Synergy Effect of Nanocrystalline Cellulose for the Biosensing Detection of Glucose

被引:64
作者
Esmaeili, Chakavak [1 ]
Abdi, Mahnaz M. [2 ,3 ]
Mathew, Aji P. [4 ]
Jonoobi, Mehdi [5 ]
Oksman, Kristiina [4 ]
Rezayi, Majid [6 ]
机构
[1] Univ Kebangsaan Malaysia, Sch Chem Sci & Food Technol, Fac Sci & Technol, Bangi 43600, Malaysia
[2] Univ Putra Malaysia, Dept Chem, Fac Sci, Serdang 43400, Malaysia
[3] Univ Putra Malaysia, Inst Trop Forestry & Forest Prod, Serdang 43400, Malaysia
[4] Lulea Univ Technol, Div Mat Sci, Composite Ctr Sweden, S-97187 Lulea, Sweden
[5] Univ Tehran, Fac Nat Resources, Dept Wood & Paper Sci & Technol, Karaj 3158777871, Iran
[6] Univ Malaya, Dept Chem, Fac Sci, Kuala Lumpur 50603, Malaysia
关键词
glucose biosensor; cellulose nanocrystals; GOx; PPy-CNC nanocomposite; chemical polymerization; direct electrochemistry; MULTIWALL CARBON NANOTUBES; CONDUCTOMETRIC BIOSENSOR; SOL-GEL; OXIDASE; POLYPYRROLE; COMPOSITE; IMMOBILIZATION; NANOPARTICLES; GRAPHENE; ENZYME;
D O I
10.3390/s151024681
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Integrating polypyrrole-cellulose nanocrystal-based composites with glucose oxidase (GOx) as a new sensing regime was investigated. Polypyrrole-cellulose nanocrystal (PPy-CNC)-based composite as a novel immobilization membrane with unique physicochemical properties was found to enhance biosensor performance. Field emission scanning electron microscopy (FESEM) images showed that fibers were nanosized and porous, which is appropriate for accommodating enzymes and increasing electron transfer kinetics. The voltammetric results showed that the native structure and biocatalytic activity of GOx immobilized on the PPy-CNC nanocomposite remained and exhibited a high sensitivity (ca. 0.73 AmM-1), with a high dynamic response ranging from 1.0 to 20 mM glucose. The modified glucose biosensor exhibits a limit of detection (LOD) of (50 +/- 10) mu M and also excludes interfering species, such as ascorbic acid, uric acid, and cholesterol, which makes this sensor suitable for glucose determination in real samples. This sensor displays an acceptable reproducibility and stability over time. The current response was maintained over 95% of the initial value after 17 days, and the current difference measurement obtained using different electrodes provided a relative standard deviation (RSD) of 4.47%.
引用
收藏
页码:24681 / 24697
页数:17
相关论文
共 60 条
[1]  
Abdi M.M., 2014, HDB GREEN MAT PROCES
[2]   Surface Plasmon Resonance Sensing Detection of Mercury and Lead Ions Based on Conducting Polymer Composite [J].
Abdi, Mahnaz M. ;
Abdullah, Luqman Chuah ;
Sadrolhosseini, Amir R. ;
Yunus, Wan Mahmood Mat ;
Moksin, Mohd Maarof ;
Tahir, Paridah Md .
PLOS ONE, 2011, 6 (09)
[3]   High-performance glucose sensor based on glucose oxidase encapsulated in new synthesized platinum nanoparticles supported on carbon Vulcan/Nafion composite deposited on glassy carbon [J].
Ammam, Malika ;
Easton, E. Bradley .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 155 (01) :340-346
[4]   Optimization of the isolation of nanocrystals from microcrystalline cellulose by acid hydrolysis [J].
Bondeson, D ;
Mathew, A ;
Oksman, K .
CELLULOSE, 2006, 13 (02) :171-180
[5]  
Brânzoi V, 2009, REV ROUM CHIM, V54, P783
[6]   One-step fabrication of biocompatible carboxymethyl cellulose polymeric particles for drug delivery systems [J].
Butun, Sultan ;
Ince, Fatma Gul ;
Erdugan, Huseyin ;
Sahiner, Nurettin .
CARBOHYDRATE POLYMERS, 2011, 86 (02) :636-643
[7]   Glucose concentration determination based on silica sol-gel encapsulated glucose oxidase optical biosensor arrays [J].
Chang, Gang ;
Tatsu, Yoshiro ;
Goto, Tatsushi ;
Imaishi, Hiromasa ;
Morigaki, Kenichi .
TALANTA, 2010, 83 (01) :61-65
[8]  
Chen S.-S., 2000, Kirk-Othmer Encyclopedia of Chemical Technology
[9]  
Cunningham D.D., 2009, Vivo Glucose Sensing
[10]   POLYPYRROLE POLY(VINYL CHLORIDE) AND POLYPYRROLE CELLULOSE-ACETATE CONDUCTING COMPOSITE FILMS BY OPPOSITE-DIFFUSION POLYMERIZATION [J].
DUBITSKY, YA ;
ZHUBANOV, BA .
SYNTHETIC METALS, 1993, 53 (03) :303-307