Surface Charge Accumulation on 500kV Cone-Type GIS Spacer under Residual DC Voltage

被引:18
|
作者
Zhou, Hong-yang [1 ]
Ma, Guo-ming [1 ]
Wang, Yuan [1 ]
Li, Cheng-rong [1 ]
Tu, You-Ping [1 ]
Ye, San-pai [2 ]
Zhang, Bo [2 ]
Guo, Xue-feng [2 ]
Yan, Xiang-lian [3 ]
机构
[1] North China Elect Power Univ, Beijing Key Lab High Voltage & EMC, Key Lab Alternate Elect Power Syst Renewable Ener, Beinong Rd 2, Beijing 102206, Peoples R China
[2] Pinggao Grp Co Ltd, Pingdingshan 467001, Peoples R China
[3] China Elect Power Res Inst, High Voltage Res Dept, 15 Xiaoying East Rd, Beijing 100192, Peoples R China
关键词
DC residual voltage; 500 kV cone-type spacer; surface charge accumulation; flashover test; ELECTRIC CHARGES; SF6; GAS; INSULATORS; SYSTEMS;
D O I
10.1109/TDEI.2018.007144
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years, GIS compact design has gradually been recognized and adopted by the industry. In the trend of the compact design, the insulation performance of the cone-type spacer is getting more and more attention by GIS manufacturers and grid operators and maintenance departments. In particular, under the action of DC residual pressure, the insulation properties of cone-type spacer become the focus of attention of all parties. Based on the field equipment operating conditions, the experimental study of DC residual voltage for the true cone-type spacer insulation performance is significant. In order to obtain the proposed pre-stressed time of DC voltage and distributions of surface charge, for the insulation test of 500 kV cone-type spacer under lightning impulse with DC voltage superimposed. A full scale surface charge measurement platform is build up for 500 kV GIS spacer. Then, long-term DC voltage experiments were carried out to obtain the distributions of surface charge on spacer in stationary state under different voltages. Moreover, the saturation time of surface charge accumulation under different DC electric stress is calculated and discussed. The study results show that (1) the distribution of surface charge on spacer is not uniform. It can be observed that on most areas of 500 kV spacer concave surface is dominated by the electric conduction through the volume with positive charges. (2) The time constant of surface charge accumulation decreases with the residual DC voltage amplitude, it can be estimated that the saturation time of surface charge accumulation on 500 kV cone-type spacer is about 23 h for the residual DC voltage reach to 1.0 p.u. The study results are thought to be helpful to the insulation test of 500 kV cone-type spacer under impulse voltage with a superimposed residual DC voltage.
引用
收藏
页码:1230 / 1237
页数:8
相关论文
共 50 条
  • [31] Surface and Interface Charge Accumulation and Decay of Oil-paper Insulation under DC Voltage
    Du, B. X.
    Zhu, W. B.
    Zhang, J. G.
    Li, X. L.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (02) : 939 - 946
  • [32] Measurement method and accumulation characteristics of surface charge distribution on polymeric material under DC voltage
    Zhang B.
    Wang Q.
    Qi Z.
    Zhang G.
    Zhang, Guixin (guixin@mail.tsinghua.edu.cn), 1600, Chinese Society for Electrical Engineering (36): : 6664 - 6674
  • [33] Understanding the effect of SiC/epoxy coating on surface flashover under DC voltage: from surface charge accumulation
    Han, Pu
    Pan, Zijun
    Mao, Shiyi
    Ye, Yuhan
    Tang, Ju
    Pan, Cheng
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2023, 56 (40)
  • [34] Surface Charge Accumulation on a Real Size Epoxy Insulator With Bouncing Metal Particle Under DC Voltage
    Gao, Yu
    Wang, Huan
    Yuan, Xiaochen
    Zhao, Huicun
    Li, Ziyi
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2021, 49 (07) : 2166 - 2175
  • [35] Experimental Investigation of Surface Charge Accumulation Behaviors on PTFE Insulator under DC and Impulse Voltage in Vacuum
    Su, Guo-Qiang
    Wang, Yi-Bo
    Guo, Bao-Hong
    Song, Bai-Peng
    Mu, Hai-Bao
    Zhang, Guan-Jun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (06) : 3347 - 3356
  • [36] Effect of Insulation Distance on Surface Charge Accumulation at the Gas-Solid Interface Under DC Voltage
    Han, Pu
    Pan, Cheng
    Pan, Zijun
    Ye, Yuhan
    Qiu, Yujie
    Mao, Shiyi
    Tang, Ju
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (06) : 3140 - 3149
  • [37] Surface Charge Accumulation Behavior on GIL Spacer Under DC Voltages in SF6/N2 Mixtures
    Li, Ke-Feng
    Liu, Yan-Qin
    Fan, Xiao-Feng
    Liu, Xiang-Yu
    Xue, Jian-Yi
    Deng, Jun-Bo
    Zhang, Guan-Jun
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [38] Influence of Bouncing Metal Particle on Surface Charge Accumulation of A Real Size Epoxy Insulator under DC Voltage
    Wang, Huan
    Gao, Yu
    Li, Zhijian
    Chen, Rong
    Yuan, Xiaochen
    Han, Tao
    PROCEEDINGS OF THE 2020 3RD IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD 2020), 2020, : 467 - 470
  • [39] Metal nanoparticle-doped epoxy resin to suppress surface charge accumulation on insulators under DC voltage
    Wang, Tian-Yu
    Zhang, Bo-Ya
    Li, Da-Yu
    Hou, Yi-Cen
    Zhang, Gui-Xin
    NANOTECHNOLOGY, 2020, 31 (32)
  • [40] Surface Charge Accumulation and Suppression on Fullerene-filled Epoxy-resin Insulator under DC Voltage
    Zhang, Boya
    Gao, Wenqiang
    Hou, Yicen
    Zhang, Guixin
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (05) : 2011 - 2019