Gluteal tendon repair augmented with a synthetic ligament: surgical technique and a case series

被引:34
作者
Bucher, Thomas A. [1 ]
Darcy, Peter [2 ]
Ebert, Jay R. [3 ]
Smith, Anne [4 ,5 ]
Janes, Greg [6 ]
机构
[1] Royal Devon & Exeter Hosp, Princess Elizabeth Orthopaed Ctr, Exeter EX2 5DW, Devon, England
[2] George Eliot Hosp, Dept Orthopaed, Nuneaton, Warwick, England
[3] Univ Western Australia, Sch Sport Sci Exercise & Hlth, Nedlands, WA 6009, Australia
[4] Sch Physiotherapy, Perth, WA, Australia
[5] Curtin Hlth Innovat Res Inst, Perth, WA, Australia
[6] Perth Orthopaed & Sports Med Ctr, Perth, WA, Australia
关键词
GTPS; Gluteal tendinopathy; Synthetic ligament; Abductor tear; TROCHANTERIC PAIN SYNDROME; ROTATOR-CUFF TEAR; ILIOTIBIAL BAND; HIP; MEDIUS; DIAGNOSIS; ANATOMY;
D O I
10.5301/hipint.5000093
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We describe an augmented surgical repair technique for gluteus minimus and medius tears, along with a supportive case series. A consecutive series of 22 patients presenting with clinical and radiological findings consistent with hip abductor tears, who had undergone failed prior conservative treatments, were prospectively recruited. Patients underwent open bursectomy, Y-iliotibial release, debridement of the diseased tendon, decortication of the trochanteric foot-plate and reattachment augmented with a LARS ligament through a trans-osseous tunnel, together with suture anchors. All patients were assessed pre- and postoperatively to 12 months with the Oxford Hip Score (OHS), the Short-Form Health Survey (SF-36) and a Visual Analogue Pain Scale (VAS), while a satisfaction scale was employed at 12 months. A statistically significant improvement (p<0.05) was observed for all patient reported outcome measures, while all patients were at least 'satisfied' with the procedure at 12 months. One patient reported some lateral hip discomfort at 10 months, and removal of the LARS interference screw provided immediate relief. One patient had a urological catheter-related complication. With no other complications and no clinical failures of the repair, we believe the technique to be safe and reliable, whilst reducing the incidence of re-tears as reported in the existing literature.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 25 条
[1]   Gluteal tendon reconstruction in association with hip arthroplasty [J].
Bajwa, Ali S. ;
Middleton, Fionna ;
Campbell, David G. ;
Comely, Andrew S. ;
Lewis, Peter L. .
HIP INTERNATIONAL, 2011, 21 (03) :288-292
[2]   Treatment of recurrent dislocation of total hip arthroplasty using a ligament prosthesis [J].
Barbosa, JK ;
Khan, AM ;
Andrew, JG .
JOURNAL OF ARTHROPLASTY, 2004, 19 (03) :318-321
[3]  
Bird PA, 2001, ARTHRITIS RHEUM, V44, P2138, DOI 10.1002/1529-0131(200109)44:9<2138::AID-ART367>3.0.CO
[4]  
2-M
[5]   Rotator-cuff tear of the hip [J].
Bunker, TD ;
Esler, CNA ;
Leach, WJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (04) :618-620
[6]   Z-lengthening of the iliotibial band to treat recalcitrant cases of trochanteric bursitis [J].
Chirputkar, K. ;
Weir, P. ;
Gray, A. .
HIP INTERNATIONAL, 2007, 17 (01) :31-35
[7]  
Cohen J., 1988, Statistical power analysis for the behavioral sciences, VSecond
[8]   Iliotibial band z-lengthening for refractory trochanteric bursitis (greater trochanteric pain syndrome) [J].
Craig, Roy A. ;
Jones, David P. Gwynne ;
Oakley, Andrew P. ;
Dunbar, John D. .
ANZ JOURNAL OF SURGERY, 2007, 77 (11) :996-998
[9]   MRI diagnosis of tears of the hip abductor tendons (gluteus medius and gluteus minimus) [J].
Cvitanic, O ;
Henzie, G ;
Skezas, N ;
Lyons, J ;
Minter, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (01) :137-143
[10]  
Davies H, 2009, HIP INT, V19, P372