Volume Measurement of Various Tissues Using the Image J Software

被引:48
作者
Rha, Eun Young [1 ]
Kim, Ji Min [1 ]
Yoo, Gyeol [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Dept Plast & Reconstruct Surg, Seoul 150713, South Korea
关键词
Breast; image J; orbit; volume measurement; BREAST VOLUME; RECONSTRUCTION;
D O I
10.1097/SCS.0000000000002022
中图分类号
R61 [外科手术学];
学科分类号
摘要
Various methods have been introduced to assess the tissue volume because volumetric evaluation is recognized as one of the most important steps in reconstructive surgery. Advanced volume measurement methods proposed recently use three-dimensional images. They are convenient but have drawbacks such as requiring expensive equipment and volume-analysis software. The authors devised a volume measurement method using the Image J software, which is in the public domain and does not require specific devices or software packages. The orbital and breast volumes were measured by our method using Image J data from facial computed tomography (CT) and breast magnetic resonance imaging (MRI). The authors obtained the final volume results, which were similar to the known volume values. The authors propose here a cost-effective, simple, and easily accessible volume measurement method using the Image J software.
引用
收藏
页码:E505 / E506
页数:2
相关论文
共 50 条
  • [31] Volume measurement of the pulverulent body carried by a conveyor belt using range sensors
    Yamane, K
    Tanaka, S
    SICE 2002: PROCEEDINGS OF THE 41ST SICE ANNUAL CONFERENCE, VOLS 1-5, 2002, : 2936 - 2938
  • [32] Application of open source software Image-J in microscopic movement tracking: movement track reconstruction and parameter algorithms
    Liu, Guangxu
    MECHANICAL, MATERIALS AND MANUFACTURING ENGINEERING, PTS 1-3, 2011, 66-68 : 827 - 832
  • [33] Counting pollen grains using readily available, free image processing and analysis software
    Costa, Clayton M.
    Yang, Suann
    ANNALS OF BOTANY, 2009, 104 (05) : 1005 - 1010
  • [34] Volume Measurement of Liver Metastases Using Multidetector Computed Tomography: Comparison of Lesion Diameter and Volume segmentation - A Phantom Study
    Rothe, J. H.
    Steffen, I. G.
    Lehmkuhl, L.
    Grieser, C.
    Mussler, A.
    Schnapauff, D.
    Stelter, L.
    Denecke, T.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (12): : 1082 - 1090
  • [35] Effect of visual cognition on the measurement of particle size using im-agej software
    Debut A.
    Vizuete K.
    Pazmiño K.
    Calderón J.
    Gallegos C.
    Gaona V.
    Current Materials Science, 2021, 14 (02): : 141 - 154
  • [36] A hemoglobin and volume measurement sensor for point of care testing analyzer using MEMS process
    Tanabe, Rikiya
    Hata, Seiichi
    Shimokohbe, Akira
    IEEJ Transactions on Sensors and Micromachines, 2007, 127 (05) : 267 - 271
  • [37] The Effect of Arm Position on Breast Volume Measurement Using Three-dimensional Imaging
    Wang, Chenglong
    Liu, Chunjun
    Cheng, Hao
    Chen, Lin
    Endo, Yori
    Luan, Jie
    AESTHETIC PLASTIC SURGERY, 2021, 45 (5) : 2009 - 2014
  • [38] The Effect of Arm Position on Breast Volume Measurement Using Three-dimensional Imaging
    Chenglong Wang
    Chunjun Liu
    Hao Cheng
    Lin Chen
    Yori Endo
    Jie Luan
    Aesthetic Plastic Surgery, 2021, 45 : 2009 - 2014
  • [39] Human Fatty Liver Volume Measurement Device Using Nano Graphene Polyvinyl Sensor
    Srilekha, M. K.
    Deepa, S. N.
    Shanker, N. R.
    Priya, M.
    IEEE SENSORS JOURNAL, 2023, 23 (20) : 25390 - 25400
  • [40] A volume measurement method for pneumatic pressure vessels using compressed-air discharge
    Peng, Jiehong
    Tadano, Kotaro
    Takeishi, Hisami
    Kagawa, Toshiharu
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (06)