Three-dimensional bone response to commercially pure titanium, hydroxyapatite, and calcium-ion-mixing titanium in rabbits

被引:0
作者
Ichikawa, T
Hanawa, T
Ukai, H
Murakami, K
机构
[1] Univ Tokushima, Sch Dent, Dept Removable Prosthodont, Tokushima 770, Japan
[2] Natl Res Inst Met, Tsukuba, Ibaraki 305, Japan
[3] Ishikawajima Harima Heavy Ind Co Ltd, Res Inst, Tokyo 135, Japan
关键词
calcium-ion-mixing titanium; hydroxyapatite; percent bone volume; 3-dimensional bone response; titanium;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Three-dimensional bone response to 3 biomaterials-commercially pure titanium (Ti), hydroxyapatite (HA) and calcium-ion-mixing titanium (Ca-Ti)-embedded in the tibiae of rabbits was examined chronologically. The rabbits were sacrificed at 2, 4 and 8 weeks after implantation, and the percent bone volume around each implant was calculated from the implant surface to each of 4 measurements: 36 mu m, 0.25 mm, 0.5 mm, and 1.0 mm in 2 regions (cortical bone and bone marrow regions). Percent bone volume in the cortical bone was consistent, whereas in the bone marrow region, the percent bone volume varied according to implant material, implantation period, and distance from the implant surface. With Ti implants the percent increased gradually up to 8 weeks at each distance, whereas in HA and Ca-Ti implants the percent was largest at 4 weeks and increased closer to the surface. The percent with Ti implants was largest at 36 mu m to 0.25 mm. Aspect of bone response to Ca-Ti was its position intermediate between those of HA and Ti. The decrease of the percent at 8 weeks was smaller than HA.
引用
收藏
页码:231 / 238
页数:8
相关论文
共 34 条
  • [1] Hydroxyapatite-coated implants: A case against their use
    Albrektsson, T
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1998, 56 (11) : 1312 - 1326
  • [2] STATE-OF-THE-ART IN ORAL IMPLANTS
    ALBREKTSSON, T
    SENNERBY, L
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1991, 18 (06) : 474 - 481
  • [3] Albrektsson T O, 1994, Periodontol 2000, V4, P58, DOI 10.1111/j.1600-0757.1994.tb00006.x
  • [4] Biesbrock A R, 1995, Int J Oral Maxillofac Implants, V10, P712
  • [5] BRANEMARK PI, 1985, TISSUE INTEGRATED PR, P241
  • [6] BRUNSKI JB, 1991, BONE-BIOMATERIAL INTERFACE, P391
  • [7] INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS
    BUSER, D
    SCHENK, RK
    STEINEMANN, S
    FIORELLINI, JP
    FOX, CH
    STICH, H
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07): : 889 - 902
  • [8] COOK DI, 1987, HDB PHYSL GASTROINTE, V2, P1
  • [9] HYDROXYLAPATITE COATING OF POROUS IMPLANTS IMPROVES BONE INGROWTH AND INTERFACE ATTACHMENT STRENGTH
    COOK, SD
    THOMAS, KA
    DALTON, JE
    VOLKMAN, TK
    WHITECLOUD, TS
    KAY, JF
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (08): : 989 - 1001
  • [10] De Groot K., 1981, BIOCOMPATIBILITY CLI, P199