Research and Design of Methane Gas Inspection Tour System Based on Low-Power SCM MSP430F149

被引:0
作者
Chen, Yu [1 ]
机构
[1] Zhengzhou Inst Aeronaut Ind Management, Zhengzhou 450015, Peoples R China
来源
2008 INTERNATIONAL SYMPOSIUM ON INTELLIGENT INFORMATION TECHNOLOGY APPLICATION, VOL II, PROCEEDINGS | 2008年
关键词
D O I
10.1109/IITA.2008.48
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper designs a hype of methane gas inspection tour and control system based on single chip microprocessor (SCM) technology and wireless communication technology, etc. This system fulfills methane gas concentration collection by LXY-3 methane gas sensor. SCM MSP430F149 analyzes and processes data as central core controller. Wireless transceiver nRF401 realizes data communication between field monitor and inspection tour equipment. And main controller is connected with inspection four equipment by MAX232 interface. This paper describes system structure, parts of hardware and software design in detail. Experiments show that system monitor error is less than +/- 0.3% to methane gas concentration between 0 and 5%, which performs well to coal mine methane gas concentration monitor and alarm design demand as expected.
引用
收藏
页码:503 / 507
页数:5
相关论文
共 8 条
  • [1] CHEN SH, 2006, MECH ELECT, P12
  • [2] DING D, 2008, IND MINE AUTOMATION, P64
  • [3] JIA ZG, 2000, INT ELECT ELEMENTS, P20
  • [4] LI JF, 2006, MICROCOMPUTER INFORM, V22, P241
  • [5] LUO XZ, 2007, MECH MANAGEMENT DEV, P92
  • [6] QIAN JX, 2005, MODERN ELECT POWER, P72
  • [7] WANG RL, 1998, SENSOR TECHNOLOGY CO
  • [8] ZHOU QD, 2003, INT ELECT ELEMENTS, P55