Gaussian approximation of thermoluminescence (TL) peaks: A common misconception for analysis of TL of persistent luminescent materials

被引:10
|
作者
Chandrasekhar, Ngangbam [1 ]
Gartia, K. [1 ]
机构
[1] Manipur Univ, Dept Phys, Imphal 795003, Manipur, India
关键词
Thermoluminescence (TL); Persistent luminescence; Trap-depth; Analysis of TL; TRAPPING PARAMETER; RED; PHOSPHORESCENCE; DECONVOLUTION; DEPTH; EU2+;
D O I
10.1016/j.jallcom.2018.02.256
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Whenever one over simplifies a physical phenomenon or even any concept, misconceptions are bound to occur. This seems to be true in the case of use of thermoluminescence (TL) in the study of materials by non-specialists. The fact that most semiconducting/insulating materials exhibit TL has led to many publications that ignore the basic rules of use of TL in determining the two key intrinsic trapping parameters, the trap-depth (E) and the frequency factor (s) that control the phenomenon. Manipulation of the value of E and s in a system by suitable activator and co-activator leads to the optimization for specific use of materials. In this work we discuss a common misconception that has been continuously propagated. It is the deconvolution of complex glow curves using Gaussian function and using the component of TL peaks to calculate trap depth (E) by peak shape method. This assumption is questionable and can yield parameters that are physically unrealistic. To prove our point, we consider as many as four phosphors namely ZnS: Cu+ Co2+, CaxSr1-xS:Eu, Sr2MgSi2O7; Eu2+Dy3+ and BaZrSi3O9:Eu2+. (c) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:773 / 778
页数:6
相关论文
共 38 条
  • [1] Thermoluminescence (TL) from photosynthetic materials
    Thomas, S
    Gaikwad, JU
    Vidyasagar, PB
    INDIAN JOURNAL OF BIOCHEMISTRY & BIOPHYSICS, 1999, 36 (05): : 289 - 295
  • [2] Thermoluminescence of persistent luminescent materials
    Gartia, R.K.
    Chandrasekhar, Ngangbam
    Gartia, R.K. (rkgartia12@yahoo.in), 1600, Trans Tech Publications Ltd (357): : 171 - 191
  • [3] Trap spectroscopy and thermoluminescence of persistent luminescent materials
    Singh, Th Basanta
    Mashangva, Magdalene
    Gartia, R. K.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2013, 51 (04) : 223 - 229
  • [4] Analysis of trap distribution of a red persistent luminescent materials using thermoluminescence
    Singh, L. Lovedy
    Singh, S. Nabadwip
    Singh, Th. Ranjan
    Gopal, E.
    LUMINESCENCE, 2020, 35 (07) : 1077 - 1083
  • [5] On the expected order of kinetics in a series of thermoluminescence (TL) and thermally stimulated conductivity (TSC) peaks
    Chen, R.
    Pagonis, V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 312 : 60 - 69
  • [6] A model explaining the inability of exciting thermoluminescence (TL) peaks in certain low temperature ranges
    Lawless, J. L.
    Chen, R.
    Pagonis, V
    RADIATION MEASUREMENTS, 2021, 145
  • [7] Irradiated foods detection by thermoluminescence (TL) and DEFT/APC analysis
    Choi, ID
    Kang, EK
    Yang, JS
    FOOD SCIENCE AND BIOTECHNOLOGY, 2004, 13 (02) : 151 - 155
  • [8] The nature of the electron traps in quartz associated with the thermoluminescence (TL) peaks in the range 70-700K
    Halperin, A
    ANNALES DE CHIMIE-SCIENCE DES MATERIAUX, 1997, 22 (08): : 595 - 600
  • [9] Searching for TL/OSL dose rate effects in various luminescent materials
    Mrozik, Anna
    Bilski, Pawel
    Mandowski, Arkadiusz
    Klosowski, Mariusz
    Budzanowski, Maciej
    Drop, Jagoda
    Swakon, Jan
    Discher, Michael
    RADIATION MEASUREMENTS, 2024, 176
  • [10] Estimation of band gap of muscovite mineral using thermoluminescence (TL) analysis
    Kalita, J. M.
    Wary, G.
    PHYSICA B-CONDENSED MATTER, 2016, 485 : 53 - 59