A Hybrid Islanding Detection Technique Using Average Rate of Voltage Change and Real Power Shift

被引:173
作者
Mahat, Pukar [1 ]
Chen, Zhe [1 ]
Bak-Jensen, Birgitte [1 ]
机构
[1] Aalborg Univ, Inst Energy Technol, DK-9220 Aalborg, Denmark
关键词
Distributed generation; islanding detection; real power shift; voltage change; PROTECTION; ALGORITHM; STORAGE;
D O I
10.1109/TPWRD.2009.2013376
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The mainly used islanding detection techniques may be classified as active and passive techniques. Passive techniques don't perturb the system but they have larger non-detection zones, whereas active techniques have smaller non-detection zones but they perturb the system. In this paper, a new hybrid technique is proposed to solve this problem. An average rate of voltage change (passive technique) has been used to initiate a real power shift (active technique), which changes the real power of distributed generation (DG), when the passive technique cannot have a clear discrimination between islanding and other events in the system. Simulation results show that the proposed method is effective in detecting islanding of distribution systems with DGs.
引用
收藏
页码:764 / 771
页数:8
相关论文
共 22 条
  • [1] [Anonymous], 2000, 9292000 IEEE
  • [2] [Anonymous], 2003, 1547TM IEEE
  • [3] CASE-STUDY ON THE INTEGRATION OF A NONUTILITY INDUCTION GENERATOR TO THE HYDRO-QUEBEC DISTRIBUTION NETWORK
    BELHOMME, R
    PLAMONDON, M
    NAKRA, H
    DESROSIERS, D
    GAGNON, C
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (03) : 1677 - 1684
  • [4] Intelligent-based approach to islanding detection in distributed generation
    El-Arroudi, Khalil
    Joos, Geza
    Kamwa, Innocent
    McGillis, Donald T.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (02) : 828 - 835
  • [5] Loss-of-mains detection for small generators
    Hopewell, PD
    Jenkins, N
    Cross, AD
    [J]. IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1996, 143 (03): : 225 - 230
  • [6] Automatic phase-shift method for islanding detection of grid-connected photovoltaic inverters
    Hung, GK
    Chang, CC
    Chen, CL
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2003, 18 (01) : 169 - 173
  • [7] Jang S.I, 2004, P IEE INT C DEV POW, V2, P571
  • [8] An islanding detection method for distributed generations using voltage unbalance and total harmonic distortion of current
    Jang, SI
    Kim, KH
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (02) : 745 - 752
  • [9] Jang SI, 2002, 2002 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, P800, DOI 10.1109/PESW.2002.985117
  • [10] KOBAYASHI H, 1991, IEEE PHOT SPEC CONF, P695, DOI 10.1109/PVSC.1991.169299