Simple protein precipitation extraction technique followed by validated chromatographic method for linezolid analysis in real human plasma samples to study its pharmacokinetics

被引:16
作者
Mohammed, Samah A. [1 ]
Eissa, Maya S. [2 ]
Ahmed, Hytham M. [3 ]
机构
[1] Natl Org Drug Control & Res, Giza, Egypt
[2] Egyptian Russian Univ, Dept Analyt Chem, Fac Pharm, Cairo, Egypt
[3] Damanhour Univ, Dept Pharmaceut Anal, Fac Pharm, Damanhour, Egypt
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2017年 / 1043卷
关键词
Linezolid; HPLC; Human plasma; Protein precipitation; Pharmacokinetic study; PERFORMANCE LIQUID-CHROMATOGRAPHY; HUMAN SERUM; ULTRAVIOLET DETECTION; BRONCHOALVEOLAR LAVAGE; ASSAY; FIBERS; URINE; BLOOD; MS;
D O I
10.1016/j.jchromb.2016.09.042
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fast and sensitive HPLC method was developed, optimized and validated for quantification of linezolid (LNZ) in human plasma using guaifenesin as an internal standard (IS). Analyte and IS were extracted from plasma by simple protein precipitation extraction technique using methanol as the precipitating solvent. The pretreated samples were injected in a mobile phase formed of acetonitrile:water:methanol (20:70:10 v/v/v) in an isocratic mode at a flow rate of 1.5 mL/min with UV detection at 251 nm. Separation was done using Aglient ODS C-18. The method showed linearity in the range of 0.75-50 mu g/mL with correlation coefficients equals to 0.9991. Precision and accuracy were in conformity with the criteria normally accepted in bio-analytical method validation. The RSDs for intra- and inter-day assays were <3.56 and 4.63%, respectively. The intra- and inter-day accuracies were 94.67-98.28% and 91.25-96.18%, respectively. The mean absolute recoveries ranged from 92.56 +/- 1.78 to 95.24 +/- 2.84. According to stability results, LNZ was stable in human plasma during the storage and analysis. LNZ a pharmacokinetic behavior was studied by applying the proposed analytical method. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:235 / 240
页数:6
相关论文
共 36 条
[1]  
[Anonymous], 2001, GUID IND BIOAN METH
[2]   High-performance liquid chromatographic method for simple and rapid determination of linezolid in human plasma [J].
Boak, Lauren M. ;
Li, Jian ;
Nation, Roger L. ;
Rayner, Craig R. .
BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (08) :782-786
[3]   Determination of linezolid in human serum and urine by high-performance liquid chromatography [J].
Borner, K ;
Borner, E ;
Lode, H .
INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2001, 18 (03) :253-258
[4]   Development of a liquid chromatography method for the determination of linezolid and its application to in vitro and human microdialysis samples [J].
Buerger, C ;
Joukhadar, C ;
Muller, M ;
Kloft, C .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (01) :155-164
[5]   Determination of Linezolid in Human Plasma by High-Performance Liquid Chromatography With Ultraviolet Detection [J].
Cattaneo, Dario ;
Baldelli, Sara ;
Conti, Francesca ;
Cozzi, Valeria ;
Clementi, Emilio .
THERAPEUTIC DRUG MONITORING, 2010, 32 (04) :520-524
[6]  
Cios A, 2013, ACTA POL PHARM, V70, P631
[7]   Linezolid [J].
Clemett, D ;
Markham, A .
DRUGS, 2000, 59 (04) :815-827
[8]   An adaptable HPLC method for the analysis of frequently used antibiotics in ocular samples [J].
Davis, Lindsay T. ;
Kumar, Neeru ;
Nijm, Lisa M. ;
Ulanski, Lawrence J., II ;
Tu, Elmer Y. ;
Fiscella, Richard G. ;
Peterson, Randal J. ;
Glickman, Randolph D. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (26) :2421-2426
[9]   A new and rapid method for monitoring the new oxazolidinone antibiotic linezolid in serum and urine by high performance liquid chromatography-integrated sample preparation [J].
Ehrlich, M ;
Trittler, R ;
Daschner, FD ;
Kümmerer, K .
JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2) :373-377
[10]   Validation of a new HPLC-UV method for determination of the antibiotic linezolid in human plasma and in bronchoalveolar lavage [J].
Fortuna, Serena ;
De Pascale, Gennaro ;
Ragazzoni, Enzo ;
Antonelli, Massimo ;
Navarra, Pierluigi .
BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (11) :1489-1496