Organotin compounds: An ionophore system for fluoride ion recognition

被引:29
作者
Chandra, Sudeshna
Ruzicka, Ales
Svec, Petr
Lang, Heinrich
机构
[1] Tech Univ Chemnitz, Fak Naturwissensch, Inst Chem, Lehrstuhl Anorgan Chem, D-09111 Chemnitz, Germany
[2] Univ Pardubice, Fac Chem Technol, Dept Gen & Inorgan Chem, Pardubice 53210, Czech Republic
关键词
organotin compounds; fluoride selective electrode; ionophores; anion recognition;
D O I
10.1016/j.aca.2006.06.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion-selective properties were established for membrane electrodes prepared by using organotin compounds of type ((LRSnF2)-R-CN), (R=n-Bu (I),=Ph (II)) and ((LSnF3)-Sn-CN) (III) (L-CN=C6H4(CH2NMe2)-2). Electrodes formulated with the optimized membranes containing the organotin compounds I-III as ionophores and sodium tetraphenylborate (10-30%) exhibited high selectivity for fluoride over other anions. An electrode prepared with ionophore II using dibutyl phthalate as the plasticizer and 15% sodium tetraphenylborate (NaTPB) as anion additive, possesses the best potentiometric response characteristics. It shows a detection limit of 7.9 x 10(-7) M with a slope of 62.7 mV decade I of activity in buffer solutions of pH 5.5. The interference from other anions is suppressed under this optimized measurement conditions. An entirely non-Hofmeister selectivity sequence (F- > CH3COO- > Cl- > I- similar to Br > ClO4- > NO2- > NO3- > SCN-) with remarkable preference towards fluoride is obtained. The influence on the electrode performances by anion additive was studied, and the possible response mechanism was investigated by UV-vis spectra. The electrode has been used for direct determination of fluoride in drinking mineral water with satisfactory results. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 44 条
[1]   Cationic or anionic sites?: Selectivity optimization of ion-selective electrodes based on charged ionophores [J].
Amemiya, S ;
Bühlmann, P ;
Pretsch, E ;
Rusterholz, B ;
Umezawa, Y .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1618-1631
[2]   Neutral anion receptors: design and application [J].
Antonisse, MMG ;
Reinhoudt, DN .
CHEMICAL COMMUNICATIONS, 1998, (04) :443-448
[3]   Mercuracarborand "anti-crown ether"-based chloride sensitive liquid/polymeric membrane electrodes [J].
Badr, IHA ;
Diaz, M ;
Hawthorne, MF ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 1999, 71 (07) :1371-1377
[4]   ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY [J].
BAKKER, E ;
MALINOWSKA, E ;
SCHILLER, RD ;
MEYERHOFF, ME .
TALANTA, 1994, 41 (06) :881-890
[5]   Selectivity of liquid membrane ion-selective electrodes [J].
Bakker, E .
ELECTROANALYSIS, 1997, 9 (01) :7-12
[6]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[7]  
Beer PD, 2001, ANGEW CHEM INT EDIT, V40, P486, DOI 10.1002/1521-3773(20010202)40:3<486::AID-ANIE486>3.3.CO
[8]  
2-G
[9]   Tripodal ionophore with sulfate recognition properties for anion-selective electrodes [J].
Berrocal, MJ ;
Cruz, A ;
Badr, IHA ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5295-5299
[10]   BUFFER SYSTEMS FOR USE WITH THE FLUORIDE ELECTRODE IN FLOW-INJECTION ANALYSIS [J].
CARDWELL, TJ ;
CATTRALL, RW ;
HAUSER, PC ;
HAMILTON, IC .
ANALYTICAL CHEMISTRY, 1987, 59 (01) :206-208