Electrodeposited antimony and antimony-gold nanocomposite modified carbon paste electrodes for the determination of heavy metal ions

被引:17
|
作者
Dey, M. K. [1 ]
Satpati, A. K. [1 ]
Reddy, A. V. R. [1 ]
机构
[1] Bhabha Atom Res Ctr, Div Analyt Chem, Bombay 40085, Maharashtra, India
关键词
ANODIC-STRIPPING VOLTAMMETRY; BISMUTH-FILM ELECTRODES; TRACE NICKEL; CADMIUM(II); LEAD(II); INSIGHTS; MERCURY;
D O I
10.1039/c4ay00876f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Antimony (Sb) film was electrodeposited on the surface of a carbon paste electrode (CPE) for the determination of heavy metal ions such as Cd, Pb and Cu. An ex situ analytical method based on this Sb film modified CPE was proposed for the determination of heavy metal ions. While the deposition of the Sb film was performed in a 0.02 M HCl solution, the determination of heavy metal ions was performed in a sodium acetate medium. For the determination of Cu, the pH of the solution was the most crucial factor and was optimised to a value of 6. For the determination of Hg, an antimony and gold nanocomposite (Sb-Au nanocomposite) was co-deposited over the surface of a carbon paste electrode. The modified electrodes were characterised using SEM and EDS measurements. The SEM measurements of Sb-Au nanocomposites show a dendrimer type of morphology. The three sigma detection limits of Pb, Cd, Cu and Hg were determined to be 2.65, 2.32, 9.73, and 0.052 mu g L-1, respectively. Finally, the method was applied for the determination of Cd, Pb, Cu and Hg in real water samples.
引用
收藏
页码:5207 / 5213
页数:7
相关论文
共 50 条
  • [11] Individual and Simultaneous Determination of Heavy Metal Ions Using Carbon Paste Electrode Modified with Titania Nanoparticles
    Elif Tüzün
    Gülten Atun
    Electrocatalysis, 2023, 14 : 636 - 647
  • [12] Biomass-modified carbon paste electrodes for monitoring dissolved metal ions
    Yao, H
    Ramelow, GJ
    TALANTA, 1998, 45 (06) : 1139 - 1146
  • [13] Determination of trace antimony (III) by adsorption voltammetry at carbon paste electrode
    Guo, HS
    Li, YH
    Chen, XK
    Nie, LB
    He, NY
    SENSORS, 2005, 5 (4-5) : 284 - 292
  • [14] ALCOHOL DETERMINATION BY MODIFIED CARBON PASTE ELECTRODES
    BILITEWSKI, U
    SCHMID, RD
    BIOSENSORS : APPLICATIONS IN MEDICINE, ENVIRONMENTAL PROTECTION AND PROCESS CONTROL, 1989, 13 : 99 - 102
  • [15] Antimony nanoparticle-multiwalled carbon nanotubes composite immobilized at carbon paste electrode for determination of trace heavy metals
    Ashrafi, Amir M.
    Cerovac, Sandra
    Mudric, Sanja
    Guzsvany, Valeria
    Husakova, Lenka
    Urbanova, Iva
    Vytras, Karel
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 : 320 - 325
  • [16] A graphene/ionic liquid modified selenium-doped carbon paste electrode for determination of copper and antimony
    Liu, Rong
    Lei, Cunxi
    Zhong, Tongsheng
    Long, Liping
    Wu, Zhaoyang
    Huan, Shuangyan
    Zhang, Qi
    ANALYTICAL METHODS, 2016, 8 (05) : 1120 - 1126
  • [17] New procedures for voltammetric determination of copper (II) using antimony film-coated carbon paste electrodes
    Ashrafi, Amir M.
    Vytras, Karel
    ELECTROCHIMICA ACTA, 2012, 73 : 112 - 117
  • [18] Flower-like hydroxyapatite modified carbon paste electrodes applicable for highly sensitive detection of heavy metal ions
    Zhang, Ying
    Liu, Yong
    Ji, Xiaobo
    Banks, Craig E.
    Zhang, Wei
    JOURNAL OF MATERIALS CHEMISTRY, 2011, 21 (21) : 7552 - 7554
  • [19] Electrodeposited Bi-Au nanocomposite modified carbon paste electrode for the simultaneous determination of copper and mercury
    Sahoo, S.
    Satpati, A. K.
    Reddy, A. V. R.
    RSC ADVANCES, 2015, 5 (33) : 25794 - 25800
  • [20] APPLICATION OF LICHEN-MODIFIED CARBON PASTE ELECTRODES TO THE VOLTAMMETRIC DETERMINATION OF METAL-IONS IN MULTIELEMENT AND SPECIATION STUDIES
    DEMPSEY, E
    SMYTH, MR
    RICHARDSON, DHS
    ANALYST, 1992, 117 (09) : 1467 - 1470