Colon capsule endoscopy in colorectal cancer screening: a systematic review

被引:67
作者
Vuik, Fanny E. R. [1 ]
Nieuwenburg, Stella A., V [1 ]
Moen, Sarah [1 ]
Spada, Cristiano [2 ,3 ]
Senore, Carlo [4 ]
Hassan, Cesare [5 ]
Pennazio, Marco [6 ]
Rondonotti, Emanuele [7 ]
Pecere, Silvia [8 ]
Kuipers, Ernst J. [1 ]
Spaander, Manon C. W. [1 ]
机构
[1] Erasmus MC Univ Med Ctr, Dept Gastroenterol & Hepatol, Rotterdam, Netherlands
[2] Poliambulanza Fdn, Digest Endoscopy & Gastroenterol Unit, Brescia, Italy
[3] Catholic Univ, Fdn Policlin Univ Agostino Gemelli IRCCS, Digest Endoscopy Unit, Rome, Italy
[4] Univ Hosp Citta Salute & Sci, Epidemiol & Screening Unit CPO, Turin, Italy
[5] Nuovo Regina Margherita Hosp, Digest Endoscopy Unit, Rome, Italy
[6] Citta Salute & Sci Univ Hosp, Univ Gastroenterol Unit, Turin, Italy
[7] Osped Valduce, Gastroenterol Unit, Como, Italy
[8] Fdn Policlin Univ A Gemelli IRCCS, Digest Endoscopy Unit, Rome, Italy
关键词
COMPUTED TOMOGRAPHIC COLONOGRAPHY; EUROPEAN-SOCIETY; COLONOSCOPY; ACCURACY; POLYPS; INDIVIDUALS; MULTICENTER; QUALITY;
D O I
10.1055/a-1308-1297
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Introduction Primary colonoscopy and fecal immunochemical test (FIT) are the most commonly used colorectal cancer (CRC) screening modalities. Colon capsule endoscopy (CCE) might be an alternative. Data on the performance of CCE as a CRC screening tool in a screening population remain scarce. This is the first systematic review to provide an overview of the applicability of CCE as a CRC screening tool. Methods A systematic search was conducted of literature published up to September 2020.Studies reporting on CRC screening by second-generation CCE in an average-risk screening population were included. Results 582 studies were identified and 13 were included, comprising 2485 patients. Eight studies used CCE as a filter test after a positive FIT result and five studies used CCE for primary screening. The polyp detection rate of CCE was 24%-74%. For polyps >6mm, sensitivity of CCE was 79%-96% and specificity was 66%-97%. For polyps >= 10mm, sensitivity of CCE was 84%-97%, which was superior to computed tomographic colonography (CTC). The CRC detection rate for completed CCEs was 93% (25/27). Bowel preparation was adequate in 70%-92% of examinations, and completion rates varied from 57% to 92%, depending on the booster used. No CCE-related complications were described. Conclusion CCE appeared to be a safe and effective tool for the detection of CRC and polyps in a screening setting. Accuracy was comparable to colonoscopy and superior to CTC, making CCE a good alternative to colonoscopy in CRC screening programs, although completion rates require improvement.
引用
收藏
页码:815 / 824
页数:10
相关论文
共 27 条
[1]   Uptake of Colon Capsule Endoscopy vs Colonoscopy for Screening Relatives of Patients With Colorectal Cancer [J].
Adrian-de-Ganzo, Zaida ;
Alarcon-Fernandez, Onofre ;
Ramos, Laura ;
Gimeno-Garcia, Antonio ;
Alonso-Abreu, Inmaculada ;
Carrillo, Marta ;
Quintero, Enrique .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2015, 13 (13) :2293-+
[2]  
[Anonymous], EXP IND PILLCAM COL
[3]   A MULTICENTER, PROSPECTIVE, RANDOMIZED STUDY COMPARING THE DIAGNOSTIC YIELD OF COLON CAPSULE ENDOSCOPY VERSUS COMPUTED TOMOGRAPHIC COLONOGRAPHY IN A SCREENING POPULATION. RESULTS OF THE TOPAZ STUDY [J].
Cash, Brooks D. ;
Fleisher, Mark R. ;
Fern, Steven ;
Rajan, Elizabeth ;
Haithcock, Robyn ;
Kastenberg, David M. ;
Pound, David ;
Papageorgiou, Neofytos ;
Fernandez-Urien, Ignacio ;
Hyman, Alain ;
Maklansky, Joseph ;
Rex, Doug .
GASTROINTESTINAL ENDOSCOPY, 2019, 89 (06) :AB87-AB88
[4]   Colon capsule endoscopy versus CT colonography in FIT-positive colorectal cancer screening subjects: a prospective randomised trial-the VICOCA study [J].
Gonzalez-Suarez, Begona ;
Pages, Mario ;
Araujo, Isis Karina ;
Romero, Cristina ;
Rodriguez de Miguel, Cristina ;
Ayuso, Juan Ramon ;
Pozo, Angels ;
Vila-Casadesus, Maria ;
Serradesanferm, Anna ;
Gines, Angels ;
Fernandez-Esparrach, Gloria ;
Pellise, Maria ;
Lopez-Ceron, Maria ;
Flores, David ;
Cordova, Henry ;
Sendino, Oriol ;
Grau, Jaume ;
Llach, Josep ;
Serra-Burriel, Miquel ;
Cardenas, Andres ;
Balaguer, Francesc ;
Castells, Antoni .
BMC MEDICINE, 2020, 18 (01)
[5]   Capsule colonoscopy increases uptake of colorectal cancer screening [J].
Groth, Stefan ;
Krause, Horst ;
Behrendt, Rainer ;
Hill, Helge ;
Boerner, Michael ;
Bastuerk, Murat ;
Plathner, Nora ;
Schuette, Friedrich ;
Gauger, Ulrich ;
Riemann, Juergen Ferdinand ;
Altenhofen, Lutz ;
Roesch, Thomas .
BMC GASTROENTEROLOGY, 2012, 12
[6]   Colon capsule endoscopy as possible filter test for colonoscopy selection in a screening population with positive fecal immunology [J].
Holleran, Grainne ;
Leen, Ronan ;
O'Morain, Colm ;
McNamara, Deirdre .
ENDOSCOPY, 2014, 46 (06) :473-478
[7]   Back-to-back colon capsule endoscopy and optical colonoscopy in colorectal cancer screening individuals [J].
Kobaek-Larsen, M. ;
Kroijer, R. ;
Dyrvig, A. -K. ;
Buijs, M. M. ;
Steele, R. J. C. ;
Qvist, N. ;
Baatrup, G. .
COLORECTAL DISEASE, 2018, 20 (06) :479-485
[8]   A grading scale to evaluate colon cleansing for the PillCam COLON capsule: a reliability study [J].
Leighton, J. A. ;
Rex, D. K. .
ENDOSCOPY, 2011, 43 (02) :123-127
[9]   Learning Curve of Capsule Endoscopy [J].
Lim, Yun Jeong ;
Joo, Young Sung ;
Jung, Dae Young ;
Ye, Byong Duk ;
Kim, Ji Hyun ;
Cheon, Jae Hee ;
Kim, Seong Eun ;
Do, Jae Hyuk ;
Jang, Byung Ik ;
Moon, Jeong Seop ;
Kim, Jin Oh ;
Chun, Hoon Jae ;
Choi, Myung-Gyu .
CLINICAL ENDOSCOPY, 2013, 46 (06) :633-636
[10]   Applications of Colon Capsule Endoscopy [J].
Pasha S.F. .
Current Gastroenterology Reports, 2018, 20 (5)