Separation of a binary mixture of pesticides in fruits using a flow-through optosensor

被引:11
作者
Llorent-Martinez, E. J. [1 ]
Delgado-Blanca, I. [1 ]
Ruiz-Medina, A. [1 ]
Ortega-Barrales, P. [1 ]
机构
[1] Univ Jaen, Fac Expt Sci, Dept Phys & Analyt Chem, E-23071 Jaen, Spain
关键词
SIA; Automation; Plaguicide; MRL; On-line separation; TANDEM MASS-SPECTROMETRY; FLUORESCENCE OPTOSENSOR; MULTIRESIDUE METHOD; EXTRACTION; SYSTEM; CARBENDAZIM; FUNGICIDE; ELECTRODE; RESIDUES; WATERS;
D O I
10.1016/j.talanta.2013.06.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-through optosensor is here proposed for the determination of mixtures of two widely used pesticides, carbendazim and o-phenylphenol, in fruits. The pesticides are separated on-line using an additional amount of solid support, C-18 silica gel, in the flow-through cell. The resolution is performed due to the different retention/desorption kinetics of the analytes when interacting with the C-18 microbeads. Therefore, both separation and determination are integrated in the same cell, considerably simplifying the system. In addition, the use of Sequential Injection Analysis provides a high degree of automation and minimum wastes generation. After the analytes are separated, their native fluorescence is measured, obtaining linearity in the 2.0-30 and 1.1-20 mg kg(-1) ranges for carbendazim and o-phenylphenol. The detection limits are 0.60 and 0.33 mg kg(-1) for carbendazim and o-phenylphenol respectively. The proposed method fulfills the maximum residue limits (MRLs) established in Europe and USA for these pesticides in cherries, pineapple, and mango: 5-10 mg kg(-1). In order to demonstrate the suitability of the method, several samples have been analyzed and the obtained results compared with a chromatographic method. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:462 / 467
页数:6
相关论文
共 43 条
[31]   Development and Validation of a Discriminating Dissolution Method for Atorvastatin Delayed-Release Nanoparticles Using a Flow-Through Cell: A Comparative Study Using USP Apparatus 4 and 1 [J].
Gite, Sandip ;
Chogale, Manasi ;
Patravale, Vandana .
DISSOLUTION TECHNOLOGIES, 2016, 23 (02) :14-20
[32]   Method development and validation of dissolution testing for nicotine release from smokeless tobacco products using flow-through cell apparatus and UPLC-PDA [J].
Miller, John H. ;
Danielson, Tim ;
Pithawalla, Yezdi B. ;
Brown, Anthony P. ;
Wilkinson, Celeste ;
Wagner, Karl ;
Aldeek, Fadi .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1141
[33]   Selective Recovery of Copper(II) from Incineration Ash Produced from a Municipal Waste Incineration Facility Using a Flow-through Type Electrolysis Method [J].
Masanobu Mori ;
Satoshi Honda ;
Daisuke Kozaki .
Analytical Sciences, 2020, 36 :611-615
[34]   High β-O-4 polymeric lignin and oligomeric phenols from flow-through fractionation of wheat straw using recyclable aqueous formic acid [J].
Tian, Guoyu ;
Xu, Jiayun ;
Fu, Yingjuan ;
Guo, Yanzhu ;
Wang, Zhaojiang ;
Li, Qun .
INDUSTRIAL CROPS AND PRODUCTS, 2019, 131 :142-150
[35]   Quantification of gimeracil, tegafur, and 5-FU in human plasma via LC-MS/ MS with a simplified pretreatment using flow-through extraction [J].
Ando, Motozumi ;
Watanabe, Norio ;
Seike, Riko ;
Gocho, Saori ;
Maeda, Shoko ;
Inagaki, Masami ;
Kawahara, Masami .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2025, 1251
[36]   Separation of BTEX from a naphtha feed to ethylene crackers using a binary mixture of [4empy][Tf2N] and [emim][DCA] ionic liquids [J].
Larriba, Marcos ;
Navarro, Pablo ;
Gonzalez, Emilio J. ;
Garcia, Julian ;
Rodriguez, Francisco .
SEPARATION AND PURIFICATION TECHNOLOGY, 2015, 144 :54-62
[37]   Electrochemical removal of gaseous benzene using a flow-through reactor with efficient and ultra-stable titanium suboxide/titanium-foam anode at ambient temperature [J].
Quan, Fengjiao ;
Wu, Bin ;
Guo, Yuxiao ;
Zhang, Xu ;
Shen, Wenjuan ;
Jia, Falong ;
Liu, Xiao ;
Ai, Zhihui ;
Zhang, Lizhi .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2023, 645 :533-541
[38]   In vitro Evaluation of Trimethoprim and Sulfamethoxazole from Fixed-Dose Combination Generic Drugs using Spectrophotometry: Comparison of Flow-Through Cell and USP Paddle Methods [J].
Medina, Raul ;
Miranda, Maximiliano ;
Hurtado, Marcela ;
Dominguez-Ramirez, Adriana M. ;
Reyes, Octavio ;
Ruiz-Segura, Juan C. .
TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2015, 14 (11) :2061-2069
[39]   Recovery of sugars and amino acids from brewers' spent grains using subcritical water hydrolysis in a single and two sequential semi-continuous flow-through reactors [J].
Sganzerla, William Gustavo ;
Vigano, Juliane ;
Castro, Luiz Eduardo Nochi ;
Maciel-Silva, Francisco Weshley ;
Rostagno, Mauricio A. ;
Mussatto, Solange I. ;
Forster-Carneiro, Tania .
FOOD RESEARCH INTERNATIONAL, 2022, 157
[40]   Study on the Dissolution Behavior of UO2 in the Na2CO3-H2O2 System Using a Flow-Through Dissolution Device [J].
Zhang, Meng ;
Fang, Haofan ;
He, Mingjian ;
Jiao, Caishan ;
Zhao, Hongtao ;
Shang, Chaobo .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2024, 63 (50) :21662-21671