Motion mitigation in scanned ion beam therapy through 4D-optimization

被引:75
作者
Graeff, Christian [1 ]
机构
[1] GSI Helmholzzentrum Schwerionenforsch GmbH, Darmstadt, Germany
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2014年 / 30卷 / 05期
关键词
Treatment planning; 4D-optimization; Motion mitigation; Intrafractional motion; BREATHING-SYNCHRONIZED DELIVERY; MODULATED ARC THERAPY; PARTICLE THERAPY; RESPIRATORY MOTION; TRACKING SYSTEM; TUMOR MOTION; PROTON-BEAM; RADIOTHERAPY; OPTIMIZATION; MANAGEMENT;
D O I
10.1016/j.ejmp.2014.03.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The treatment of moving tumors remains challenging, especially with scanned ion beam therapy due to interplay effects and the strong range dependence. This is especially true in the context of radiosurgery with high dose delivered in few or single fractions. Inverse treatment planning on the entire 4D-CT may result in conformal plans inherently adapted to the moving anatomy of the patient. Existing studies on this topic for photon therapy are reviewed, but arguably the benefits for ion beam therapy can be even greater. Compared to the main conformal mitigation technique of beam tracking, 4D-optimization permits a) easier, offline handling of range changes, b) handling of complex motion patterns, and c) improved dose shaping capabilities outside of the target. Different approaches for 4D-optimization in scanned ion beam therapy are proposed and compared, together with delivery methods that provide the necessary synchronization between irradiation and detected patient motion. Potential solutions for the improvement of robustness in 4D-optimization are discussed. A method for delivery of homogenous doses to each motion phase is presented that might be a potential solution for robust conformal dose delivery for future clinical use. In an exemplary lung cancer patient case with a large motion amplitude, 4D-optimization resulted in conformal dose coverage while beam tracking did not. In conclusion, different strategies of 4D-optimization could provide increased OAR sparing and highly conformal dose delivery for targets with complex motion patterns and large amplitudes. (C) 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:570 / 577
页数:8
相关论文
共 50 条
  • [1] A 4D-optimization concept for scanned ion beam therapy
    Graeff, Christian
    Luechtenborg, Robert
    Eley, John Gordon
    Durante, Marco
    Bert, Christoph
    RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) : 419 - 424
  • [2] Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy
    Richter, D.
    Schwarzkopf, A.
    Trautmann, J.
    Kraemer, M.
    Durante, M.
    Jaekel, O.
    Bert, C.
    MEDICAL PHYSICS, 2013, 40 (05)
  • [3] Multigating, a 4D Optimized Beam Tracking in Scanned Ion Beam Therapy
    Graeff, Christian
    Constantinescu, Anna
    Luechtenborg, Robert
    Durante, Marco
    Bert, Christoph
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2014, 13 (06) : 497 - 504
  • [4] 4D optimization of scanned ion beam tracking therapy for moving tumors
    Eley, John Gordon
    Newhauser, Wayne David
    Luechtenborg, Robert
    Graeff, Christian
    Bert, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (13) : 3431 - 3452
  • [5] A 4D dose computation method to investigate motion interplay effects in scanned ion beam prostate therapy
    Ammazzalorso, F.
    Jelen, U.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (11) : N91 - N99
  • [6] Residual motion mitigation in scanned carbon ion beam therapy of liver tumors using enlarged pencil beam overlap
    Richter, Daniel
    Graeff, Christian
    Jaekel, Oliver
    Combs, Stephanie E.
    Durante, Marco
    Bert, Christoph
    RADIOTHERAPY AND ONCOLOGY, 2014, 113 (02) : 290 - 295
  • [7] Motion management with phase-adapted 4D-optimization
    Nohadani, Omid
    Seco, Joao
    Bortfeld, Thomas
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (17) : 5189 - 5202
  • [8] Fast optimization and dose calculation in scanned ion beam therapy
    Hild, S.
    Graeff, C.
    Trautmann, J.
    Kraemer, M.
    Zink, K.
    Durante, M.
    Bert, C.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [9] Management of organ motion in scanned ion beam therapy
    Bert, Christoph
    Herfarth, Klaus
    RADIATION ONCOLOGY, 2017, 12
  • [10] Scanned ion beam therapy for prostate carcinoma
    Hild, Sebastian
    Graeff, Christian
    Rucinski, Antoni
    Zink, Klemens
    Habl, Gregor
    Durante, Marco
    Herfarth, Klaus
    Bert, Christoph
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (02) : 118 - 126