Boron doped diamond sensor for sensitive determination of metronidazole: Mechanistic and analytical study by cyclic voltammetry and square wave voltammetry

被引:61
作者
Ammar, Hafedh Belhadj [1 ]
Ben Brahim, Mabrouk [1 ]
Abdelhedi, Ridha [1 ]
Samet, Youssef [1 ]
机构
[1] Univ Sfax, Dept Mat Engn, Elect & Environm Lab, Natl Engn Sch Sfax, Sfax 3038, Tunisia
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2016年 / 59卷
关键词
Boron doped diamond; Metronidazole; Square wave voltammetry; Analytical; GLASSY-CARBON ELECTRODE; PERFORMANCE LIQUID-CHROMATOGRAPHY; PASTE ELECTRODE; ELECTROCHEMICAL REDUCTION; SPECTROPHOTOMETRIC DETERMINATION; GAS-CHROMATOGRAPHY; FILM; BEHAVIOR; VALIDATION; POULTRY;
D O I
10.1016/j.msec.2015.10.025
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The performance of boron-doped diamond (BOO) electrode for the detection of metronidazole (MTZ) as the most important drug of the group of 5-nitroimidazole was proven using cyclic voltammetry (CV) and square wave voltammetry (SWV) techniques. A comparison study between BDD, glassy carbon and silver electrodes on the electrochemical response was carried out The process is pH-dependent. In neutral and alkaline media, one irreversible reduction peak related to the hydroxylamine derivative formation was registered, involving a total of four electrons. In acidic medium, a prepeak appears probably related to the adsorption affinity of hydroxylamine at the electrode surface. The BDD electrode showed higher sensitivity and reproducibility analytical response, compared with the other electrodes. The higher reduction peak current was registered at pH 11. Under optimal conditions, a linear analytical curve was obtained for the MTZ concentration in the range of 0.2-42 mu mol L-1, with a detection limit of 0.065 mu mol L-1. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:604 / 610
页数:7
相关论文
共 55 条
  • [1] A new approach to the spectrophotometric determination of metronidazole and tinidazole using p-dimethylaminobenzaldehyde
    Adegoke, Olajire Aremu
    Umoh, Offiong Edet
    [J]. ACTA PHARMACEUTICA, 2009, 59 (04) : 407 - 419
  • [2] [Anonymous], 1993, Statistics for Analytical Chemistry
  • [3] Square-wave voltammetric determination of bezafibrate in pharmaceutical formulations using a cathodically pretreated boron-doped diamond electrode
    Ardila, Jorge Armando
    Sartori, Elen Romao
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    [J]. TALANTA, 2013, 103 : 201 - 206
  • [4] Bard A.J., 1983, ELECTROCHIMIE PRINCI, P590
  • [5] Bard A.J., 2001, Electrochemical Methods: Fundamentals and Applications, V2nd, P97, DOI DOI 10.1108/ACMM.2003.12850EAE.001
  • [6] BARD AJ, 1980, ELECTROCHEMICAL METH, P223
  • [7] Voltammetry and determination of metronidazole at a carbon fiber microdisk electrode
    Bartlett, PN
    Ghoneim, E
    El-Hefnawy, G
    El-Hallag, I
    [J]. TALANTA, 2005, 66 (04) : 869 - 874
  • [8] Biçer E, 2009, CROAT CHEM ACTA, V82, P573
  • [9] Electrochemical reduction of metronidazole at a DNA-modified glassy carbon electrode
    Brett, AMO
    Serrano, SHP
    Gutz, I
    LaScalea, MA
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1997, 42 (02): : 175 - 178
  • [10] A core-shell molecularly imprinted polymer grafted onto a magnetic glassy carbon electrode as a selective sensor for the determination of metronidazole
    Chen, Dan
    Deng, Jian
    Liang, Jun
    Xie, Jie
    Hu, Canhui
    Huang, Kaihui
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 183 : 594 - 600