Multispectral Video Fusion for Non-Contact Monitoring of Respiratory Rate and Apnea

被引:61
作者
Scebba, Gaetano [1 ]
Poian, Giulia [1 ]
Karlen, Walter [1 ]
机构
[1] Swiss Fed Inst Technol, Dept Hlth Sci & Technol, Mobile Hlth Syst Lab, Inst Robot & Intelligent Syst, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
Cameras; Finite impulse response filters; Monitoring; Estimation; Modulation; Lung; Electrocardiography; Respiratory rate; apnea; non-contact physiological monitoring; nearables; multispectral fusion; thermal imaging; MOTION; ECG;
D O I
10.1109/TBME.2020.2993649
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Continuous monitoring of respiratory activity is desirable in many clinical applications to detect respiratory events. Non-contact monitoring of respiration can be achieved with near- and far-infrared spectrum cameras. However, current technologies are not sufficiently robust to be used in clinical applications. For example, they fail to estimate an accurate respiratory rate (RR) during apnea. We present a novel algorithm based on multispectral data fusion that aims at estimating RR also during apnea. The algorithm independently addresses the RR estimation and apnea detection tasks. Respiratory information is extracted from multiple sources and fed into an RR estimator and an apnea detector whose results are fused into a final respiratory activity estimation. We evaluated the system retrospectively using data from 30 healthy adults who performed diverse controlled breathing tasks while lying supine in a dark room and reproduced central and obstructive apneic events. Combining multiple respiratory information from multispectral cameras improved the root mean square error (RMSE) accuracy of the RR estimation from up to 4.64 monospectral data down to 1.60 breaths/min. The median F1 scores for classifying obstructive (0.75 to 0.86) and central apnea (0.75 to 0.93) also improved. Furthermore, the independent consideration of apnea detection led to a more robust system (RMSE of 4.44 vs. 7.96 breaths/min). Our findings may represent a step towards the use of cameras for vital sign monitoring in medical applications.
引用
收藏
页码:350 / 359
页数:10
相关论文
共 58 条
  • [1] Neonatal non-contact respiratory monitoring based on real-time infrared thermography
    Abbas, Abbas K.
    Heimann, Konrad
    Jergus, Katrin
    Orlikowsky, Thorsten
    Leonhardt, Steffen
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2011, 10
  • [2] Automated Recognition of Obstructive Sleep Apnea Syndrome Using Support Vector Machine Classifier
    Al-Angari, Haitham M.
    Sahakian, Alan V.
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2012, 16 (03): : 463 - 468
  • [3] Spectral analysis of electroencephalogram and oximetric signals in obstructive sleep apnea diagnosis
    Alvarez, Daniel
    Hornero, Roberto
    Victor Marcos, J.
    del Campo, Felix
    Lopez, Miguel
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 400 - +
  • [4] [Anonymous], 2006, G KHAN N AVU O LU H
  • [5] Baharestani MM, 2007, OSTOMY WOUND MANAG, V53, P34
  • [6] Bartula M, 2013, IEEE ENG MED BIO, P2672, DOI 10.1109/EMBC.2013.6610090
  • [7] Berry R. B., 2013, American Academy of Sleep Medicine, V53, P1689
  • [8] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [9] Overview of Integrative Assessment of Marine Systems: The Ecosystem Approach in Practice
    Borja, Angel
    Elliott, Michael
    Andersen, Jesper H.
    Berg, Torsten
    Carstensen, Jacob
    Halpern, Benjamin S.
    Heiskanen, Anna-Stiina
    Korpinen, Samuli
    Lowndes, Julia S. Stewart
    Martin, Georg
    Rodriguez-Ezpeleta, Naiara
    [J]. FRONTIERS IN MARINE SCIENCE, 2016, 3
  • [10] Continuous wavelet filtering on webcam photoplethysmographic signals to remotely assess the instantaneous heart rate
    Bousefsaf, Frederic
    Maaoui, Choubeila
    Pruski, Alain
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (06) : 568 - 574