Comparative evaluation of an automated preloaded delivery system with a non-preloaded system

被引:0
|
作者
Joshi, Rajesh S. [1 ]
机构
[1] Govt Med Coll, Dept Ophthalmol, Nagpur, Maharashtra, India
关键词
Automated intraocular IOL delivery system; intraocular lens; phacoemulsification; preloaded intraocular IOL delivery system; semipreloaded IOL delivery system; INTRAOCULAR-LENS; CATARACT-SURGERY; IMPLANTATION; ENDOPHTHALMITIS; SURFACE;
D O I
10.4103/ijo.IJO_1635_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate a single surgeon's experience with an automated preloaded intraocular lens (IOL) delivery system and a nonpreloaded system. Methods: This was a prospective, observational case series. Phacoemulsification was performed under topical anesthesia by creating a temporal clear corneal incision. Patients were consecutively assigned to either the Clareon group (n = 50; the IOL was injected into the capsular bag by using an automated injector system) or the AcrySof group (n = 50; the IOL was injected into the capsular bag by using a conventional injector system). The main outcome measures were ease of implantation, intraoperative complications, postoperative centration, and visual acuity. Results: Additional manipulation in the anterior chamber was not required in 38 (74%) eyes in the Clareon group and 41 (82%) eyes in the AcrySof group. However, seven eyes in the Clareon group and one eye in the AcrySof group required trailing haptic dislodgement from the optic. Furthermore, two eyes in the Clareon group and five eyes in the AcrySof group required injector rotation (varying from 10 degrees to 90 degrees) in the wound. Moreover, in two eyes of the Clareon group, the silicon plunger of the injector system crossed over the optic. None of the patients developed iris trauma and PCR during IOL manipulation. All the IOLs were centered in the capsular bag. Conclusion: The automated IOL delivery system enables the controlled delivery of an IOL in the capsular bag. The effect of carbon footprints created by plastic generated from the delivery system and the implications of the COy(2) cylinder on the environment should be addressed.
引用
收藏
页码:4307 / 4311
页数:5
相关论文
共 35 条
  • [1] Preloaded and non-preloaded intraocular lens delivery system and characteristics: human and porcine eyes trial
    Chung, Byunghoon
    Lee, Hun
    Choi, Moonjung
    Seo, Kyoung Yul
    Kim, Eung Kweon
    Kim, Tae-im
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (01) : 6 - 11
  • [2] Clinical Evaluation of a Novel Preloaded Intraocular Lens Delivery System During Routine Cataract Surgery
    Black, Daniel
    Corbett, Dean
    Roberts, Timothy V.
    Cronin, Brendan
    Smith, Pamela J.
    Janakiraman, D. Priya
    Jackson, Beth E.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 2291 - 2300
  • [3] In vitro delivery performance assessment of a new preloaded intraocular lens delivery system
    Wang, Lixin
    Wolfe, Patricia
    Chernosky, Alexis
    Paliwal, Sumit
    Tjia, Khiun
    Lane, Stephen
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (12): : 1814 - 1820
  • [4] Multicenter Evaluation of Time, Operational, and Economic Efficiencies of a New Preloaded Intraocular Lens Delivery System versus Manual Intraocular Lens Delivery
    Mendicute, Javier
    Bascaran, Lucia
    Pablo, Luis
    Schweitzer, Cedric
    Velasque, Laurent
    Bouchet, Christine
    Martinez, Aldo A.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 591 - 599
  • [5] Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery
    Acar, Banu
    Torun, Isil M.
    Acar, Suphi
    OPEN OPHTHALMOLOGY JOURNAL, 2018, 12 : 94 - 103
  • [6] Comparative assessment of the corneal incision enlargement of 4 preloaded IOL delivery systems
    Liu, Jingbo
    Wolfe, Patricia
    Hernandez, Victor
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (07): : 1041 - 1046
  • [7] Comparative evaluation of corneal incision enlargement after intraocular lens delivery of new preloaded and manual implantation systems
    Wang, Lixin
    Wolfe, Patricia
    Paliwal, Sumit
    Chernosky, Alexis
    Kohnen, Thomas
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (01) : 83 - 87
  • [8] Delivery Characteristics of the Preloaded POB-MA 877PA Intraocular Lens System: Comparison of 2 Incision Sizes
    Yao, Anthony
    Liu, Henry
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2019, 8 (03): : 233 - 235
  • [9] Comparison of incision size and intraocular lens performance after implantation with three preloaded systems and one manual delivery system
    Mendicute, Javier
    Amzallag, Thierry
    Wang, Lixin
    Martinez, Aldo A.
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 1495 - 1503
  • [10] Intraocular Lens Delivery Characteristics of the Preloaded AcrySof IQ SN60WS/AcrySert Injectable Lens System
    Ong, Hon Shing
    Subash, Malavika
    Sandhu, Amanjeet
    Wilkins, Mark R.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (01) : 77 - 81