Three-dimensional numerical simulation of a failed coronary stent implant at different degrees of residual stenosis. Part II: Apparent viscosity and wall permeability

被引:4
作者
Boghi, Andrea [1 ]
Di Venuta, Ivan [2 ]
Gori, Fabio [2 ]
机构
[1] Cranfield Univ, Sch Water Energy & Agrifood, Cranfield, Beds, England
[2] Univ Roma Tor Vergata, Dept Ind Engn, Via Politecn 1, I-00133 Rome, Italy
关键词
EVANS BLUE-DYE; SHEAR-STRESS; FLUID-DYNAMICS; PULSATILE FLOW; BLOOD-FLOW; HEMODYNAMICS; ACCUMULATION; BIFURCATION; ARTERIES; ALBUMIN;
D O I
10.1080/10407782.2017.1293976
中图分类号
O414.1 [热力学];
学科分类号
摘要
The influence of the degree of residual stenosis (DOR) on the hemodynamics inside coronary arteries is investigated through three-dimensional (3D) numerical simulations. The vascular wall permeability is investigated and the effect of the non-Newtonian viscosity discussed. The results agree in predicting an abrupt increase in wall permeability above 45% DOR, indicating that the implant could lead to a massive restenosis. This behavior is considered to be due to the shift of the regions involved by low and oscillatory wall shear stress (WSS), from the zone adjacent to the struts toward the center of the stent meshes.
引用
收藏
页码:653 / 665
页数:13
相关论文
共 44 条
[1]   AORTIC ENDOTHELIAL PERMEABILITY TO ALBUMIN - FOCAL AND REGIONAL PATTERNS OF UPTAKE AND TRANSMURAL DISTRIBUTION OF I-131 ALBUMIN IN YOUNG PIG [J].
BELL, FP ;
ADAMSON, IL ;
SCHWARTZ, CJ .
EXPERIMENTAL AND MOLECULAR PATHOLOGY, 1974, 20 (01) :57-68
[2]  
Berne R. M., 1967, LEVY CARDIOVASCULAR
[3]   Numerical Simulation of Blood Flow through Different Stents in Stenosed and Non-Stenosed Vessels [J].
Boghi, Andrea ;
Gori, Fabio .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2015, 68 (03) :225-242
[4]   High throughput en face mapping of arterial permeability using tile scanning confocal microscopy [J].
Clarke, Lindsey A. ;
Mohri, Zahra ;
Weinberg, Peter D. .
ATHEROSCLEROSIS, 2012, 224 (02) :417-425
[5]   FLOW-MEDIATED ENDOTHELIAL MECHANOTRANSDUCTION [J].
DAVIES, PF .
PHYSIOLOGICAL REVIEWS, 1995, 75 (03) :519-560
[6]   Three-dimensional numerical simulation of a failed coronary stent implant at different degrees of residual stenosis. Part I: Fluid dynamics and shear stress on the vascular wall [J].
Di Venuta, Ivan ;
Boghi, Andrea ;
Gori, Fabio .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2017, 71 (06) :638-652
[7]   Effects of stent geometry on local flow dynamics and resulting platelet deposition in an in vitro model [J].
Duraiswamy, Nandini ;
Cesar, Jose M. ;
Schoephoerster, Richard T. ;
Moore, James E., Jr. .
BIORHEOLOGY, 2008, 45 (05) :547-561
[8]   Morphological predictors of restenosis after coronary stenting in humans [J].
Farb, A ;
Weber, DK ;
Kolodgie, FD ;
Burke, AP ;
Virmani, R .
CIRCULATION, 2002, 105 (25) :2974-2980
[9]  
Fournier R.L., 1999, BASIC TRANSPORT PHEN
[10]   EQUILIBRIUM AND KINETIC PROPERTIES OF EVANS BLUE-ALBUMIN SYSTEM [J].
FREEDMAN, FB ;
JOHNSON, JA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1969, 216 (03) :675-+