Thermodynamic analysis of CO2 separation from biogas with conventional ionic liquids

被引:20
作者
Zhang, Yingying [1 ]
Ji, Xiaoyan [2 ]
Xie, Yujiao [3 ]
Lu, Xiaohua [4 ]
机构
[1] Zhengzhou Univ Light Ind, Dept Mat & Chem Engn, Zhengzhou 450002, Henan, Peoples R China
[2] Lulea Univ Technol, Div Energy Sci, Energy Engn, S-97187 Lulea, Sweden
[3] Shandong Univ Technol, Sch Chem Engn, Zibo 255091, Peoples R China
[4] Nanjing Tech Univ, State Key Lab Mat Oriented Chem Engn, Nanjing 210009, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
CO2; separation; Ionic liquids; Thermodynamic analysis; Gibbs free energy change; IL needed; Energy use; CARBON-DIOXIDE SOLUBILITY; ENERGY-CONSUMPTION ANALYSIS; LOW-PRESSURE SOLUBILITIES; HEAT-CAPACITIES; PHASE-BEHAVIOR; THERMOPHYSICAL PROPERTIES; REFRACTIVE-INDEX; INFINITE DILUTION; EXCESS PROPERTIES; GAS SOLUBILITIES;
D O I
10.1016/j.apenergy.2018.02.079
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
CO2 separation plays an important role in energy saving and CO2 emission reduction to address global warming. Ionic liquids (ILs) have been proposed as potential absorbents for CO2 separation, and a large amount of ILs have been synthesized to achieve this purpose. To screen ILs for CO2 separation, CO2 absorption capacity/selectivity and energy use have been considered, whereas the required amount of IL has been seldom involved. In this work, CO2 separation from biogas with 30 conventional Its was analyzed theoretically on the basis of the Gibbs free energy change combining the amount of IL needed and the energy use. The desorption temperature was estimated from the absorption pressure, and then the amount of IL needed and the energy use were calculated. Thermodynamic analysis shows that the absorption pressure and the desorption temperature need to be changed to achieve optimal separation. Several ILs were screened with certain criteria, namely, the amount of IL needed and energy use. The performance of the screened ILs was compared with that of commercial CO2 absorbents (30 wt% MEA, 30 wt% MDEA, DEPG, and water). The comparison with DEPG and water shows that the screened physical ILs are promising for IL-based technologies because of their advantages of negligible vaporization enthalpy, low amount of absorbent needed, or low energy use. A comparison with 30 wt% MEA and 30 wt% MDEA indicates that chemical IL has negligible vaporization enthalpy and low energy use. These findings show that the screened ILs are promising for CO2 separation from biogas.
引用
收藏
页码:75 / 87
页数:13
相关论文
共 127 条
[51]   Solubility of CO2 in the ionic liquids [bmim][CH3SO4] and [bmim][PF6] [J].
Kumelan, Jacek ;
Kamps, Alvaro Perez-Salado ;
Tuma, Dirk ;
Maurer, Gerd .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2006, 51 (05) :1802-1807
[52]   Solubility of single gases carbon dioxide and hydrogen sulfide in aqueous solutions of N-methyldiethanolamine in the temperature range 313-413 K at pressures up to 5 MPa [J].
Kuranov, G ;
Rumpf, B ;
Smirnova, NA ;
Maurer, G .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1996, 35 (06) :1959-1966
[53]  
LEE JI, 1976, J APPL CHEM BIOTECHN, V26, P541
[54]   Metallic copper incorporated ionic liquids toward maximizing CO2 separation properties [J].
Lee, Jung Hyun ;
Chae, Il Seok ;
Song, Donghoon ;
Kang, Yong Soo ;
Kang, Sang Wook .
SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 112 :49-53
[55]   Physicochemical Properties of [C6mim][PF6] and [C6mim][(C2F5)3PF3] Ionic Liquids [J].
Li, Ji-Guang ;
Hu, Yu-Feng ;
Ling, Shan ;
Zhang, Jin-Zhu .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2011, 56 (07) :3068-3072
[56]   Density, dynamic viscosity, and electrical conductivity of pyridinium-based hydrophobic ionic liquids [J].
Liu, Qing-Shan ;
Li, Pei-Pei ;
Welz-Biermann, Urs ;
Chen, Jian ;
Liu, Xiao-Xia .
JOURNAL OF CHEMICAL THERMODYNAMICS, 2013, 66 :88-94
[57]   CO2 capture by membrane absorption coupling process: Application of ionic liquids [J].
Lu, Jian-Gang ;
Lu, Chun-Ting ;
Chen, Yue ;
Gao, Liu ;
Zhao, Xin ;
Zhang, Hui ;
Xu, Zheng-Wen .
APPLIED ENERGY, 2014, 115 :573-581
[58]   An overview of CO2 capture technologies [J].
MacDowell, Niall ;
Florin, Nick ;
Buchard, Antoine ;
Hallett, Jason ;
Galindo, Amparo ;
Jackson, George ;
Adjiman, Claire S. ;
Williams, Charlotte K. ;
Shah, Nilay ;
Fennell, Paul .
ENERGY & ENVIRONMENTAL SCIENCE, 2010, 3 (11) :1645-1669
[59]   On the High-Pressure Solubilities of Carbon Dioxide in Several Ionic Liquids [J].
Mejia, Isabel ;
Stanley, Kathleen ;
Canales, Roberto ;
Brennecke, Joan F. .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2013, 58 (09) :2642-2653
[60]   CO2 capture in power plants: Minimization of the investment and operating cost of the post-combustion process using MEA aqueous solution [J].
Mores, Patricia ;
Rodriguez, Nestor ;
Scenna, Nicolas ;
Mussati, Sergio .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2012, 10 :148-163