Stent and artery geometry determine intimal thickening independent of arterial injury

被引:178
作者
Garasic, JM
Edelman, ER
Squire, JC
Seifert, P
Williams, MS
Rogers, C
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Med,Cardiac Catheterizat Lab, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Brigham & Womens Hosp, Coronary Care Unit, Boston, MA 02115 USA
[3] Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02139 USA
[4] Medtron Arterial Vasc Engn, Santa Rosa, CA USA
关键词
stents; restenosis; angioplasty; pathology;
D O I
10.1161/01.CIR.101.7.812
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Clinical trials show that larger immediate postdeployment stent diameters provide greater ultimate luminal size, whereas animal data show that arterial injury and stent design determine late neointimal thickening. At deployment, a stent stretches a vessel, imposing a cross-sectional polygonal luminal shape that depends on the stent design, with each strut serving as a vertex. We asked whether this design-dependent postdeployment luminal geometry affects late neointimal thickening independently of the extent of strut-induced injury. Methods and Results-Stainless steel stents of 3 different configurations were implanted in rabbit iliac arteries for 3 or 28 days. Stents designed with 12 struts per cross section had 50% to 60% less mural thrombus and 2-fold less neointimal area than identical stents with only 8 struts per cross section. Sequential histological sectioning of individual stents showed that immediate postdeployment luminal geometry and subsequent neointimal area varied along the course of each stent subunit, Mathematical modeling of the shape imposed by the stent on the artery predicted late neointimal area, based on the re-creation of a circular vessel lumen within the confines of the initial stent-imposed polygonal luminal shape. Conclusions-Immediate postdeployment luminal geometry, dictated by stent design, determines neointimal thickness independently of arterial injury and may be useful for predicting patterns of intimal growth for novel stent designs.
引用
收藏
页码:812 / 818
页数:7
相关论文
共 25 条
  • [21] A randomized comparison of antiplatelet and anticoagulant therapy after the placement of coronary-artery stents
    Schomig, A
    Neumann, FJ
    Kastrati, A
    Schuhlen, H
    Blasini, R
    Hadamitzky, M
    Walter, H
    ZitzmannRoth, EM
    Richardt, G
    Alt, E
    Schmitt, C
    Ulm, K
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (17) : 1084 - 1089
  • [22] RESTENOSIS AND THE PROPORTIONAL NEOINTIMAL RESPONSE TO CORONARY-ARTERY INJURY - RESULTS IN A PORCINE MODEL
    SCHWARTZ, RS
    HUBER, KC
    MURPHY, JG
    EDWARDS, WD
    CAMRUD, AR
    VLIETSTRA, RE
    HOLMES, DR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) : 267 - 274
  • [23] THE RESTENOSIS PARADIGM REVISITED - AN ALTERNATIVE PROPOSAL FOR CELLULAR MECHANISMS
    SCHWARTZ, RS
    HOLMES, DR
    TOPOL, EJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (05) : 1284 - 1293
  • [24] A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE
    SERRUYS, PW
    DEJAEGERE, P
    KIEMENEIJ, F
    MACAYA, C
    RUTSCH, W
    HEYNDRICKX, G
    EMANUELSSON, H
    MARCO, J
    LEGRAND, V
    MATERNE, P
    BELARDI, J
    SIGWART, U
    COLOMBO, A
    GOY, JJ
    VANDENHEUVEL, P
    DELCAN, J
    MOREL, MA
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 489 - 495
  • [25] VanBelle E, 1997, CIRCULATION, V95, P438