Validation of reconstructed bremsstrahlung spectra between 6 MV and 25 MV from measured transmission data

被引:20
作者
Francois, P
Coste, F
Bonnet, J
Caselles, O
机构
[1] Centre Claudius Regaud, Unité de Physique, 31052 Toulouse
关键词
high energy x-ray spectra; transmission curve; narrow beam; spectral reconstruction; ENERGY PHOTON BEAMS; NUMERIC SYSTEM AF=T; X-RAY-BEAMS; DIRECT RESOLUTION; DOSE DATA; COMPONENT; QUALITY; RATIO;
D O I
10.1118/1.597998
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have previously investigated a method of high-energy x-ray spectral reconstruction from transmission data by direct resolution of a matrix system. This technique uses the spectral vectorial algebra formalism. The resolution has previously been tested on a 12 MV photon beam. To extend and to test the validity of the results to the entire radiotherapy energy range, we have performed the method on photon beams with nominal energies of 6, 12, 15, and 25 MV. The influence on the 6 MV spectrum of a 60 degrees built-in wedge has also been investigated to test the sensitivity of the method and the results are reported. To validate our reconstructed spectra, dosimetric quantities such as tissue phantom ratios (TPR), water-to-air stopping power ratios (S/rho)(air)(water), and quality indexes TPR1020 have been calculated. The results show good agreement between the measured and calculata data. Mean mass energy absorption coefficient ratios for different materials have also been computed and compared to data published recently and the results are very close (within +/-0.5%). Primary depth dose functions in water have also been computed to deduce primary dose attenuation coefficients. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:769 / 773
页数:5
相关论文
共 18 条
[1]   STOPPING-POWER RATIO FOR A PHOTON SPECTRUM AS A WEIGHTED SUM OF THE VALUES FOR MONOENERGETIC PHOTON BEAMS [J].
ANDREO, P ;
NAHUM, AE .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (10) :1055-1065
[2]  
[Anonymous], 1980, ACTA RADIOL ONCOL
[3]   CHARACTERISTICS OF CONTAMINATION ELECTRONS IN HIGH-ENERGY PHOTON BEAMS [J].
BEAUVAIS, H ;
BRIDIER, A ;
DUTREIX, A .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (03) :308-316
[4]  
BJARNGARD BE, 1994, MED PHYS, V21, P1069, DOI 10.1118/1.597349
[5]   DESCRIPTION OF THE SCATTER COMPONENT IN PHOTON-BEAM DATA [J].
BJARNGARD, BE ;
PETTI, PL .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01) :21-32
[6]   RECONSTRUCTION OF 12-MV BREMSSTRAHLUNG SPECTRA FROM MEASURED TRANSMISSION DATA BY DIRECT RESOLUTION OF THE NUMERIC SYSTEM AF=T [J].
CATALA, A ;
FRANCOIS, P ;
BONNET, J ;
SCOUARNEC, C .
MEDICAL PHYSICS, 1995, 22 (01) :3-10
[7]   SIMULATION OF X-RAY SPECTRAL RECONSTRUCTION FROM TRANSMISSION DATA BY DIRECT RESOLUTION OF THE NUMERIC SYSTEM AF=T [J].
FRANCOIS, P ;
CATALA, A ;
SCOUARNEC, C .
MEDICAL PHYSICS, 1993, 20 (06) :1695-1703
[8]  
FROBERG CE, 1965, INTRO NUMERICAL ANAL, P176
[9]   MEAN MASS-ENERGY ABSORPTION-COEFFICIENT RATIOS FOR MEGAVOLTAGE X-RAY-BEAMS [J].
FURHANG, EE ;
CHUI, CS ;
LOVELOCK, M .
MEDICAL PHYSICS, 1995, 22 (05) :525-530
[10]   RECONSTRUCTION OF 4-MV BREMSSTRAHLUNG SPECTRA FROM MEASURED TRANSMISSION DATA [J].
HUANG, PH ;
KASE, KR ;
BJARNGARD, BE .
MEDICAL PHYSICS, 1983, 10 (06) :778-785