Influence of Platform Switching on Periimplant Bone Loss: A Systematic Review and Meta-analysis

被引:34
作者
Herekar, Manisha [1 ]
Sethi, Megha [1 ]
Mulani, Shahnawaz [1 ]
Fernandes, Aquaviva [2 ]
Kulkarni, Harish [3 ]
机构
[1] Maratha Mandals NGH Inst Dent Sci & Res Ctr, Dept Prosthodont, Belgaum 590010, Karnataka, India
[2] Goa Dent Coll & Hosp, Dept Prosthodont, Panaji, Goa, India
[3] Tatyasaheb Kore Dent Coll & Res Ctr, Dept Oral & Maxillofacial Surg, Warnanagar, India
关键词
platform switching; marginal bone loss; systematic review; meta-analysis; implants; implant-abutment junction; OSSEOINTEGRATED TITANIUM FIXTURES; RANDOMIZED CONTROLLED-TRIAL; MARGINAL TISSUE-REACTIONS; PERI-IMPLANT SOFT; DENTAL IMPLANTS; RADIOGRAPHIC EVALUATION; HISTOMETRIC EVALUATION; SUBMERGED IMPLANTS; BIOMECHANICAL ASPECTS; STRESS-DISTRIBUTION;
D O I
10.1097/ID.0000000000000080
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This meta-analysis aims to systematically review and draw a comparison between conventional implant designs and "platform-switched" implants in terms of crestal bone loss. Materials and Methods: Electronic (PubMed) and hand searches were conducted. Literature, clinical studies, and case reports pertaining to reduction of crestal bone loss and obtaining better esthetic outcome by platform switching were reviewed till October 2011. Controlled trials comparing marginal bone-level changes around platform-switched and platform-matched implants were selected. For the assessment of accuracy, meta-analysis was performed. Results: The marginal bone loss around platform-switched implants was significantly lesser than platform-matched implants (mean difference [MD]: -0.34; 95% confidence interval [CI]: -0.37 to -0.30; P < 0.00001). Conclusions: According to this review and meta-analysis, platform switching seems to preserve periimplant bone and soft tissue levels. However, long-term clinical studies on the proper diameter of abutment without deformation and the effective degree of platform switching in terms of the bone resorption are still awaited.
引用
收藏
页码:439 / 450
页数:12
相关论文
共 109 条
[11]  
Bidez M W, 1992, J Oral Implantol, V18, P264
[12]   Influence of Platform-Switching on Marginal Bone Levels for Implants With Mandibular Overdentures: A Retrospective Clinical Study [J].
Bilhan, Hakan ;
Mumcu, Emre ;
Erol, Sevin ;
Kutay, Oemer .
IMPLANT DENTISTRY, 2010, 19 (03) :250-258
[13]  
Black N, 1996, BRIT MED J, V312, P1215
[14]   Peri-implant inflammation defined by the implant-abutment interface [J].
Broggini, N ;
McManus, LM ;
Hermann, JS ;
Medina, R ;
Schenk, RK ;
Buser, D ;
Cochran, DL .
JOURNAL OF DENTAL RESEARCH, 2006, 85 (05) :473-478
[15]   Persistent acute inflammation at the implant-abutment interface [J].
Broggini, N ;
McManus, LM ;
Hermann, JS ;
Medina, RU ;
Oates, TW ;
Schenk, RK ;
Buser, D ;
Mellonig, JT ;
Cochran, DL .
JOURNAL OF DENTAL RESEARCH, 2003, 82 (03) :232-237
[16]   Crestal bone loss proximal to oral implants in older and younger adults [J].
Bryant, SR ;
Zarb, GA .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (06) :589-597
[17]  
Callan D P, 1998, Implant Dent, V7, P258, DOI 10.1097/00008505-199807040-00003
[18]   Immediate Provisionalization on a New Implant Design for Esthetic Restoration and Preserving Crestal Bone [J].
Calvo Guirado, Jose Luis ;
Saez Yuguero, Maria Rosario ;
Pardo Zamora, Guillermo ;
Munoz Barrio, Emilio .
IMPLANT DENTISTRY, 2007, 16 (02) :155-164
[19]   Biomechanical Aspects of Bone-Level Diameter Shifting at Implant-Abutment Interface [J].
Canay, Senay ;
Akca, Kivanc .
IMPLANT DENTISTRY, 2009, 18 (03) :239-244
[20]  
Canullo L, 2007, INT J ORAL MAX IMPL, V22, P995