A preliminary study of the role of modulated electron beams in intensity modulated radiotherapy, using automated beam orientation and modality selection

被引:14
作者
Das, SK
Bell, M
Marks, LB
Rosenman, JG
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
[2] Univ N Carolina, Dept Radiat Oncol, Chapel Hill, NC USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2004年 / 59卷 / 02期
关键词
electrons; modulation; optimization; orientation;
D O I
10.1016/j.ijrobp.2004.01.049
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop an algorithm for optimal beam arrangement selection in intensity-modulated radiotherapy (IMRT) of mixed photon and electron beams. To apply this algorithm to study the utility of modulated electron beams in the context of IMRT planning. Methods and Materials: The optimization algorithm selects, for a user-specified number of beams, the optimal IMRT arrangement (beam orientations, and photon/electron modality for each orientation) using a novel fast heuristic intensity modulation procedure. The algorithm was employed to select optimal beam arrangements for breast (two, four, and six axial beams) and head-and-neck (three, four, five, and seven nonaxial beams) cases. Results: For the two cases, increasing the number of selected beams: (1) increased the number of electron beams for the breast case, but not more than one electron beam was selected for the head-and-neck case; (2) decreased critical structure doses for both cases; and (3) decreased target homogeneity for the breast case, but improved it for the head-and-neck case. Conclusions: In the two cases analyzed using the selection algorithm, the primary role of modulated electrons differs based on treatment site-normal tissue dose reduction in breast and target homogeneity improvement in head and neck. Although this preliminary study with two cases appears to suggest that the role of intensity-modulated electrons differs based on treatment site, further investigation of large numbers of cases and varied treatment sites are required to establish a definitive conclusion. (C) 2004 Elsevier Inc.
引用
收藏
页码:602 / 617
页数:16
相关论文
共 51 条
  • [31] Cardiac avoidance in breast radiotherapy: a comparison of simple shielding techniques with intensity-modulated radiotherapy
    Landau, D
    Adams, EJ
    Webb, S
    Ross, G
    [J]. RADIOTHERAPY AND ONCOLOGY, 2001, 60 (03) : 247 - 255
  • [32] Monte Carlo and experimental investigations of multileaf collimated electron beams for modulated electron radiation therapy
    Lee, MC
    Jiang, SB
    Ma, CM
    [J]. MEDICAL PHYSICS, 2000, 27 (12) : 2708 - 2718
  • [33] Matching photon and electron fields with dynamic intensity modulation
    Li, JG
    Xing, L
    Boyer, AL
    Hamilton, RJ
    Spelbring, DR
    Turian, JV
    [J]. MEDICAL PHYSICS, 1999, 26 (11) : 2379 - 2384
  • [34] Breast-conserving radiation therapy using combined electron and intensity-modulated radiotherapy technique
    Li, JG
    Williams, SS
    Goffinet, DR
    Boyer, AL
    Xing, L
    [J]. RADIOTHERAPY AND ONCOLOGY, 2000, 56 (01) : 65 - 71
  • [35] Electron wedges for radiation therapy
    Lief, EP
    Lo, YC
    Humm, JL
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (01): : 233 - 243
  • [36] Intensity modulation for breast treatment using static multi-leaf collimators
    Lo, YC
    Yasuda, G
    Fitzgerald, TJ
    Urie, MM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (01): : 187 - 194
  • [37] Beyond bixels: Generalizing the optimization parameters for intensity modulated radiation therapy
    Markman, J
    Low, DA
    Beavis, AW
    Deasy, JO
    [J]. MEDICAL PHYSICS, 2002, 29 (10) : 2298 - 2304
  • [38] Inverse treatment planning and stereotactic intensity-modulated radiation therapy (IMRT) of the tumor and lymph node levels for nasopharyngeal carcinomas
    Münter, MW
    Debus, J
    Hof, H
    Nill, S
    Häring, P
    Bortfeld, T
    Wannenmacher, M
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 (09) : 517 - 523
  • [39] Reporting and analyzing dose distributions: A concept of equivalent uniform dose
    Niemierko, A
    [J]. MEDICAL PHYSICS, 1997, 24 (01) : 103 - 110
  • [40] Optimisation of radiotherapy for carcinoma of the parotid gland: a comparison of conventional, three-dimensional conformal, and intensity-modulated techniques
    Nutting, CM
    Rowbottom, CG
    Cosgrove, VP
    Henk, JM
    Dearnaley, DP
    Robinson, MH
    Conway, J
    Webb, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2001, 60 (02) : 163 - 172