Solid phase microextraction with matrix assisted laser desorption/ionization introduction to mass spectrometry and ion mobility spectrometry

被引:36
作者
Tong, H
Sze, N
Thomson, B
Nacson, S
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] MDS SCIEX, Concord, ON L4K 4V8, Canada
[3] Barringer, Mississauga, ON L4W 1V1, Canada
关键词
D O I
10.1039/b204701b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid phase microextraction (SPME) with matrix assisted laser desorption/ionization (MALDI) introduction was coupled to mass spectrometry and ion mobility spectrometry. Nicotine and myoglobin in matrix 2,5-dihydroxybenzonic acid (DHB), enkephalin and substance P in alpha-cyano-4-hydroxy cinnaminic acid were investigated as the target compounds. The tip of an optical fiber was silanized for extraction of the analytes of interest from solution. The optical fiber thus served as the sample extraction surface, the support for the sample plus matrix, and the optical pipe to transfer the laser energy from the laser to the sample. The MALDI worked under atmospheric pressure, and both an ion mobility spectrometer and a quadrupole/time-of-flight mass spectrometer were used for the detection of the SPME/MALDI signal. The spectra obtained demonstrate the feasibility of the SPME with MALDI introduction to mass spectrometry instrumentation.
引用
收藏
页码:1207 / 1210
页数:4
相关论文
共 20 条
  • [1] SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS
    ARTHUR, CL
    PAWLISZYN, J
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (19) : 2145 - 2148
  • [2] CISPER ME, 1994, ANAL CHEM, V66, P1879
  • [3] EICEMAN GA, 1989, ION MOBILITY SPECTRO, P197
  • [4] Coupling high-pressure MALDI with ion mobility/orthogonal time-of flight mass spectrometry
    Gillig, KJ
    Ruotolo, B
    Stone, EG
    Russell, DH
    Fuhrer, K
    Gonin, M
    Schultz, AJ
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (17) : 3965 - 3971
  • [5] Combined ion mobility time-of-flight mass spectrometry study of electrospray-generated ions
    Guevremont, R
    Siu, KWM
    Wang, JY
    Ding, LY
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (19) : 3959 - 3965
  • [6] Mass spectrometry for genotyping: an emerging tool for molecular medicine
    Jackson, PE
    Scholl, PF
    Groopman, JD
    [J]. MOLECULAR MEDICINE TODAY, 2000, 6 (07): : 271 - 276
  • [7] Atmospheric pressure matrix assisted laser desorption/ionization mass spectrometry
    Laiko, VV
    Baldwin, MA
    Burlingame, AL
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (04) : 652 - 657
  • [8] Injected-ion mobility analysis of biomolecules
    Liu, YS
    Valentine, SJ
    Counterman, AE
    Hoaglund, CS
    Clemmer, DE
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (23) : A728 - A735
  • [9] Loboda AV, 2000, RAPID COMMUN MASS SP, V14, P1047, DOI 10.1002/1097-0231(20000630)14:12<1047::AID-RCM990>3.0.CO
  • [10] 2-E