Computer Simulation as an Aid in the Rating of a Transformer On-load Tap Changer

被引:5
|
作者
Pasquotto de Lima, Paulo Afonso [1 ]
Lopes Cabral, Sergio Henrique [2 ]
机构
[1] WEG Transmiss & Distribut, BR-89065000 Blumenau, SC, Brazil
[2] Fundacao Univ Reg Blumenau DEET, BR-89030000 Blumenau, SC, Brazil
关键词
on-load tap changer; power transformer; impulsive voltage; lightning surge; basic impulse insulation level;
D O I
10.1109/MEI.2014.6843766
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The on-load tap changer (OLTC) is a crucial and expensive component of every power transformer. Its primary function is the dynamic adjustment of load voltage to specified levels without interrupting load current. Apart from thermal limitations at each tap position, the main concern in correctly rating an OLTC is the basic impulse insulation level (BIL). The reason for this is that during the standard BIL test on a power transformer, damaging overvoltage may develop on the regulating winding, which is transferred to the OLTC, which may damage the OLTC, and as a result, fail the BIL test on the power transformer. In regard to the lightning impulse voltage test, since the overvoltage that develops is a consequence of the distributed capacitance and inductance of the regulating winding, and as there are several types of regulating windings, each with different values of distributed capacitance and inductance, the correct rating of the OLTC will depend on the type of regulating winding used. Therefore, the transformer designer must be able to estimate the transferred impulse overvoltage, for the purpose of not only choosing the right type of regulating winding, but also to limit the overvoltage through passive or active means, for example incorporating electrostatic shielding in the regulating winding or installing a MOV surge arrestor. With this aim, computational tools are a powerful aid for assisting the transformer designer, since they allow the computation of distributed capacitance and inductance of the regulating winding, as well as estimating the distributed impulsive voltage. On the other hand, in regard to voltage withstand at power frequency, the induced AC voltage test is also important for determining the BIL of an OLTC. This article presents a practical case as to the steps that must be taken by a transformer designer in rating a power transformer OLTC. © 2014 IEEE.
引用
收藏
页码:34 / 38
页数:5
相关论文
共 50 条
  • [41] 3-Dimensional Simulation of On-load Tap Changer Subjected to Short Circuit Current
    Li, Peng
    Sui, Huaze
    Wang, Ke
    Zhang, Shuqi
    Li, Gang
    Li, Geqi
    2021 5TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY ENGINEERING (ICPEE 2021), 2021, : 61 - 65
  • [42] Study on the condition of reverse control action of tap changer in a single on-load tap changer power system
    Yorino, Naoto, 1600, Scripta Technica Inc, New York, NY, United States (114):
  • [43] Application of the Acoustic Emission Method for Diagnosis of On-Load Tap Changer
    Majchrzak, Henryk
    Cichon, Andrzej
    Borucki, Sebastian
    ARCHIVES OF ACOUSTICS, 2017, 42 (01) : 29 - 35
  • [44] On-load Tap Changer Diagnosis: Interpretation of Dynamic Resistance Deviations
    Erbrink, J. J.
    Gulski, E.
    Smit, J. J.
    Leich, R.
    Seitz, P. P.
    Quak, B.
    CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,
  • [45] Intelligent Control of On-Load Tap Changing Transformer
    Bahadornejad, Momen
    Nair, Nirmal-Kumar C.
    IEEE TRANSACTIONS ON SMART GRID, 2014, 5 (05) : 2255 - 2263
  • [46] On-Load Tap-Changer Control by a Fuzzy Logic Controller
    Choukri, Tarbi
    Chekenbah, Hamid
    Lasri, Rafik
    Bouhorma, Mohammed
    Maataoui, Yassir
    PROCEEDINGS OF 2019 IEEE 4TH WORLD CONFERENCE ON COMPLEX SYSTEMS (WCCS' 19), 2019, : 79 - 84
  • [47] A Segmented Preprocessing Method for the Vibration Signal of an On-Load Tap Changer
    Shang, Rongyan
    Peng, Changqing
    Fang, Ruiming
    ELECTRONICS, 2021, 10 (02) : 1 - 12
  • [48] Reverse action of on-load tap changer in association with voltage collapse
    Ohtsuki, Hiroshi
    Yokoyama, Akihiko
    Sekine, Yasuji
    IEEE Transactions on Power Systems, 1991, 6 (02) : 300 - 306
  • [49] Power system voltage stability affected by on-load tap changer
    Peng, Zhiwei
    Hu, Guogen
    Han, Zhenxiang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 18 (06): : 408 - 412
  • [50] Improvement in the performance of on-load tap changer transformers operating in series
    Smith, CA
    Redfern, MA
    Potts, S
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1905 - 1910