Chao ;
Li, Xin-Ge ;
Ding, Bin ;
Li, Yan .
JOURNAL OF MATERIALS CHEMISTRY B, 2017, 5 (13) :2524-2535
[5]   Advanced nanomaterial inks for screen-printed chemical sensors [J].
Chu, Zhenyu ;
Peng, Jingmeng ;
Jin, Wanqin .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 :919-926
[6]   On the electrochemistry of dopamine in aqueous solution. Part I: The role of [SDS] on the voltammetric behavior of dopamine on a carbon paste electrode [J].
Corona-Avendano, Silvia ;
Alarcon-Angeles, Georgina ;
Ramirez-Silva, Maria Teresa ;
Rosquete-Pina, Giselle ;
Romero-Romo, Mario ;
Palomar-Pardave, Manuel .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 609 (01) :17-26
[7]   Functionalised carbon nano spheres modified electrode for simultaneous determination of dopamine and uric acid [J].
Dey, Milan Kumar ;
Satpati, Ashis Kumar .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 787 :95-102
[8]   In situ electrochemical synthesis of reduced graphene oxide-cobalt oxide nanocomposite modified electrode for selective sensing of depression biomarker in the presence of ascorbic acid and dopamine [J].
Dinesh, Bose ;
Veeramani, Vediyappan ;
Chen, Shen-Ming ;
Saraswathi, Ramiah .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 786 :169-176
[9]   Highly selective determination of ascorbic acid, dopamine, and uric acid by differential pulse voltammetry using poly(sulfonazo III) modified glassy carbon electrode [J].
Ensafi, Ali A. ;
Taei, M. ;
Khayamian, T. ;
Arabzadeh, A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 147 (01) :213-221
[10]   Simultaneous electrochemical determination of ascorbic acid and uric acid using poly(glyoxal-bis(2-hydroxyanil)) modified glassy carbon electrode [J].
Ergun, Eser ;
Kart, Serife ;
Zeybek, Derya Koyuncu ;
Zeybek, Bulent .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 224 :55-64