Effects of Novel Collector Roof on Solar Chimney Power Plant Performance

被引:13
作者
Elwekeel, Fifi N. M. [1 ]
Abdala, Antar M. M. [2 ]
Rahman, Muhammad Mustafizur [3 ]
机构
[1] Helwan Univ, Fac Ind Educ, Cairo 11813, Egypt
[2] Helwan Univ, Fac Engn, Matareya Branch, Cairo 11718, Egypt
[3] Wichita State Univ, Dept Mech Engn, Wichita, KS 67260 USA
来源
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME | 2019年 / 141卷 / 03期
关键词
collector roof; solar chimney; power plant; grooves; GEOMETRIC PARAMETERS; SIMULATION;
D O I
10.1115/1.4041403
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The effects of collector roughness shape on the performance of solar chimney power plant were investigated in this study. The roughness shapes of triangular, curved, and square grooves were chosen and were compared to smooth case. The performance parameters of solar radiation, updraft velocity, temperature distribution, static pressure, power, and Nusselt number were varied. The effects of number, position, height, and width of the grooves on the performance were investigated. The results of this investigation show that the updraft velocity with the triangular groove increases by 1.5 times compared to the smooth case at solar radiation of 1000 W/m(2). At solar radiation of 1000 W/m(2), the power increases by 169%, 96%, and 19% for triangular, curved, and square grooves, respectively, compared to the smooth case. Moreover, the Nusselt number values with triangular groove and curved groove enhance by 42% and 26%, respectively, compared to the smooth case. The power increases by 1.98% for three grooves instead of using one groove at higher solar radiation. Increasing the groove height by 1.7 times, the power increases by 1.03 times at higher solar radiation. The power enhancement shows less sensitivity to the change of groove width at higher solar radiation.
引用
收藏
页数:16
相关论文
共 26 条
[1]  
ANSYS Inc, 2010, ANSYS CFX THEOR DOC
[2]   Experimental and numerical study of the impact of the collector roof inclination on the performance of a solar chimney power plant [J].
Ayadi, Ahmed ;
Driss, Zied ;
Bouabidi, Abdallah ;
Abid, Mohamed Salah .
ENERGY AND BUILDINGS, 2017, 139 :263-276
[3]  
Chhabra R.P., 2018, CRC HDB THERMAL ENG, P522
[4]   CFD analysis for solar chimney power plants [J].
Fasel, Hermann F. ;
Meng, Long ;
Shams, Ehsan ;
Gross, Andreas .
SOLAR ENERGY, 2013, 98 :12-22
[5]   Technical feasibility assessment of a solar chimney for food drying [J].
Ferreira, Andre G. ;
Maia, Cristlana B. ;
Cortez, Marcio F. B. ;
Valle, Ramon M. .
SOLAR ENERGY, 2008, 82 (03) :198-205
[6]   CFD (computational fluid dynamics) analysis of a solar-chimney power plant with inclined collector roof [J].
Gholamalizadeh, Ehsan ;
Kim, Man-Hoe .
ENERGY, 2016, 107 :661-667
[7]   Electricity production with low grade heat in thermal power plants by design improvement of a hybrid dry cooling tower and a solar chimney concept [J].
Ghorbani, Babak ;
Ghashami, Mohammad ;
Ashjaee, Mehdi .
ENERGY CONVERSION AND MANAGEMENT, 2015, 94 :1-11
[8]  
Guo P, 2016, APPL THERM ENG, V26, P107
[9]   Numerical simulations of solar chimney power plant with radiation model [J].
Guo, Peng-hua ;
Li, Jing-yin ;
Wang, Yuan .
RENEWABLE ENERGY, 2014, 62 :24-30
[10]  
Haaf W., 1983, International Journal of Solar Energy, V2, P3, DOI 10.1080/01425918308909911