A GPU-Based Pencil Beam Algorithm for Dose Calculations in Proton Radiation Therapy

被引:0
作者
Kalantzis, Georgios [1 ]
Leventouri, Theodora [1 ]
Tachibana, Hidenobu [2 ]
Shang, Charles [3 ]
机构
[1] Florida Atlantic Univ, Dept Phys, Boca Raton, FL 33431 USA
[2] Natl Canc Ctr Hosp East, Kashiwa, Chiba 2778577, Japan
[3] Lynn Canc Inst, Boca Raton, FL 33486 USA
来源
SOFTWARE ENGINEERING, ARTIFICIAL INTELLIGENCE, NETWORKING AND PARALLEL/DISTRIBUTED COMPUTING 2015 | 2016年 / 612卷
关键词
Pencil-beam; Proton therapy; GPU; Dose calculations; TREATMENT PLANNING SYSTEM; ANALYTICAL APPROXIMATION; RADIOTHERAPY; IMPLEMENTATION; DISTRIBUTIONS; GEOMETRY; MODEL;
D O I
10.1007/978-3-319-23509-7_2
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Recent developments in radiation therapy have been focused on applications of charged particles, especially-protons. Proton therapy can allow higher dose conformality compared to conventional radiation therapy. Dose calculations have an integral role in the successful application of proton therapy. Over the years several dose calculation methods have been proposed in proton therapy. A common characteristic of all these methods is their extensive computational burden. One way to ameliorate that issue is the parallelization of the algorithm. Graphics processing units (GPUs) have recently been employed to accelerate the proton dose calculation process. Pencil-beam dose calculation algorithms for proton therapy have been widely utilized in clinical routine for treatment planning purposes in most clinical settings, due to their simplicity of calculation scheme and acceptable accuracy. In the current study a GPU-based pencil beam algorithm for dose calculations with protons is proposed. The studies indicated a maximum speedup factor of similar to 127 in a homogeneous phantom.
引用
收藏
页码:17 / 29
页数:13
相关论文
共 50 条
  • [41] An analytic linear accelerator source model for GPU-based Monte Carlo dose calculations
    Tian, Zhen
    Li, Yongbao
    Folkerts, Michael
    Shi, Feng
    Jiang, Steve B.
    Jia, Xun
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (20) : 7941 - 7967
  • [42] Commissioning of pencil beam and Monte Carlo dose engines for non-isocentric treatments in scanned proton beam therapy
    Carlino, A.
    Boehlen, T.
    Vatnitsky, S.
    Grevillot, L.
    Osorio, J.
    Dreindl, R.
    Palmans, H.
    Stock, M.
    Kragl, G.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (17)
  • [43] Online Adaptive Proton Therapy Facilitated by Artificial Intelligence-Based Autosegmentation in Pencil Beam Scanning Proton Therapy
    Feng, Hongying
    Shan, Jie
    Vargas, Carlos E.
    Keole, Sameer R.
    Rwigema, Jean-Claude M.
    Yu, Nathan Y.
    Ding, Yuzhen
    Zhang, Lian
    Hu, Yanle
    Schild, Steven E.
    Wong, William W.
    Vora, Sujay A.
    Shen, Jiajian
    Liu, Wei
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2025, 121 (03): : 822 - 831
  • [44] Experimental validation of a 4D dose calculation routine for pencil beam scanning proton therapy
    Pfeiler, Tina
    Baeumer, Christian
    Engwall, Erik
    Geismar, Dirk
    Spaan, Bernhard
    Timmermann, Beate
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (02): : 121 - 133
  • [45] Point dose comparison of Monte Carlo and pencil beam algorithms in treatment planning system for proton therapy
    Monkongsubsin, Wiroon
    Keawsamur, Mintra
    Sanghangthum, Taweap
    Ayuthaya, Isra Israngkul Na
    [J]. HEALTH AND TECHNOLOGY, 2024,
  • [46] Feasibility of CBCT-based proton dose calculation using a histogram-matching algorithm in proton beam therapy
    Arai, Kazuhiro
    Kadoya, Noriyuki
    Kato, Takahiro
    Endo, Hiromitsu
    Komori, Shinya
    Abe, Yoshitomo
    Nakamura, Tatsuya
    Wada, Hitoshi
    Kikuchi, Yasuhiro
    Takai, Yoshihiro
    Jingu, Keiichi
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 33 : 68 - 76
  • [47] A New Pencil Beam Model for Photon Dose Calculations
    Zhang, Pengcheng
    Shu, Huazhong
    Simon, Antoine
    Haigron, Pascal
    De Crevoisier, Renaud
    [J]. PROCEEDINGS OF THE 2013 6TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2013), VOLS 1 AND 2, 2013, : 428 - 432
  • [48] Dosimetric validation of a GPU-based dose engine for a fast in silico patient-specific quality assurance program in light ion beam therapy
    Magro, Giuseppe
    Fassi, Martina
    Mirandola, Alfredo
    Rossi, Eleonora
    Molinelli, Silvia
    Russo, Stefania
    Bazani, Alessia
    Vai, Alessandro
    Ciocca, Mario
    Donetti, Marco
    Mairani, Andrea
    [J]. MEDICAL PHYSICS, 2022, 49 (12) : 7802 - 7814
  • [49] GPU-based Image Pyramid Transform Algorithm
    Huang Chengman
    Liu Qiang
    Li Yuxia
    [J]. ADVANCED MATERIALS IN MICROWAVES AND OPTICS, 2012, 500 : 422 - 427
  • [50] Evaluation of an a priori scatter correction algorithm for cone-beam computed tomography based range and dose calculations in proton therapy
    Andersen, Andreas Gravgaard
    Park, Yang-Kyun
    Elstrom, Ulrik Vindelev
    Petersen, Jorgen Breede Baltzer
    Sharp, Gregory C.
    Winey, Brian
    Dong, Lei
    Muren, Ludvig Paul
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 16 : 89 - 94