Bony ingrowth potential of 3D-printed porous titanium alloy: a direct comparison of interbody cage materials in an in vivo ovine lumbar fusion model

被引:177
作者
McGilvray, Kirk C. [1 ,2 ]
Easley, Jeremiah [3 ]
Seim, Howard B. [3 ]
Regan, Daniel [1 ,2 ]
Berven, Sigurd H. [4 ]
Hsu, Wellington K. [5 ]
Mroz, Thomas E. [6 ]
Puttlitz, Christian M. [1 ,2 ]
机构
[1] Colorado State Univ, Orthopaed Bioengn Res Lab, Dept Mech Engn, 1374 Campus Delivery,200 W Lake St, Ft Collins, CO 80523 USA
[2] Colorado State Univ, Sch Biomed Engn, 1374 Campus Delivery,200 W Lake St, Ft Collins, CO 80523 USA
[3] Colorado State Univ, PSRL, 300 W Drake Rd, Ft Collins, CO 80525 USA
[4] Univ Calif San Francisco, Dept Orthoped Surg, San Francisco, CA 94142 USA
[5] Northwestern Univ, Feinberg Sch Med, 420 E Super St, Chicago, IL 60611 USA
[6] Cleveland Clin, 9500 Euclid Ave, Cleveland, OH 44195 USA
关键词
3D porous titanium; Interbody cage; Ovine; PEEK; Spine; Spine fusion; POLYETHERETHERKETONE PEEK; CIRCUMFERENTIAL FUSION; POSTEROLATERAL FUSION; HUMAN SPINE; OSSEOINTEGRATION; IMPLANTS; COATINGS; METAANALYSIS; ARTHRODESIS; ANATOMY;
D O I
10.1016/j.spinee.2018.02.018
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: There is significant variability in the materials commonly used for interbody cages in spine surgery. It is theorized that three-dimensional (3D)-printed interbody cages using porous titanium material can provide more consistent bone ingrowth and biological fixation. PURPOSE: The purpose of this study was to provide an evidence-based approach to decision-making regarding interbody materials for spinal fusion. STUDY DESIGN: A comparative animal study was performed. METHODS: A skeletally mature ovine lumbar fusion model was used for this study. Interbody fissions were performed at L2-L3 and L4-L5 in 27 mature sheep using three different interbody cages (ie, polyetheretherketone [PEEK], plasma sprayed porous titanium-coated PEEK [PSP], and 3D-printed porous titanium alloy cage [PTA]). Non-destructive kinematic testing was performed in the three primary directions of motion. The specimens were then analyzed using micro-computed tomography (mu-CT); quantitative measures of the bony fusion were performed. Histomorphometric analyses were also performed in the sagittal plane through the interbody device. Outcome parameters were compared between cage designs and time points. RESULTS: Flexion-extension range of moron (ROM) was statistically reduced for the PTA group compared with the PEEK cages at 16 weeks (p-value =.02). Only the PTA cages demonstrated a statistically significant decrease in ROM and increase in stiffness across all three loading directions between the 8-week and 16-week sacrifice time points (p-value <=.01). Micro-CT data demonstrated significantly greater total bone volume within the graft window for the PTA cages at both 8 weeks and 16 weeks compared with the PEEK cages (p-value<.01). CONCLUSIONS: A direct comparison of interbody implants demonstrates significant and measurable differences in biomechanical, mu-CT, and histologic performance in an ovine model. The 3D-printed porous titanium interbody cage resulted in statistically significant reductions in ROM, increases in the bone ingrowth profile, as well as average construct stiffness compared with PEEK and PSl. (C) 2018 The Authors. Published by Elsevier Inc.
引用
收藏
页码:1250 / 1260
页数:11
相关论文
共 42 条
[1]  
BAGBY GW, 1988, ORTHOPEDICS, V11, P931
[2]  
Cunningham Bryan W, 2003, Spine J, V3, P19, DOI 10.1016/S1529-9430(02)00443-6
[3]   The effect of titanium particulate on development and maintenance of a posterolateral spinal arthrodesis -: An in vivo rabbit model [J].
Cunningham, BW ;
Orbegoso, CM ;
Dmitriev, AE ;
Hallab, NJ ;
Sefter, JC ;
McAfee, PC .
SPINE, 2002, 27 (18) :1971-1981
[4]  
De Leonardis D, 1999, INT J ORAL MAX IMPL, V14, P384
[5]   An analysis of fusion cage migration in unilateral and bilateral fixation with transforaminal lumbar interbody fusion [J].
Duncan, Jan William ;
Bailey, Richard Anthony .
EUROPEAN SPINE JOURNAL, 2013, 22 (02) :439-445
[6]   Partial gravity unloading inhibits bone healing responses in a large animal model [J].
Gadomski, Benjamin C. ;
McGilvray, Kirk C. ;
Easley, Jeremiah T. ;
Palmer, Ross H. ;
Santoni, Brandon G. ;
Puttlitz, Christian M. .
JOURNAL OF BIOMECHANICS, 2014, 47 (12) :2836-2842
[7]   An In Vivo Ovine Model of Bone Tissue Alterations in Simulated Microgravity Conditions [J].
Gadomski, Benjamin C. ;
McGilvray, Kirk C. ;
Easley, Jeremiah T. ;
Palmer, Ross H. ;
Ehrhart, E. J. ;
Haussler, Kevin K. ;
Browning, Raymond C. ;
Santoni, Brandon G. ;
Puttlitz, Christian M. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (02)
[8]   Evaluating Osseointegration Into a Deeply Porous Titanium Scaffold A Biomechanical Comparison With PEEK and Allograft [J].
Guyer, Richard D. ;
Abitbol, Jean-Jacques ;
Ohnmeiss, Donna D. ;
Yao, Chang .
SPINE, 2016, 41 (19) :E1146-E1150
[9]   Surface activation of polyetheretherketone (PEEK) and formation of calcium phosphate coatings by precipitation [J].
Ha, SW ;
Kirch, M ;
Birchler, F ;
Eckert, KL ;
Mayer, J ;
Wintermantel, E ;
Sittig, C ;
PfundKlingenfuss, I ;
Textor, M ;
Spencer, ND ;
Guecheva, M ;
Vonmont, H .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (11) :683-690
[10]   The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties [J].
Han, Cheol-Min ;
Lee, Eun-Jung ;
Kim, Hyoun-Ee ;
Koh, Young-Hag ;
Kim, Keung N. ;
Ha, Yoon ;
Kuh, Sung-Uk .
BIOMATERIALS, 2010, 31 (13) :3465-3470