Comparative evaluation of an automated preloaded delivery system with a non-preloaded system

被引:0
作者
Joshi, Rajesh S. [1 ]
机构
[1] Govt Med Coll, Dept Ophthalmol, Nagpur, Maharashtra, India
基金
英国科研创新办公室;
关键词
Automated intraocular IOL delivery system; intraocular lens; phacoemulsification; preloaded intraocular IOL delivery system; semipreloaded IOL delivery system; INTRAOCULAR-LENS; CATARACT-SURGERY; IMPLANTATION; ENDOPHTHALMITIS; SURFACE;
D O I
10.4103/ijo.IJO_1635_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate a single surgeon's experience with an automated preloaded intraocular lens (IOL) delivery system and a nonpreloaded system. Methods: This was a prospective, observational case series. Phacoemulsification was performed under topical anesthesia by creating a temporal clear corneal incision. Patients were consecutively assigned to either the Clareon group (n = 50; the IOL was injected into the capsular bag by using an automated injector system) or the AcrySof group (n = 50; the IOL was injected into the capsular bag by using a conventional injector system). The main outcome measures were ease of implantation, intraoperative complications, postoperative centration, and visual acuity. Results: Additional manipulation in the anterior chamber was not required in 38 (74%) eyes in the Clareon group and 41 (82%) eyes in the AcrySof group. However, seven eyes in the Clareon group and one eye in the AcrySof group required trailing haptic dislodgement from the optic. Furthermore, two eyes in the Clareon group and five eyes in the AcrySof group required injector rotation (varying from 10 degrees to 90 degrees) in the wound. Moreover, in two eyes of the Clareon group, the silicon plunger of the injector system crossed over the optic. None of the patients developed iris trauma and PCR during IOL manipulation. All the IOLs were centered in the capsular bag. Conclusion: The automated IOL delivery system enables the controlled delivery of an IOL in the capsular bag. The effect of carbon footprints created by plastic generated from the delivery system and the implications of the COy(2) cylinder on the environment should be addressed.
引用
收藏
页码:4307 / 4311
页数:5
相关论文
共 35 条
  • [31] Refractive stability of a new single-piece hydrophobic acrylic intraocular lens and corneal wound repair after implantation using a new automated intraocular lens delivery system
    Negishi, Kazuno
    Masui, Sachiko
    Torii, Hidemasa
    Nishi, Yasuyo
    Tsubota, Kazuo
    PLOS ONE, 2020, 15 (09):
  • [32] Clinical evaluation of aqueous outflow system in vivo and correlation with intraocular pressure before and after non-penetrating glaucoma surgery
    Vaiciuliene, Renata
    Koerber, Norbert
    Jasinskas, Vytautas
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (05) : 2141 - 2147
  • [33] Evaluation of the Svelte Medical systems SLENDER IDS Sirolimus-eluting coronary stent-on-a-wire integrated delivery system for the treatment of coronary artery disease
    Verheye, Stefan
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (09) : 669 - 683
  • [34] A dual-mediated liposomal drug delivery system targeting the brain: rational construction, integrity evaluation across the blood-brain barrier, and the transporting mechanism to glioma cells
    Liu, Chang
    Liu, Xiao-Na
    Wang, Gui-Ling
    Hei, Yu
    Meng, Shuai
    Yang, Ling-Fei
    Yuan, Lan
    Xie, Ying
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 : 2407 - 2425
  • [35] Optical Coherence Tomographic Results at Six-Month Follow-Up Evaluation of the CATANIA Coronary Stent System With NanoThin Polyzene-F Surface Modification (from the Assessment of The LAtest Non-Thrombogenic Angioplasty Stent [ATLANTA] Trial)
    La Manna, Alessio
    Capodanno, Davide
    Cera, Maria
    Di Salvo, Maria Elena
    Sacchetta, Giorgio
    Corcos, Thierry
    Prati, Francesco
    Tamburino, Corrado
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (11) : 1551 - 1555