Computer Simulation as an Aid in the Rating of a Transformer On-load Tap Changer

被引:5
|
作者
Pasquotto de Lima, Paulo Afonso [1 ]
Lopes Cabral, Sergio Henrique [2 ]
机构
[1] WEG Transmiss & Distribut, BR-89065000 Blumenau, SC, Brazil
[2] Fundacao Univ Reg Blumenau DEET, BR-89030000 Blumenau, SC, Brazil
关键词
on-load tap changer; power transformer; impulsive voltage; lightning surge; basic impulse insulation level;
D O I
10.1109/MEI.2014.6843766
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The on-load tap changer (OLTC) is a crucial and expensive component of every power transformer. Its primary function is the dynamic adjustment of load voltage to specified levels without interrupting load current. Apart from thermal limitations at each tap position, the main concern in correctly rating an OLTC is the basic impulse insulation level (BIL). The reason for this is that during the standard BIL test on a power transformer, damaging overvoltage may develop on the regulating winding, which is transferred to the OLTC, which may damage the OLTC, and as a result, fail the BIL test on the power transformer. In regard to the lightning impulse voltage test, since the overvoltage that develops is a consequence of the distributed capacitance and inductance of the regulating winding, and as there are several types of regulating windings, each with different values of distributed capacitance and inductance, the correct rating of the OLTC will depend on the type of regulating winding used. Therefore, the transformer designer must be able to estimate the transferred impulse overvoltage, for the purpose of not only choosing the right type of regulating winding, but also to limit the overvoltage through passive or active means, for example incorporating electrostatic shielding in the regulating winding or installing a MOV surge arrestor. With this aim, computational tools are a powerful aid for assisting the transformer designer, since they allow the computation of distributed capacitance and inductance of the regulating winding, as well as estimating the distributed impulsive voltage. On the other hand, in regard to voltage withstand at power frequency, the induced AC voltage test is also important for determining the BIL of an OLTC. This article presents a practical case as to the steps that must be taken by a transformer designer in rating a power transformer OLTC. © 2014 IEEE.
引用
收藏
页码:34 / 38
页数:5
相关论文
共 50 条
  • [31] Research on the Switching Arc Loss of on-Load Tap Changer
    Song, Dongdong
    Ma, Jiwei
    Ma, Yuquan
    Lin, Hongju
    Liu, Shengtao
    IEEE ACCESS, 2019, 7 : 180793 - 180803
  • [32] On-load tap changer diagnosis with dynamic resistance measurements
    Jongen, Rogier
    Seitz, Paul P.
    Strehl, Thomas
    Smit, Johan
    Leich, Rory
    Gulski, Edward
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 485 - 488
  • [33] Protection Considerations for an Improperly Installed On-Load Tap Changer
    Rangel, Alex
    2021 74TH CONFERENCE FOR PROTECTIVE RELAY ENGINEERS (CPRE), 2021,
  • [34] Efficient Switching Test Technique of On-load Tap Changer
    Wang K.
    Wang R.
    Li G.
    Wang Y.
    Zhang S.
    Li P.
    Li G.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (24): : 9752 - 9762
  • [35] Methods of diagnosis of for failures power On-load tap changer
    Rivas Trujillo, Edwin
    Carlos Burgos, Juan
    Garcia Prada, Juan Carlos
    INGENIERIA, 2007, 12 (02): : 68 - 72
  • [36] A new scheme for on-load tap-changer of transformers
    Gao, DW
    Lu, QC
    Luo, JH
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 1016 - 1020
  • [37] Coordination of Transformer On-Load Tap Changer and PV Smart Inverters for Voltage Control of Distribution Feeders
    Ku, Te-Tien
    Lin, Chia-Hung
    Chen, Chao-Shun
    Hsu, Cheng-Ting
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (01) : 256 - 264
  • [38] Fault Recognition of On-load Tap-changer in Power Transformer Based on Convolutional Neural Network
    Zeng Q.
    Wang F.
    Zheng Y.
    He W.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (11): : 144 - 151
  • [39] Coordination of Transformer On-Load Tap Changer and PV Smart Inverters for Voltage Control of Distribution Feeders
    Ku, T. T.
    Lin, C. H.
    Chen, C. S.
    Hsu, C. T.
    2018 IEEE/IAS 54TH INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE (I&CPS), 2018,
  • [40] PV Generation in Distribution Network and its Impact on Power Transformer On-load Tap Changer Operation
    Wanik, Mohd Zamri Che
    Bukshaisha, Mohammed M.
    Chaudhry, Salman R.
    2017 IEEE MANCHESTER POWERTECH, 2017,