Evaluation of the bactericidal efficacy of three different alcohol hand rubs against 57 clinical isolates of S-aureus

被引:14
作者
Cheeseman, K. E. [1 ]
Denyer, S. P. [1 ]
Hosein, I. K. [2 ]
Williams, G. J. [1 ]
Maillard, J. -Y. [1 ]
机构
[1] Cardiff Univ, Welsh Sch Pharm, Cardiff CF10 3NB, S Glam, Wales
[2] N Middlesex Univ Hosp, NHS Trust, Dept Microbiol, London, England
关键词
Alcohol hand rubs; Bioscreen; Carrier test; Intensive therapy unit; Skin disinfection; Staphylococcus aureus; VIVO;
D O I
10.1016/j.jhin.2009.04.018
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
We tested the efficacy of three alcohol hand rubs (AHRs) used in two local Welsh intensive therapy units (ITUs) against Staphylococcus aureus. The test protocol was based on a carrier test and parameters (concentration, contact time) were chosen following observation of hand-sanitising practices in the ITUs. Following AHR exposure, surviving bacteria were enumerated using a standard plate count method plus a Bioscreen C Microbial Growth Analyser. The AHRs demonstrated variable efficacy against the clinical isolates: the mean log(10) reduction after 10 s exposure to Soft Care Med H5, Cutan and Guest Medical, AHRs was 2.67, 0.696 and 1.96, respectively, and after 30 s exposure was 4.58, 1.74 and 3.60, respectively. Since the average time taken by healthcare workers (HCWs) to rub AHR onto their hands was 11 s and 15 s at the two hospitals, the efficacy of these AHRs may be significantly limited against the S. aureus isolates under the conditions observed in practice. In addition, differences observed in log(10) reduction in bacterial. number post-exposure using the Bioscreen compared to the plate count method provided evidence that S. aureus may be able to recover following Guest Medical AHR treatment within 2 min exposure, whereas after 5 min exposure bacterial, damage caused by the AHR was irreversible. Although the introduction of AHRs improved hand hygiene compliance among HCWs, our observations highlighted that contact time is an important factor to ensure the efficacy of these products. (C) 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 17 条
[1]   AN EPIDEMIOLOGIC-STUDY ASSESSING THE RELATIVE IMPORTANCE OF AIRBORNE AND DIRECT CONTACT TRANSMISSION OF MICROORGANISMS IN A MEDICAL INTENSIVE-CARE UNIT [J].
BAUER, TM ;
OFNER, E ;
JUST, HM ;
JUST, H ;
DASCHNER, FD .
JOURNAL OF HOSPITAL INFECTION, 1990, 15 (04) :301-309
[2]   Typing of Staphylococcus aureus clinical isolates using random amplification of polymorphic DNA method and comparison with antibiotic susceptibility typing [J].
Cheeseman, K. E. ;
Williams, G. J. ;
Maillard, J. -Y. ;
Denyer, S. P. ;
Mahenthiralingam, E. .
JOURNAL OF HOSPITAL INFECTION, 2007, 67 (04) :388-390
[3]   HANDWASHING PRACTICES IN AN INTENSIVE-CARE UNIT - THE EFFECTS OF AN EDUCATIONAL-PROGRAM AND ITS RELATIONSHIP TO INFECTION-RATES [J].
CONLY, JM ;
HILL, S ;
ROSS, J ;
LERTZMAN, J ;
LOUIE, TJ .
AMERICAN JOURNAL OF INFECTION CONTROL, 1989, 17 (06) :330-339
[4]  
*EUR COMM STAND, 1997, EN1276 EUR COMM STAN
[5]  
*EUR COMM STAND, 2001, EN13697 EUR COMM STA
[6]  
*EUR COMM STAND, 1995, 12054 EN EUR COMM ST
[7]  
European Standard, 1997, 1500 EN EUR COMM STA
[8]  
GRIFFITHS C, 2004, HLTH STAT Q, V21, P15
[9]   Compliance and efficacy of hand rubbing during in-hospital practice [J].
Karabay, O ;
Sencan, I ;
Sahin, I ;
Alpteker, H ;
Ozcan, A ;
Oksuz, S .
MEDICAL PRINCIPLES AND PRACTICE, 2005, 14 (05) :313-317
[10]   Limited efficacy of alcohol-based hand gels [J].
Kramer, A ;
Rudolph, P ;
Kampf, G ;
Pittet, D .
LANCET, 2002, 359 (9316) :1489-1490