Fault Prediction Based on Dynamic Model and Grey Time Series Model in Chemical Processes

被引:12
作者
Tian Wende [1 ]
Hu Minggang [2 ]
Li Chuankun [3 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Chem Engn, Qingdao 266042, Peoples R China
[2] Zibo Weichuang Petrochem Design Co Ltd, Zibo, Peoples R China
[3] SINOPEC, Qingdao Safety Engn Inst, State Key Lab Chem Safety, Qingdao 266071, Peoples R China
关键词
fault prediction; dynamic model; grey model; time series model; DIAGNOSIS; IDENTIFICATION; REGRESSION; SYSTEM;
D O I
10.1016/S1004-9541(14)60087-2
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper combines grey model with time series model and then dynamic model for rapid and in-depth fault prediction in chemical processes. Two combination methods are proposed. In one method, historical data is introduced into the grey time series model to predict future trend of measurement values in chemical process. These predicted measurements are then used in the dynamic model to retrieve the change of fault parameters by model based diagnosis algorithm. In another method, historical data is introduced directly into the dynamic model to retrieve historical fault parameters by model based diagnosis algorithm. These parameters are then predicted by the grey time series model. The two methods are applied to a gravity tank example. The case study demonstrates that the first method is more accurate for fault prediction.
引用
收藏
页码:643 / 650
页数:8
相关论文
共 25 条
[1]   Fault detection, identification and diagnosis using CUSUM based PCA [J].
Bin Shams, M. A. ;
Budman, H. M. ;
Duever, T. A. .
CHEMICAL ENGINEERING SCIENCE, 2011, 66 (20) :4488-4498
[2]  
Chiang L.H., 2003, FAULT DETECTION DIAG, P179
[3]   Model-based fault diagnosis in technical processes [J].
Frank, PM ;
Ding, SX ;
Marcu, T .
TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2000, 22 (01) :57-101
[4]   Signed Directed Graph and Qualitative Trend Analysis Based Fault Diagnosis in Chemical Industry [J].
Gao Dong ;
Wu Chongguang ;
Zhang Beike ;
Ma Xin .
CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2010, 18 (02) :265-276
[5]   Applications of improved grey prediction model for power demand forecasting [J].
Hsu, CC ;
Chen, CY .
ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (14) :2241-2249
[6]   Model-based fault-detection and diagnosis - status and applications [J].
Isermann, R .
ANNUAL REVIEWS IN CONTROL, 2005, 29 (01) :71-85
[7]   Optimal Bayesian fault prediction scheme for a partially observable system subject to random failure [J].
Kim, Michael Jong ;
Jiang, Rui ;
Makis, Viliam ;
Lee, Chi-Guhn .
EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2011, 214 (02) :331-339
[8]   Prediction of Pressure Drop of Slurry Flow in Pipeline by Hybrid Support Vector Regression and Genetic Algorithm Model [J].
Lahiri, S. K. ;
Ghanta, K. C. .
CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2008, 16 (06) :841-848
[9]   Fault isolation by partial dynamic principal component analysis in dynamic process [J].
Li Rongyu ;
Rong Gang .
CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2006, 14 (04) :486-493
[10]  
Liu Sifeng, 1997, Journal of Grey System, V9, P351