Retrospective study of patients radiation dose during cardiac catheterization procedures

被引:11
|
作者
Osei, Beverley [1 ,2 ]
Xu, Lu [2 ,3 ]
Johnston, Amanda [4 ]
Darko, Sara [5 ]
Darko, Johnson [2 ,6 ,7 ]
Osei, Ernest [2 ,6 ,7 ,8 ]
机构
[1] McMaster Univ, Dept Hlth Sci, Hamilton, ON, Canada
[2] Grand River Reg Canc Ctr, Dept Med Phys, Kitchener, ON, Canada
[3] Western Univ, Dept Med Sci IMS & Med Biophys, London, ON, Canada
[4] St Mary Gen Hosp, Kitchener, ON, Canada
[5] Grand River Reg Canc Ctr, Dept Clin Trials, Kitchener, ON, Canada
[6] Univ Waterloo, Dept Phys & Astron, Waterloo, ON, Canada
[7] Univ Guelph, Ontario Vet Coll, Dept Clin Studies, Guelph, ON, Canada
[8] Univ Waterloo, Dept Syst Design Engn, Waterloo, ON, Canada
关键词
FLUOROSCOPICALLY GUIDED PROCEDURES; CORONARY-ANGIOGRAPHY; INTERVENTIONAL CARDIOLOGY; SKIN INJURIES; EXPOSURE; SAFETY; RISK; IMPLANTATION; ARTERIES; VALUES;
D O I
10.1259/bjr.20181021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Cardiac catheterization procedures provide tremendous benefits to modern healthcare and the benefit derived by the patient should far outweigh the radiation risk associated with a properly optimized procedure. With increasing utilization of such procedures, there is growing concern regarding the magnitude and variations of dose to patients associated with procedure complexity and techniques parameters. Therefore, this study investigated radiation dose to patients from six cardiac catheterization procedures at our facility and suggest possible initial dose values for benchmark for patient radiation dose from these procedures. This initial benchmark data will be used for clinical radiation dose management which is essential for assessing the impact of any quality improvement initiatives in the cardiac catheterization laboratory. Methods: We retrospectively analyzed the dose parameters of 1000 patients who underwent various cardiac catheterization procedures: left heart catheterization (LH), percutaneous coronary intervention (PCI), complex PCI, LH with complex PCI, LH with PCI and cardiac resynchronization therapy (CRT) pacemaker in our cardiac catheterization laboratories. Patient's clinical radiation dose data [kerma-area-product (KAP) and air-kerma at the interventional reference point (K-a,K-r)] and technique parameters (fluoroscopy time, tube potential, current, pulse width and number tine images) along with demographic information (age, height and weight) were collected from the hospital's RIS (Synapse), Sensis/Syngo Dynamics and Siemens Sensis Stats Manager electronic database. Statistical analysis was performed with the IBM SPSS Modeler v. 18.1 software. Results: The overall patient median age was 67.0 (range: 26.0-97.0) years and the median body mass index (BMI) was 28.8 (range: 15.9-61.7) kg/m(2) The median KAP for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 44.4 (4.1-203.2), 80.2 (18.9-208.5), 83.7 (48.0-246.1), 113.8 (60.9-284.5), 91.7 (6.0-426.0) and 51.1 (7.0-175.9) Gy-cm(2) The median K-a,K-r for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 701.0 (35.3-3794.0), 1384.7 (291.7-4021.8), 1607.0 (883.5-4448.3), 2260.2 (867.4-5311.9), 1589.3 (100.2-7237.4) and 463.8 (67.7-1695.9) mGy respectively. Conclusion: We have analyzed patient radiation doses from six commonly used procedures in our cardiac catheterization laboratories and suggested possible initial values for benchmark from these procedures for the fluoroscopy time, KAP and air-kerma at the interventional reference point based on our current practices. Our data compare well with published values reported in the literature by investigators who have also studied patient doses and established benchmark dose levels for their facilities. Procedure-specific benchmark dose data for various groups of patients can provide the motivation for monitoring practices to promote improvements in patient radiation dose optimization in the cardiac catheterization laboratories. Advances in knowledge: We have investigated local patients' radiation doses and established benchmark radiation data which are essential for assessing the impact of any quality improvement initiatives for radiation dose optimization.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Evaluation of radiation dose to pediatric patients during certain special procedures
    Sulieman, A.
    Alzimami, K.
    Elhag, B.
    Babikir, E.
    Alsafi, K.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 267 - 271
  • [32] Radiation safety in the cardiac catheterization laboratory
    Aldridge, HE
    Chisholm, RJ
    Dragatakis, L
    Roy, L
    CANADIAN JOURNAL OF CARDIOLOGY, 1997, 13 (05) : 459 - 467
  • [33] Effective Reduction of Radiation Exposure during Cardiac Catheterization
    Gutierrez-Barrios, Alejandro
    Camacho-Galan, Hugo
    Medina-Camacho, Francisco
    Canadas-Pruano, Dolores
    Jimenez-Moreno, Antonio
    Calle-Perez, German
    Vazquez-Garcia, Rafael
    TEXAS HEART INSTITUTE JOURNAL, 2019, 46 (03): : 167 - 171
  • [34] Radiation protection in the cardiac catheterization laboratory
    Biso, Sylvia Marie R.
    Vidovich, Mladen, I
    JOURNAL OF THORACIC DISEASE, 2020, 12 (04) : 1648 - 1655
  • [35] Evaluation of Effective Dose to Patients Undergoing Cardiac Catheterization
    Sulieman, A. A.
    Joda, H.
    Osman, H.
    Omer, H.
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 512 - +
  • [36] Radiation dose reduction during neuroendovascular procedures
    Morris, Pearse P.
    Geer, Carol P.
    Singh, Jasmeet
    Brinjikji, Waleed
    Carter, Rickey E.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2018, 10 (05) : 486 - 492
  • [37] Standardizing Radiation Dose Reporting in the Pediatric Cardiac Catheterization Laboratory-A Multicenter Study by the CCISC (Congenital Cardiovascular Interventional Study Consortium)
    Kobayashi, Daisuke
    Meadows, Jeffery
    Forbes, Thomas J.
    Moore, Phillip
    Javois, Alexander J.
    Pedra, Carlos A.
    Du, Wei
    Gruenstein, Daniel H.
    Wax, David F.
    Hill, James A.
    Graziano, Joseph N.
    Fagan, Thomas E.
    Mosquera Alvarez, Walter
    Nykanen, David G.
    Divekar, Abhay A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (05) : 785 - 793
  • [38] Radiation exposure to operator and patients during cardiac electrophysiology study, radiofrequency catheter ablation and cardiac device implantation procedures
    Lee, C. H.
    Cho, J. H.
    Park, S. J.
    Kim, J. S.
    On, Y. K.
    Huh, J.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2015, 170 (10): : 787 - 795
  • [39] Radiation Dose Reduction in the Cardiac Catheterization Laboratory Utilizing a Novel Protocol
    Wassef, Anthony W. A.
    Hiebert, Brett
    Ravandi, Amir
    Ducas, John
    Minhas, Kunal
    Vo, Minh
    Kass, Malek
    Parmar, Gurpreet
    Hussain, Farrukh
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (05) : 550 - 557
  • [40] Efficacy of the SEPARPROCATH® radiation drape to reduce radiation exposure during cardiac catheterization: A pilot comparative study
    Patet, Camille
    Ryckx, Nick
    Arroyo, Diego
    Cook, Stephane
    Goy, Jean-Jacques
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 94 (03) : 387 - 391