Retrospective study of patients radiation dose during cardiac catheterization procedures

被引:11
|
作者
Osei, Beverley [1 ,2 ]
Xu, Lu [2 ,3 ]
Johnston, Amanda [4 ]
Darko, Sara [5 ]
Darko, Johnson [2 ,6 ,7 ]
Osei, Ernest [2 ,6 ,7 ,8 ]
机构
[1] McMaster Univ, Dept Hlth Sci, Hamilton, ON, Canada
[2] Grand River Reg Canc Ctr, Dept Med Phys, Kitchener, ON, Canada
[3] Western Univ, Dept Med Sci IMS & Med Biophys, London, ON, Canada
[4] St Mary Gen Hosp, Kitchener, ON, Canada
[5] Grand River Reg Canc Ctr, Dept Clin Trials, Kitchener, ON, Canada
[6] Univ Waterloo, Dept Phys & Astron, Waterloo, ON, Canada
[7] Univ Guelph, Ontario Vet Coll, Dept Clin Studies, Guelph, ON, Canada
[8] Univ Waterloo, Dept Syst Design Engn, Waterloo, ON, Canada
关键词
FLUOROSCOPICALLY GUIDED PROCEDURES; CORONARY-ANGIOGRAPHY; INTERVENTIONAL CARDIOLOGY; SKIN INJURIES; EXPOSURE; SAFETY; RISK; IMPLANTATION; ARTERIES; VALUES;
D O I
10.1259/bjr.20181021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Cardiac catheterization procedures provide tremendous benefits to modern healthcare and the benefit derived by the patient should far outweigh the radiation risk associated with a properly optimized procedure. With increasing utilization of such procedures, there is growing concern regarding the magnitude and variations of dose to patients associated with procedure complexity and techniques parameters. Therefore, this study investigated radiation dose to patients from six cardiac catheterization procedures at our facility and suggest possible initial dose values for benchmark for patient radiation dose from these procedures. This initial benchmark data will be used for clinical radiation dose management which is essential for assessing the impact of any quality improvement initiatives in the cardiac catheterization laboratory. Methods: We retrospectively analyzed the dose parameters of 1000 patients who underwent various cardiac catheterization procedures: left heart catheterization (LH), percutaneous coronary intervention (PCI), complex PCI, LH with complex PCI, LH with PCI and cardiac resynchronization therapy (CRT) pacemaker in our cardiac catheterization laboratories. Patient's clinical radiation dose data [kerma-area-product (KAP) and air-kerma at the interventional reference point (K-a,K-r)] and technique parameters (fluoroscopy time, tube potential, current, pulse width and number tine images) along with demographic information (age, height and weight) were collected from the hospital's RIS (Synapse), Sensis/Syngo Dynamics and Siemens Sensis Stats Manager electronic database. Statistical analysis was performed with the IBM SPSS Modeler v. 18.1 software. Results: The overall patient median age was 67.0 (range: 26.0-97.0) years and the median body mass index (BMI) was 28.8 (range: 15.9-61.7) kg/m(2) The median KAP for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 44.4 (4.1-203.2), 80.2 (18.9-208.5), 83.7 (48.0-246.1), 113.8 (60.9-284.5), 91.7 (6.0-426.0) and 51.1 (7.0-175.9) Gy-cm(2) The median K-a,K-r for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 701.0 (35.3-3794.0), 1384.7 (291.7-4021.8), 1607.0 (883.5-4448.3), 2260.2 (867.4-5311.9), 1589.3 (100.2-7237.4) and 463.8 (67.7-1695.9) mGy respectively. Conclusion: We have analyzed patient radiation doses from six commonly used procedures in our cardiac catheterization laboratories and suggested possible initial values for benchmark from these procedures for the fluoroscopy time, KAP and air-kerma at the interventional reference point based on our current practices. Our data compare well with published values reported in the literature by investigators who have also studied patient doses and established benchmark dose levels for their facilities. Procedure-specific benchmark dose data for various groups of patients can provide the motivation for monitoring practices to promote improvements in patient radiation dose optimization in the cardiac catheterization laboratories. Advances in knowledge: We have investigated local patients' radiation doses and established benchmark radiation data which are essential for assessing the impact of any quality improvement initiatives for radiation dose optimization.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Cardiac Catheterization Procedures in Patients with HIV: A Retrospective Analysis
    Ebner, Bertrand
    Vincent, Louis
    Grant, Jelani
    Martinez, Claudia
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2021, 8 (04)
  • [2] Radiation Dose to the Pediatric Cardiac Catheterization and Intervention Patient
    Chida, Koichi
    Ohno, Tadayuki
    Kakizaki, Shuhei
    Takegawa, Mika
    Yuuki, Hiroko
    Nakada, Mitsuru
    Takahashi, Shoki
    Zuguchi, Masayuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1175 - 1179
  • [3] Factors contributing to radiation dose for patients and operators during diagnostic cardiac angiography
    Crowhurst, James A.
    Whitby, Mark
    Savage, Michael
    Murdoch, Dale
    Robinson, Brendan
    Shaw, Elizabeth
    Gaikwad, Niranjan
    Saireddy, Ramkrishna
    Hay, Karen
    Walters, Darren L.
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2019, 66 (01) : 20 - 29
  • [4] Effect of a Real-Time Radiation Monitoring Device on Operator Radiation Exposure During Cardiac Catheterization The Radiation Reduction During Cardiac Catheterization Using Real-Time Monitoring Study
    Christopoulos, Georgios
    Papayannis, Aristotelis C.
    Alomar, Mohammed
    Kotsia, Anna
    Michael, Tesfaldet T.
    Rangan, Bavana V.
    Roesle, Michele
    Shorrock, Deborah
    Makke, Lorenza
    Layne, Ronald
    Grabarkewitz, Rebecca
    Haagen, Donald
    Maragkoudakis, Spyros
    Mohammad, Atif
    Sarode, Karan
    Cipher, Daisha J.
    Chambers, Charles E.
    Banerjee, Subhash
    Brilakis, Emmanouil S.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (06) : 744 - 750
  • [5] PATIENT DOSIMETRY DURING INTERVENTIONAL CARDIAC PROCEDURES IN A DEDICATED CATHETERIZATION LABORATORY
    Uniyal, Satish C.
    Chaturvedi, Vineet
    Sharma, Sunil D.
    Rawat, Anurag
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (02) : 201 - 208
  • [6] Efficacy of Low-Dose Compared With Standard-Dose Radiation for Cardiac Catheterization and Intervention (KAR RAD Study)
    Kar, Subrata
    Teleb, Mohamed
    Albaghdadi, Aymen
    Ibrahim, Ahmed
    Mukherjee, Debabrata
    JOURNAL OF INVASIVE CARDIOLOGY, 2019, 31 (06) : 187 - 194
  • [7] Minimizing scattered radiation dose in cardiac catheterization laboratory during interventional procedures using lead free drape-MILD study
    Bhat, Keshavamurthy Ganapathy
    Guleria, Vivek Singh
    Singla, Manish
    Bohra, Vijay
    Kumar, J. Ratheesh
    Bharadwaj, Prashant
    Datta, Rajat
    Hasija, Pradeep Kumar
    INDIAN HEART JOURNAL, 2022, 74 (03) : 201 - 205
  • [8] Patient effective doses and radiation risks in cardiac catheterization procedures
    Sulieman, A.
    Abdelrazig, A.
    Alkhorayef, M.
    Babikir, E.
    Al-Mohammed, H. I.
    Al-Mugren, K. S.
    Bradley, D.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 157 : 54 - 59
  • [9] Radiation Reduction in Pediatric and Adult Congenital Patients During Cardiac Catheterization
    Mauriello, Daniel A.
    Fetterly, Kenneth A.
    Lennon, Ryan J.
    Reeder, Guy S.
    Taggart, Nathaniel W.
    Hagler, Donald J.
    Cetta, Frank
    Cabalka, Allison K.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (05) : 801 - 808
  • [10] Radiation Dose Benchmarks During Cardiac Catheterization for Congenital Heart Disease in the United States
    Ghelani, Sunil J.
    Glatz, Andrew C.
    David, Sthuthi
    Leahy, Ryan
    Hirsch, Russel
    Armsby, Laurie B.
    Trucco, Sara M.
    Holzer, Ralf J.
    Bergersen, Lisa
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (09) : 1060 - 1069