Computer Simulation as an Aid in the Rating of a Transformer On-load Tap Changer

被引:5
|
作者
Pasquotto de Lima, Paulo Afonso [1 ]
Lopes Cabral, Sergio Henrique [2 ]
机构
[1] WEG Transmiss & Distribut, BR-89065000 Blumenau, SC, Brazil
[2] Fundacao Univ Reg Blumenau DEET, BR-89030000 Blumenau, SC, Brazil
关键词
on-load tap changer; power transformer; impulsive voltage; lightning surge; basic impulse insulation level;
D O I
10.1109/MEI.2014.6843766
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The on-load tap changer (OLTC) is a crucial and expensive component of every power transformer. Its primary function is the dynamic adjustment of load voltage to specified levels without interrupting load current. Apart from thermal limitations at each tap position, the main concern in correctly rating an OLTC is the basic impulse insulation level (BIL). The reason for this is that during the standard BIL test on a power transformer, damaging overvoltage may develop on the regulating winding, which is transferred to the OLTC, which may damage the OLTC, and as a result, fail the BIL test on the power transformer. In regard to the lightning impulse voltage test, since the overvoltage that develops is a consequence of the distributed capacitance and inductance of the regulating winding, and as there are several types of regulating windings, each with different values of distributed capacitance and inductance, the correct rating of the OLTC will depend on the type of regulating winding used. Therefore, the transformer designer must be able to estimate the transferred impulse overvoltage, for the purpose of not only choosing the right type of regulating winding, but also to limit the overvoltage through passive or active means, for example incorporating electrostatic shielding in the regulating winding or installing a MOV surge arrestor. With this aim, computational tools are a powerful aid for assisting the transformer designer, since they allow the computation of distributed capacitance and inductance of the regulating winding, as well as estimating the distributed impulsive voltage. On the other hand, in regard to voltage withstand at power frequency, the induced AC voltage test is also important for determining the BIL of an OLTC. This article presents a practical case as to the steps that must be taken by a transformer designer in rating a power transformer OLTC. © 2014 IEEE.
引用
收藏
页码:34 / 38
页数:5
相关论文
共 50 条
  • [1] Mechanical Fault Diagnosis of On-load Tap Changer of Power Transformer by Clustering Algorithm
    Chen, Peilong
    Ma, Xiaohong
    Wang, Fenghua
    Xie, Fangxin
    Zhou, Dongxu
    2018 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2018,
  • [2] Power Transformer Transient Modeling Considering the Effects of On-Load Tap Changer
    Ahmad, Asad
    Fang, Wanliang
    Liu, Jun
    Hao, Xudong
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 766 - 770
  • [3] Analysis of Time Domain Characteristic of Transformer On-load Tap-changer
    Yu Bing
    Zhao Lin
    Lin Haofan
    Yang Yong
    2021 THE 6TH INTERNATIONAL CONFERENCE ON INTEGRATED CIRCUITS AND MICROSYSTEMS (ICICM 2021), 2021, : 390 - 393
  • [4] AC Test Method for the Dynamic Characteristics of Transformer on-Load Tap Changer
    Zhou, Hongwei
    Dong, Tian
    Liu, Fu
    INTERNATIONAL CONFERENCE ON ELECTRICAL AND CONTROL ENGINEERING (ICECE 2015), 2015, : 523 - 530
  • [5] Application vibroacoustic in the diagnosis of on-load tap changer
    Raclaw, Marcin
    Gielniak, Jaroslaw
    PRZEGLAD ELEKTROTECHNICZNY, 2018, 94 (10): : 126 - 129
  • [6] Dynamic Simulation and Optimization of Mechanical Switching Characteristics of On-load Tap Changer
    Zhang, Shuqi
    Zhang, Yao
    Wang, Ke
    Li, Jinzhong
    Li, Gang
    Yang, Fan
    Li, Geqi
    2021 5TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY ENGINEERING (ICPEE 2021), 2021, : 36 - 40
  • [7] Vibration Characteristic Comparison Between Vacuum Arcing On-load Tap-changer and Oil Blast On-load Tap-changer
    Wang F.
    Fan J.
    Zheng Y.
    He W.
    Qian Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (09): : 2834 - 2841
  • [8] Effect of Insulation Oil on Vibration Signals of On-load Tap-changer of Power Transformer
    Wang F.
    Xie F.
    Wang W.
    Zheng Y.
    He W.
    Qian Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (10): : 3273 - 3279
  • [9] Investigation of Causes of Dry-Type Transformer On-Load Tap-Changer Insulation
    Brilinskiy, Andrey S.
    Evdokunin, Georgy A.
    Chudny, Vladimir S.
    Mingazov, Radmir I.
    Ponomarev, Timofey A.
    PROCEEDINGS OF THE 2018 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (EICONRUS), 2018, : 591 - 597
  • [10] Analysis of Vibration Signal for Power Transformer On-Load Tap Changer (OLTC) Condition Monitoring
    Seo, Junhyuck
    Ma, Hui
    Saha, Tapan K.
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,