Peripheral teflon catheters: Factors determining incidence of phlebitis and duration of cannulation

被引:41
作者
Cornely, OA [1 ]
Bethe, U [1 ]
Pauls, R [1 ]
Waldschmidt, D [1 ]
机构
[1] Univ Cologne Hosp, Dept Internal Med 1, D-50924 Cologne, Germany
关键词
D O I
10.1086/502044
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
BACKGROUND: Catheter-related phlebitis is a frequent problem in the clinical setting. Risk factors for catheter-related phlebitis were assessed at a single tertiary-care institution where no routine change policy for peripheral intravenous catheters is in place. METHODS: In a nonrandomized, observational trial, peripheral intravenous Teflon catheters were inserted in patients with a diagnosis of leukemia, lymphoma, solid tumor, acquired immunodeficiency syndrome, other serious infection, or autoimmune disorder. Underlying disease, age, white blood cell count at the time of insertion, physician placing the catheter, catheter bore, duration of cannulation, reason for removal of the catheter, and visual inspection of the insertion site were recorded. RESULTS: Four hundred twelve catheters were inserted in 175 patients. The number of catheterizations per episode varied between 1 and 7. Three hundred sixty-four (88.3%) catheter placements were evaluable. The mean duration of cannulation was 4.2 days. The overall incidence of phlebitis was 12.9. Catheters in leukopenic patients showed a longer duration of cannulation compared with catheters in nonleukopenic patients, but no difference regarding the phlebitis rate. CONCLUSION: Findings in this study partly contrast with data reported in the literature. In particular, leukopenia, female gender, prolonged duration of cannulation, antibiotics, and choice of insertion site could not be shown to be risk factors (Infect Control Hosp Epidemiol 2002;23:249-253).
引用
收藏
页码:249 / 253
页数:5
相关论文
共 18 条
[11]   SEMIQUANTITATIVE CULTURE METHOD FOR IDENTIFYING INTRAVENOUS-CATHETER-RELATED INFECTION [J].
MAKI, DG ;
WEISE, CE ;
SARAFIN, HW .
NEW ENGLAND JOURNAL OF MEDICINE, 1977, 296 (23) :1305-1309
[12]  
Pearson ML, 1996, INFECT CONT HOSP EP, V17, P438
[13]  
Pearson ML, 1996, AM J INFECT CONTROL, V24, P262
[14]  
TAGER IB, 1983, AM J EPIDEMIOL, V118, P839
[15]   INTRAVENOUS THERAPY TEAM AND PERIPHERAL VENOUS CATHETER ASSOCIATED COMPLICATIONS - A PROSPECTIVE CONTROLLED-STUDY [J].
TOMFORD, JW ;
HERSHEY, CO ;
MCLAREN, CE ;
PORTER, DK ;
COHEN, DI .
ARCHIVES OF INTERNAL MEDICINE, 1984, 144 (06) :1191-1194
[16]   COMPLICATIONS OF INTRAVENOUS THERAPY WITH STEEL NEEDLES AND TEFLON CATHETERS - A COMPARATIVE-STUDY [J].
TULLY, JL ;
FRIEDLAND, GH ;
BALDINI, LM ;
GOLDMANN, DA .
AMERICAN JOURNAL OF MEDICINE, 1981, 70 (03) :702-706
[17]  
VanWijngaerden E, 1997, ACTA CLIN BELG, V52, P9
[18]  
WIDMER A, 1997, SWISS NOSO, V4, P22