Complementarity of ultrasound and fluorescence imaging in an orthotopic mouse model of pancreatic cancer

被引:35
作者
Snyder, Cynthia S. [1 ]
Kaushal, Sharmeela [1 ]
Kono, Yuko [2 ]
Cao, Hop S. Tran [3 ]
Hoffman, Robert M. [3 ,4 ]
Bouvet, Michael [1 ,3 ]
机构
[1] Univ Calif San Diego, Moores UCSD Canc Ctr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Med, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Dept Surg, La Jolla, CA 92093 USA
[4] AntiCancer Inc, San Diego, CA USA
基金
美国国家卫生研究院;
关键词
PROTEINS; MICE;
D O I
10.1186/1471-2407-9-106
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Pancreatic cancer is a devastating disease characterized by dismal 5-year survival rates and limited treatment options. In an effort to provide useful models for preclinical evaluation of new experimental therapeutics, we and others have developed orthotopic mouse models of pancreatic cancer. The utility of these models for pre-clinical testing is dependent upon quantitative, noninvasive methods for monitoring in vivo tumor progression in real time. Toward this goal, we performed whole-body fluorescence imaging and ultrasound imaging to evaluate and to compare these noninvasive imaging modalities for assessing tumor burden and tumor progression in an orthotopic mouse model of pancreatic cancer. Methods: The human pancreatic cancer cell line XPA-1, engineered for stable, high-level expression of red fluorescent protein (RFP), was implanted into the pancreas of nude mice using orthotopic implantation. The tumors were allowed to grow over a period of one to several weeks during which time the mice were imaged using both fluorescence imaging and ultrasound imaging to measure tumor burden and to monitor tumor growth. Results: Whole-body fluorescence imaging and ultrasound imaging both allowed for the visualization and measurement of orthotopic pancreatic tumor implants in vivo. The imaging sessions were well-tolerated by the mice and yielded data which correlated well in the quantitative assessment of tumor burden. Whole-body fluorescence and two-dimensional ultrasound imaging showed a strong correlation for measurement of tumor size over a range of tumor sizes (R-2 = 0.6627, P = 0.003 for an exposure time of 67 msec and R-2 = 0.6553, P = 0.003 for an exposure time of 120 msec). Conclusion: Our findings suggest a complementary role for fluorescence imaging and ultrasound imaging in assessing tumor burden and tumor progression in orthotopic mouse models of human cancer.
引用
收藏
页数:10
相关论文
共 14 条
[1]   High correlation of whole-body red fluorescent protein imaging and magnetic resonance imaging on an orthotopic model of pancreatic cancer [J].
Bouvet, M ;
Spernyak, J ;
Katz, MH ;
Mazurchuk, RV ;
Takimoto, S ;
Bernacki, R ;
Rustum, YM ;
Moossa, AR ;
Hoffman, RM .
CANCER RESEARCH, 2005, 65 (21) :9829-9833
[2]   Chronologically-specific metastatic targeting of human pancreatic tumors in orthotopic models [J].
Bouvet, M ;
Yang, M ;
Nardin, S ;
Wang, X ;
Jiang, P ;
Baranov, E ;
Moossa, AR ;
Hoffman, RM .
CLINICAL & EXPERIMENTAL METASTASIS, 2000, 18 (03) :213-218
[3]  
Bouvet M, 2002, CANCER RES, V62, P1534
[4]  
Bruns Christiane J., 1999, Neoplasia (New York), V1, P50, DOI 10.1038/sj.neo.7900005
[5]   A METASTATIC NUDE-MOUSE MODEL OF HUMAN PANCREATIC-CANCER CONSTRUCTED ORTHOTOPICALLY WITH HISTOLOGICALLY INTACT PATIENT SPECIMENS [J].
FU, XY ;
GUADAGNI, F ;
HOFFMAN, RM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (12) :5645-5649
[6]   In vivo cell biology of cancer cells visualized with fluorescent proteins [J].
Hoffman, RM .
CURRENT TOPICS IN DEVELOPMENTAL BIOLOGY, VOLUME 70, 2005, 70 :121-+
[7]   Whole-body imaging with fluorescent proteins [J].
Hoffman, Robert M. ;
Yang, Meng .
NATURE PROTOCOLS, 2006, 1 (03) :1429-1438
[8]   Cancer statistics, 2008 [J].
Jemal, Ahmedin ;
Siegel, Rebecca ;
Ward, Elizabeth ;
Hao, Yongping ;
Xu, Jiaquan ;
Murray, Taylor ;
Thun, Michael J. .
CA-A CANCER JOURNAL FOR CLINICIANS, 2008, 58 (02) :71-96
[9]   A novel red fluorescent protein orthotopic pancreatic cancer model for the preclinical evaluation of chemotherapeutics [J].
Katz, MH ;
Takimoto, S ;
Spivack, D ;
Moossa, AR ;
Hoffman, RM ;
Bouvet, M .
JOURNAL OF SURGICAL RESEARCH, 2003, 113 (01) :151-160
[10]   Ovarian volume measurements in mice with high-resolution ultrasonography [J].
Lyshchik, Andrej ;
Hobbs, Stephen B. ;
Fleischer, Arthur C. ;
Khabele, Dineo ;
Son, Deok-Soo ;
Gore, John C. ;
Price, Ronald R. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (10) :1419-1425