Optical Fiber Distributed Sensing of Temperature, Thermal Strain and Thermo-Mechanical Force Formations on OPGW Cables under Wind Effects

被引:0
|
作者
Gunday, Abdurrahman [1 ]
Karlik, Sait Eser [2 ]
机构
[1] Uludag Univ, Vocat Sch Orhangazi, Program Elect Technol, TR-16800 Orhangazi, Bursa, Turkey
[2] Uludag Univ, Fac Engn &Architecture, Dept Elect & Elect Engn, TR-16059 Gorukle, Bursa, Turkey
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Optical ground wire (OPGW) is generally used to protect the phase conductors of the overhead power cables from high discharge currents due to lightning strikes and instantaneous current increase due to short-circuits or breakdowns as well as to provide data transmission for telecommunication purposes. OPGW cables are exposed to effects of environmental factors such as wind, rain, humidity and snow as well as cooling/heating effects of short-circuits and instantaneous current increases occurring on the phase conductor. When the OPGW cable is exposed to those effects, deformations occur on the cable insulation in time. In this study, using Raman effect based optical fiber distributed temperature sensing (DTS) method, temperature and thermal strain variations occurring along the OPGW cable due to environmental conditions, in particular wind speed and wind direction, have been analyzed and simulations have been performed. Furthermore, thermo-mechanical forces occurring on the OPGW cable have been expressed as a function of temperature change and Young modulus variations. Temperature and thermal strain dependencies of thermo-mechanical forces have also been derived. Using results of the theoretical analysis, simulations of thermo-mechanical force variations along the sensing fiber have also been performed considering the wind effect. The simulation model has been built up for central loose tube type OPGW cable containing single mode optical fiber operating at 1550 nm. For wind speed variations between 5.3 m/s and 10.3 m/s, minimum temperature detected on the cable varies between 26.86 degrees C and 22.41 degrees C, respectively, minimum thermal strain varies between 184 mu epsilon and 64.67 mu epsilon, respectively. Simulation results show that temperature sensitivities of thermo-mechanical forces are 26 times greater than thermal strain sensitivities.
引用
收藏
页码:462 / +
页数:6
相关论文
共 50 条
  • [1] The impact of temperature and strain formations on young and shear moduli in usage of optical fiber distributed sensing for power cables
    Optik fiberli daǧinik algilamanin yüksek gerilim kablolarindaki kullaniminda sicaklik ve gerginlik oluçumlarinin young ve shear modülleri üzerindeki etkisi
    1600, Gazi Universitesi (29):
  • [2] THE IMPACT OF TEMPERATURE AND STRAIN FORMATIONS ON YOUNG AND SHEAR MODULI IN USAGE OF OPTICAL FIBER DISTRIBUTED SENSING FOR POWER CABLES
    Gunday, Abdurrahman
    Karlik, Sait Eser
    Yilmaz, Gunes
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2014, 29 (03): : 517 - 525
  • [3] Mechanical Properties of Optical Fiber Strain Sensing Cables under γ-Ray Irradiation and Large Strain Influence
    Piccolo, Arianna
    Delepine-Lesoille, Sylvie
    Friedrich, Etienne
    Aziri, Shasime
    Lecieux, Yann
    Leduc, Dominique
    SENSORS, 2020, 20 (03)
  • [4] Optical Fiber Sensing textile for Temperature and Strain Distributed Measurment
    Biondi, Andres M.
    Guo, Xuo
    Zhou, Jingcheng
    Tang, Qixiang
    Ghandi, Harshnareshkumar
    Goplan, Balaji
    Hanna, Thomas
    Ivey, Jackson
    Yu, Tzuyang
    Wang, Xingwei
    Yu, Tzu-Yang
    Gyekenyesi, Andrew L.
    NONDESTRUCTIVE CHARACTERIZATION AND MONITORING OF ADVANCED MATERIALS, AEROSPACE, CIVIL INFRASTRUCTURE, AND TRANSPORTATION XV, 2021, 11592
  • [5] Distributed Optical Fiber Sensing for Wind Blade Strain Monitoring and Defect Detection
    Kaplan, A. M.
    Klute, S. M.
    Gifford, D. K.
    Heaney, A. D.
    STRUCTURAL HEALTH MONITORING 2011: CONDITION-BASED MAINTENANCE AND INTELLIGENT STRUCTURES, VOL 1, 2011, : 394 - 401
  • [6] Effects of temperature and thermo-mechanical couplings on material instabilities and strain localization of inelastic materials
    Benallal, A
    Bigoni, D
    JOURNAL OF THE MECHANICS AND PHYSICS OF SOLIDS, 2004, 52 (03) : 725 - 753
  • [7] Distributed strain and temperature sensing in plastic optical fiber using Rayleigh scatter
    Kreger, Stephen T.
    Sang, Alex K.
    Gifford, Dawn K.
    Froggatt, Mark E.
    FIBER OPTIC SENSORS AND APPLICATIONS VI, 2009, 7316
  • [8] The calibration technology of wind tunnel strain-gage balance under the action of thermo-mechanical coupling
    Miao, Lei
    Ma, Tao
    Xu, Zhiwei
    Xie, Bin
    Zhou, Miwen
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2022, 43 (03): : 153 - 162
  • [9] Analysis of crack behavior in an Epoxy-fiber composite under thermal and thermo-mechanical loading
    Chahraoui, Y.
    Zaoui, B.
    Serier, B.
    Belgherras, M. E.
    Fekirini, H.
    JOURNAL OF NEW TECHNOLOGY AND MATERIALS, 2019, 9 (02) : 35 - 44
  • [10] Thermo-mechanical buckling analysis of thick beams reinforced with agglomerated CNTs with temperature-dependent thermo-mechanical properties under a nonuniform thermal loading
    Kiani, Farhad
    Ariaseresht, Yusef
    Niroumand, Amirhossein
    Afshari, Hassan
    MECHANICS BASED DESIGN OF STRUCTURES AND MACHINES, 2024, 52 (01) : 477 - 497