Unfractionated Heparin Activity Measured by Anti-Factor Xa Levels Is Associated With the Need for Extracorporeal Membrane Oxygenation Circuit/Membrane Oxygenator Change: A Retrospective Pediatric Study

被引:54
|
作者
Irby, Katherine [1 ]
Swearingen, Christopher [2 ]
Byrnes, Jonathan [1 ,3 ]
Bryant, Joshua [4 ]
Prodhan, Parthak [1 ,3 ]
Fiser, Richard [1 ]
机构
[1] Univ Arkansas Med Sci, Coll Med, Dept Pediat, Div Pediat Crit Care, Little Rock, AR 72205 USA
[2] Univ Arkansas Med Sci, Coll Med, Dept Pediat, Div Biostat, Little Rock, AR 72205 USA
[3] Univ Arkansas Med Sci, Coll Med, Dept Pediat, Div Cardiol, Little Rock, AR 72205 USA
[4] Arkansas Childrens Hosp, Little Rock, AR 72202 USA
关键词
anti-Factor Xa; extracorporeal membrane oxygenation; children; heparin; ACTIVATED CLOTTING TIME; COAGULATION MANAGEMENT; RESPIRATORY-FAILURE; ANTICOAGULATION; CIRCULATION; ECMO;
D O I
10.1097/PCC.0000000000000101
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Investigate whether anti-Factor Xa levels are associated with the need for change of circuit/membrane oxygenator secondary to thrombus formation in pediatric patients. Design and Settings: Retrospective single institution study. Patients: Retrospective record review of 62 pediatric patients supported with extracorporeal membrane oxygenation from 2009 to 2011. Interventions: Data on standard demographic characteristics, indications for extracorporeal membrane oxygenation, duration of extracorporeal membrane oxygenation, activated clotting time measurements, anti-Factor Xa measurements, and heparin infusion rate were collected. Generalized linear models were used to associate anti-Factor Xa concentrations and need for change of either entire circuit/membrane oxygenator secondary to thrombus formation. Measurements and Main Results: Sixty-two patients met study inclusion criteria. No-circuit change was required in 45 of 62 patients. Of 62 patients, 17 required change of circuit/membrane oxygenator due to thrombus formation. Multivariate analysis of daily anti-Factor Xa measurements throughout duration of extracorporeal membrane oxygenation support estimated a mean anti-Factor Xa concentration of 0.20 IU/mL (95% CI, 0.16, 0.24) in no-complete-circuit group that was significantly higher than the estimated concentration of 0.13 IU/mL (95% CI, 0.12, 0.14) in complete-circuit group (p = 0.001). A 0.01 IU/mL decrease in anti-Factor Xa increased odds of need for circuit/membrane oxygenator change by 5% (odds ratio = 1.105; 95% CI, 1.00, 1.10; p = 0.044). Based on the observed anti-Factor Xa concentrations, complete-circuit group had 41% increased odds for requiring circuit/membrane oxygenator change compared with no-complete-circuit group (odds ratio = 1.41; 95% CI, 1.01, 1.96; p = 0.044). Mean daily activated clotting time measurement (p = 0.192) was not different between groups, but mean daily heparin infusion rate (p < 0.001) was significantly different between the two groups. Conclusions: Higher anti-Factor Xa concentrations were associated with freedom from circuit/membrane oxygenator change due to thrombus formation in pediatric patients during extracorporeal membrane oxygenation support. Activated clotting time measurements did not differ significantly between groups with or without circuit/membrane oxygenator change. This is the first study to link anti-Factor Xa concentrations with a clinically relevant measure of thrombosis in pediatric patients during extracorporeal membrane oxygenation support. Further prospective study is warranted.
引用
收藏
页码:E175 / E182
页数:8
相关论文
共 23 条
  • [21] Variation in coagulation factor activity levels cause discrepancies between activated partial thromboplastin time and anti-Xa activity for heparin monitoring: a retrospective observational study
    Saito, Tomoyo
    Hayakawa, Mineji
    Kumano, Osamu
    Honma, Yoshinori
    Murashita, Mone
    Kato, Jun
    Fukui, Syouki
    Takahashi, Masaki
    Takahashi, Yuki
    Tsuchida, Takumi
    Mizugaki, Asumi
    Takauji, Shuhei
    Hayamizu, Mariko
    Yoshida, Tomonao
    Katabami, Kenichi
    Wada, Takeshi
    Maekawa, Kunihiko
    JOURNAL OF INTENSIVE CARE, 2023, 11 (01)
  • [22] ACCURACY OF ANTI-FACTOR XA-ACTIVITY DETERMINATION OF UNFRACTIONATED AND LOW-MOLECULAR HEPARIN - A COLLABORATIVE STUDY IN THE FEDERAL-REPUBLIC-OF-GERMANY AND THE FORMER GERMAN-DEMOCRATIC-REPUBLIC
    HARENBERG, J
    SCHLANDER, M
    ARZTLICHE LABORATORIUM, 1991, 37 (02): : 39 - 44
  • [23] Variation in coagulation factor activity levels cause discrepancies between activated partial thromboplastin time and anti-Xa activity for heparin monitoring: a retrospective observational study
    Tomoyo Saito
    Mineji Hayakawa
    Osamu Kumano
    Yoshinori Honma
    Mone Murashita
    Jun Kato
    Syouki Fukui
    Masaki Takahashi
    Yuki Takahashi
    Takumi Tsuchida
    Asumi Mizugaki
    Shuhei Takauji
    Mariko Hayamizu
    Tomonao Yoshida
    Kenichi Katabami
    Takeshi Wada
    Kunihiko Maekawa
    Journal of Intensive Care, 11