Separation of a binary mixture of pesticides in fruits using a flow-through optosensor

被引:11
|
作者
Llorent-Martinez, E. J. [1 ]
Delgado-Blanca, I. [1 ]
Ruiz-Medina, A. [1 ]
Ortega-Barrales, P. [1 ]
机构
[1] Univ Jaen, Fac Expt Sci, Dept Phys & Analyt Chem, E-23071 Jaen, Spain
关键词
SIA; Automation; Plaguicide; MRL; On-line separation; TANDEM MASS-SPECTROMETRY; FLUORESCENCE OPTOSENSOR; MULTIRESIDUE METHOD; EXTRACTION; SYSTEM; CARBENDAZIM; FUNGICIDE; ELECTRODE; RESIDUES; WATERS;
D O I
10.1016/j.talanta.2013.06.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-through optosensor is here proposed for the determination of mixtures of two widely used pesticides, carbendazim and o-phenylphenol, in fruits. The pesticides are separated on-line using an additional amount of solid support, C-18 silica gel, in the flow-through cell. The resolution is performed due to the different retention/desorption kinetics of the analytes when interacting with the C-18 microbeads. Therefore, both separation and determination are integrated in the same cell, considerably simplifying the system. In addition, the use of Sequential Injection Analysis provides a high degree of automation and minimum wastes generation. After the analytes are separated, their native fluorescence is measured, obtaining linearity in the 2.0-30 and 1.1-20 mg kg(-1) ranges for carbendazim and o-phenylphenol. The detection limits are 0.60 and 0.33 mg kg(-1) for carbendazim and o-phenylphenol respectively. The proposed method fulfills the maximum residue limits (MRLs) established in Europe and USA for these pesticides in cherries, pineapple, and mango: 5-10 mg kg(-1). In order to demonstrate the suitability of the method, several samples have been analyzed and the obtained results compared with a chromatographic method. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:462 / 467
页数:6
相关论文
共 42 条
  • [1] Novel sequential separation and determination of a quaternary mixture of fungicides by using an automatic fluorimetric optosensor
    Delgado-Blanca, I.
    Ruiz-Medina, A.
    Ortega-Barrales, P.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2019, 36 (02): : 278 - 288
  • [2] A novel flow-through fluorescence optosensor for the determination of thiabendazole
    Piccirilli, G. N.
    Escandar, G. M.
    ANALYTICA CHIMICA ACTA, 2007, 601 (02) : 196 - 203
  • [3] A novel flow-through fluorescence optosensor for the sensitive determination of tetracycline
    Shen, Li-Ming
    Chen, Ming-Li
    Chen, Xu-Wei
    TALANTA, 2011, 85 (03) : 1285 - 1290
  • [4] A photochemically induced fluorescence based flow-through optosensor for screening of nitenpyram residues in cruciferous vegetables
    Jimenez-Lopez, Julia
    Ortega-Barrales, Pilar
    Ruiz-Medina, Antonio
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2018, 35 (05): : 941 - 949
  • [5] Microfluidic Flow-through SPME Chip for Online Separation and MS Detection of Multiple Analyses in Complex Matrix
    Chen, Yujun
    Gong, Tao
    Yu, Cilong
    Qian, Xiang
    Wang, Xiaohao
    MICROMACHINES, 2020, 11 (02)
  • [6] Hot Compressed Water Extraction of Lignin by Using a Flow-Through Reactor
    Machmudah, Siti
    Wahyudiono
    Kanda, Hideki
    Sasaki, Mitsuru
    Goto, Motonobu
    ENGINEERING JOURNAL-THAILAND, 2015, 19 (04): : 25 - 44
  • [7] Ultrafast DNA Amplification Using Microchannel Flow-Through PCR Device
    Lin, Yen-Heng
    Liao, Xiang-Jun
    Chang, Wei
    Chiou, Chiuan-Chian
    BIOSENSORS-BASEL, 2022, 12 (05):
  • [8] Dual frequency dielectrophoresis with interdigitated sidewall electrodes for microfluidic flow-through separation of beads and cells
    Wang, Lisen
    Lu, Jente
    Marukenko, Steven A.
    Monuki, Edwin S.
    Flanagan, Lisa A.
    Lee, Abraham P.
    ELECTROPHORESIS, 2009, 30 (05) : 782 - 791
  • [9] Analysis of Agroalimentary and Environmental Contaminants Using Flow-Through Chemical Optosensors
    Llorent-Martinez, E. J.
    Fernandez-de Cordova, M. L.
    Ortega-Barrales, P.
    Ruiz-Medina, A.
    APPLIED SPECTROSCOPY REVIEWS, 2015, 50 (07) : 527 - 556
  • [10] Electrochemical Measurements of Glucose Using a Micro Flow-Through Immobilized Enzyme Reactor
    Facchini Cerqueira, Marcos Rodrigues
    Angnes, Lucio
    Matos, Renato Camargo
    ELECTROANALYSIS, 2017, 29 (05) : 1474 - 1480