Retrospective study of patients radiation dose during cardiac catheterization procedures

被引:11
|
作者
Osei, Beverley [1 ,2 ]
Xu, Lu [2 ,3 ]
Johnston, Amanda [4 ]
Darko, Sara [5 ]
Darko, Johnson [2 ,6 ,7 ]
Osei, Ernest [2 ,6 ,7 ,8 ]
机构
[1] McMaster Univ, Dept Hlth Sci, Hamilton, ON, Canada
[2] Grand River Reg Canc Ctr, Dept Med Phys, Kitchener, ON, Canada
[3] Western Univ, Dept Med Sci IMS & Med Biophys, London, ON, Canada
[4] St Mary Gen Hosp, Kitchener, ON, Canada
[5] Grand River Reg Canc Ctr, Dept Clin Trials, Kitchener, ON, Canada
[6] Univ Waterloo, Dept Phys & Astron, Waterloo, ON, Canada
[7] Univ Guelph, Ontario Vet Coll, Dept Clin Studies, Guelph, ON, Canada
[8] Univ Waterloo, Dept Syst Design Engn, Waterloo, ON, Canada
关键词
FLUOROSCOPICALLY GUIDED PROCEDURES; CORONARY-ANGIOGRAPHY; INTERVENTIONAL CARDIOLOGY; SKIN INJURIES; EXPOSURE; SAFETY; RISK; IMPLANTATION; ARTERIES; VALUES;
D O I
10.1259/bjr.20181021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Cardiac catheterization procedures provide tremendous benefits to modern healthcare and the benefit derived by the patient should far outweigh the radiation risk associated with a properly optimized procedure. With increasing utilization of such procedures, there is growing concern regarding the magnitude and variations of dose to patients associated with procedure complexity and techniques parameters. Therefore, this study investigated radiation dose to patients from six cardiac catheterization procedures at our facility and suggest possible initial dose values for benchmark for patient radiation dose from these procedures. This initial benchmark data will be used for clinical radiation dose management which is essential for assessing the impact of any quality improvement initiatives in the cardiac catheterization laboratory. Methods: We retrospectively analyzed the dose parameters of 1000 patients who underwent various cardiac catheterization procedures: left heart catheterization (LH), percutaneous coronary intervention (PCI), complex PCI, LH with complex PCI, LH with PCI and cardiac resynchronization therapy (CRT) pacemaker in our cardiac catheterization laboratories. Patient's clinical radiation dose data [kerma-area-product (KAP) and air-kerma at the interventional reference point (K-a,K-r)] and technique parameters (fluoroscopy time, tube potential, current, pulse width and number tine images) along with demographic information (age, height and weight) were collected from the hospital's RIS (Synapse), Sensis/Syngo Dynamics and Siemens Sensis Stats Manager electronic database. Statistical analysis was performed with the IBM SPSS Modeler v. 18.1 software. Results: The overall patient median age was 67.0 (range: 26.0-97.0) years and the median body mass index (BMI) was 28.8 (range: 15.9-61.7) kg/m(2) The median KAP for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 44.4 (4.1-203.2), 80.2 (18.9-208.5), 83.7 (48.0-246.1), 113.8 (60.9-284.5), 91.7 (6.0-426.0) and 51.1 (7.0-175.9) Gy-cm(2) The median K-a,K-r for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 701.0 (35.3-3794.0), 1384.7 (291.7-4021.8), 1607.0 (883.5-4448.3), 2260.2 (867.4-5311.9), 1589.3 (100.2-7237.4) and 463.8 (67.7-1695.9) mGy respectively. Conclusion: We have analyzed patient radiation doses from six commonly used procedures in our cardiac catheterization laboratories and suggested possible initial values for benchmark from these procedures for the fluoroscopy time, KAP and air-kerma at the interventional reference point based on our current practices. Our data compare well with published values reported in the literature by investigators who have also studied patient doses and established benchmark dose levels for their facilities. Procedure-specific benchmark dose data for various groups of patients can provide the motivation for monitoring practices to promote improvements in patient radiation dose optimization in the cardiac catheterization laboratories. Advances in knowledge: We have investigated local patients' radiation doses and established benchmark radiation data which are essential for assessing the impact of any quality improvement initiatives for radiation dose optimization.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] The role of a commercial radiation dose index monitoring system in establishing local dose reference levels for fluoroscopically guided invasive cardiac procedures
    Zucca, Sergio
    Solla, Ignazio
    Boi, Alberto
    Loi, Stefano
    Rossi, Angelica
    Sanna, Francesco
    Loi, Bruno
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 74 : 11 - 18
  • [42] Study of radiation doses to personnel in a cardiac catheterization laboratory
    McKetty, MH
    HEALTH PHYSICS, 1996, 70 (04): : 563 - 567
  • [43] Radiation dose benchmarks in pediatric cardiac catheterization: A prospective multi-center C3PO-QI study
    Cevallos, Priscila C.
    Armstrong, Aimee K.
    Glatz, Andrew C.
    Goldstein, Bryan H.
    Gudausky, Todd M.
    Leahy, Ryan A.
    Petit, Christopher J.
    Shahanavaz, Shabana
    Trucco, Sara M.
    Bergersen, Lisa J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (02) : 269 - 280
  • [44] Fluoroscopy Pulse Rate Reduction during Diagnostic and Therapeutic Imaging in the Cardiac Catheterization Laboratory: An Evaluation of Radiation Dose, Procedure Complications and Outcomes
    Hansen, James W.
    Foy, Andrew
    Schmidt, Torrey
    Ghahramani, Mehrdad
    Chambers, Charles E.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 89 (04) : 665 - 670
  • [45] Radiation exposure during cardiac catheterization: Implications for the transradial approach
    Komocsi, A.
    Konyi, A.
    Kovacs, E.
    Ungi, I.
    INTERVENTIONAL MEDICINE AND APPLIED SCIENCE, 2010, 2 (03) : 105 - 109
  • [46] Surgeon radiation dose during complex endovascular procedures
    Kirkwood, Melissa L.
    Guild, Jeffrey B.
    Arbique, Gary M.
    Anderson, Jon A.
    Valentine, R. James
    Timaran, Carlos
    JOURNAL OF VASCULAR SURGERY, 2015, 62 (02) : 457 - 463
  • [47] Evaluation of patients' and occupational radiation risk dose during conventional and interventional radiology procedures
    Tamam, Nissren
    Salah, H.
    Almogren, Kholoud S.
    Mahgoub, Omer
    Saeed, Mohammed Khalil
    Abdullah, Yousef
    Tai, Duong Thanh
    Omer, Hiba
    Sulieman, Abdelmoneim
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 207
  • [48] Impact of cardiac catheterization timing and contrast media dose on acute kidney injury after cardiac surgery
    Jiang, Wuhua
    Yu, Jiawei
    Xu, Jiarui
    Shen, Bo
    Wang, Yimei
    Luo, Zhe
    Wang, Chunsheng
    Ding, Xiaoqiang
    Teng, Jie
    BMC CARDIOVASCULAR DISORDERS, 2018, 18
  • [49] Incidence, Predictors, and Outcomes of Cardiac Perforation During Pediatric Cardiac Catheterization: a Retrospective Observational Study from the Congenital Cardiac Interventional Study Consortium (CCISC)
    McCrossan, B. A.
    Karayiannis, S.
    Shields, M.
    Nykanen, David
    Forbes, Thomas J.
    Kobayashi, Daisuke
    Kenny, D.
    PEDIATRIC CARDIOLOGY, 2023, 44 (04) : 867 - 872
  • [50] Complications of transseptal catheterization for different cardiac procedures
    Katritsis, George D.
    Siontis, George C. M.
    Giazitzoglou, Eleftherios
    Fragakis, Nikolaos
    Katritsis, Demosthenes G.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (06) : 5352 - 5354