C1 lateral mass screw insertion caudally from C2 nerve root - An alternate method for insertion of C1 screws: A technical note and preliminary clinical results

被引:10
|
作者
Wada, Keiji [1 ]
Tamaki, Ryo [1 ]
Yui, Mitsuru [1 ]
Numaguchi, Daisuke [1 ]
Murata, Yasuaki [1 ]
机构
[1] Tokyo Womens Med Univ, Dept Orthoped Surg, Tokyo, Japan
关键词
VERTEBRAL ARTERY; POSTERIOR ARCH; C1-C2; FUSION; FIXATION; ATLAS; FEASIBILITY; SUITABILITY; PLACEMENT; COMPLEX; GROOVE;
D O I
10.1016/j.jos.2016.10.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: C1 lateral mass screw was widely used for fixation of the upper cervical spine. However, massive bleeding from the C1-2 venous plexus is sometimes encountered. In this study, we proposed an alternate method for C1 lateral mass screw insertion, which involves insertion of the screws caudally from the C2 nerve root to reduce bleeding from C1-2 venous plexus. Methods: Seven patients with atlantoaxial lesions were included in this study. The mean age at surgery was 65.9 (34-82) years. The mean follow-up period was 23.1 (12-38) months. All patients underwent atlantoaxial fusion with C1 lateral mass screws, which were inserted caudally from the C2 nerve root. All screws were inserted using O-arm based navigation system. Operative time, blood loss, C2 nerve root injury and perioperative complications were investigated. The accuracy of C1 screws and bone union were evaluated using postoperative computed tomography. Results: A total of 13 C1 lateral mass screws were inserted using this method. The mean operative time was 224 (144-305) min. The mean blood loss was 209 (100-357) g. One perioperative complication was observed, which was recurrent laryngeal nerve palsy. There were no vertebral artery or spinal cord injuries. No case of massive bleeding from the C1-2 venous plexus was observed. One patient complained of postoperative occipital neuralgia, which disappeared in 2 weeks. No malposition of C1 lateral mass screws was observed on postoperative computed tomography. Bone union was observed in all patients. Conclusion: The C1 lateral mass screw insertion caudally from the C2 nerve root may become an alternate method for insertion of C1 screws. (C) 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:213 / 217
页数:5
相关论文
共 50 条
  • [31] Guideline for C1 Lateral Mass and C2 Pedicle Screw Choices in Children Younger Than 6 Years
    Fan, Daoyang
    Song, Ruipeng
    Zhang, Min
    Bai, Ruimin
    Li, Yue
    Zhang, Zhen
    Wu, Han
    Wang, Yuqiang
    Zhao, Liang
    Gao, Wenfei
    Dong, Hui
    Liao, Wensheng
    Liu, Yilin
    Zhang, Yi
    Wang, Limin
    Wang, Weidong
    SPINE, 2017, 42 (16) : E949 - E955
  • [32] SAFE ZONE FOR C1 LATERAL MASS SCREWS: ANATOMIC AND RADIOLOGICAL STUDY
    Simsek, Serkan
    Yigitkanli, Kazim
    Turba, Ulku C.
    Comert, Ayhan
    Seckin, Hakan
    Tekdemir, Ibrahim
    Elhan, Alaittin
    NEUROSURGERY, 2009, 65 (06) : 1154 - 1160
  • [33] Chronic C1-C2 Rotatory Subluxation Reduced by C1 Lateral Mass Screws and C2 Translaminar Screws: A Case Report
    Lavelle, William F.
    Palomino, Kathryn
    Badve, Siddharth A.
    Albanese, Stephen A.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2017, 37 (03) : E174 - E177
  • [34] Anatomic Consideration of the C1 Laminar Arch for Lateral Mass Screw Fixation via C1 Lateral Lamina : A Landmark between the Lateral and Posterior Lamina of the C1
    Kim, Jung-Hwan
    Kwak, Dai-Soon
    Han, Seung-Ho
    Cho, Sung-Min
    You, Seung-Hoon
    Kim, Moon-Kyu
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2013, 54 (01) : 25 - 29
  • [35] Posterior atlanto-axial fixation with polyaxial C1 lateral mass screws and C2 pars screws
    M. Payer
    M. Luzi
    E. Tessitore
    Acta Neurochirurgica, 2009, 151 : 223 - 229
  • [36] Clinical and radiological Comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation
    Lee, Sun-Ho
    Kim, Eun Sang
    Sung, Joo-Kyung
    Park, Yeun-Mook
    Eoh, Whan
    JOURNAL OF CLINICAL NEUROSCIENCE, 2010, 17 (07) : 886 - 892
  • [37] Unilateral C1 Lateral Mass and C2 Pedicle Screw Fixation for Atlantoaxial Instability in Rheumatoid Arthritis Patients : Comparison with the Bilateral Method
    Paik, Seung-Chull
    Chun, Hyoung-Joon
    Bak, Koang Hum
    Ryu, Jeil
    Choi, Kyu-Sun
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2015, 57 (06) : 460 - 464
  • [38] Radiographic Evaluation of the Technique for C1 Lateral Mass and C2 Pedicle Screw Fixation in Three Hundred Nineteen Cases
    Wang, Shenglin
    Wang, Chao
    Wood, Kirkham B.
    Yan, Ming
    Zhou, Haitao
    SPINE, 2011, 36 (01) : 3 - 8
  • [39] Posterior C1 lateral mass and C2 pedicle screw internal fixation for atlantoaxial instability
    Xie, Yang
    Li, Zhonghai
    Tang, Hao
    Li, Ming
    Guan, Zhengmao
    JOURNAL OF CLINICAL NEUROSCIENCE, 2009, 16 (12) : 1592 - 1594
  • [40] Is the 4 mm height of the vertebral artery groove really a limitation of C1 pedicle screw insertion?
    Huang, Da-Geng
    He, Si-Min
    Pan, Jun-Wei
    Hui, Hua
    Hu, Hui-Min
    He, Bao-Rong
    Li, Hui
    Zhang, Xue-Fang
    Hao, Ding-Jun
    EUROPEAN SPINE JOURNAL, 2014, 23 (05) : 1109 - 1114